文献速递关节外科

基于PACS与iPhone的新型数字模板法在全髋关节置换术中的准确性:与数字化放射影像上醋酸酯模板法的比较

Accuracy of a New Digital Templating Method for Total Hip Arthroplasty Using Picture Archiving and Communication System (PACS) and iPhone Technology: Comparison With Acetate Templating on Digital Radiography.
PubMed 文献 · J Arthroplasty · 2021-01-15

本研究回顾性对113张髋关节X线片由三名观察者进行模板测量,比较PACS联合iPhone的数字模板法与醋酸酯模板覆盖法的准确性及可重复性。

要点

  • 数字模板法预测股骨柄和偏心距±1号的准确性显著优于醋酸酯模板法。
  • 两种方法预测髋臼杯和颈长±1号的准确性无显著差异。
  • 两种方法均具有高度至几乎完美的观察者内和观察者间可重复性。

核心结论

  • 使用PACS和iPhone的数字模板法对无骨水泥全髋关节置换术植入物尺寸的预测是准确且可重复的。

研究设计与样本

  • 回顾性研究,共纳入113张髋关节X线片,由三名观察者分别进行数字模板法和混合模板法测量。

主要发现

  • 两种方法观察者内和观察者间信度均为高度至几乎完美一致。

临床怎么用

  • 在无骨水泥全髋关节置换术前,可采用PACS联合iPhone的数字模板法进行植入物尺寸预测,其股骨柄和偏心距预测准确性优于传统醋酸酯模板法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Preoperative templating for total hip arthroplasty (THA) on digital radiography can be achieved using templating software or hybrid methods (acetate templates overlaid on digital images). No studies have examined templating with a mobile phone. We evaluated the accuracy and reproducibility of a new digital templating method using the picture archiving and communication system (PACS) and iPhone, compared with the hybrid method for cementless THA. METHODS: A total of 113 hip radiographs were retrospectively templated by three observers. For the digital method, a circle was drawn on the acetabulum using PACS to represent the cup. The photograph of the computer screen was taken with an iPhone and imported into the Keynote presentation software. The femoral stem was then templated with transparent digital templates, which had been digitized from acetate templates. For the hybrid method, an acetate template was placed over the onscreen digital radiographs. Templated results were compared with the actual components used. RESULTS: The digital method was more accurate than the hybrid method to predict ±1 size of femoral stem [93.8% (106 hips) vs 84.1% (95 hips), P = .032] and offset [90.3% (102 hips) vs 75.2% (85 hips), P = .004)]. The accuracies of digital and hybrid techniques were comparable with predict ±1 size for acetabular cup [92.9% (105 hips) vs 89.4% (101 hips), P = .483] and neck length [98.2% (111 hips) vs 96.5% (109 hips), P = .683]. Both techniques had substantial to almost perfect agreement for intraobserver and interobserver reliability. CONCLUSION: Digital templating using PACS and iPhone is accurate and reproducible for predicting implant size of cementless THA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pongkunakorn A, Aksornthung C, Sritumpinit N, et al. Accuracy of a New Digital Templating Method for Total Hip Arthroplasty Using Picture Archiving and Communication System (PACS) and iPhone Technology: Comparison With Acetate Templating on Digital Radiography. J Arthroplasty. 2021. PMID: 33583670. doi:10.1016/j.arth.2021.01.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。