文献速递关节外科

维生素E infused 非骨水泥单块髋臼杯的多中心前瞻性队列研究:生存率与患者报告结局

Survivorship and Patient-Reported Outcomes of an Uncemented Vitamin E-Infused Monoblock Acetabular Cup: A Multicenter Prospective Cohort Study.
PubMed 文献 · J Arthroplasty · 2020-12-26

这项多中心前瞻性队列研究在9家医疗机构招募675例患者,评估维生素E infused 高交联聚乙烯髋臼杯的中长期结局,最终450例完成末次随访。Harris髋关节评分及疼痛与满意度视觉模拟评分在各时间点均改善并维持,髋臼杯8年9个月生存率为98.9%,未因无菌性松动行翻修。

要点

  • 维生素E infused 髋臼杯在中长期随访中患者报告结局持续改善。
  • 髋臼杯8年9个月生存率为98.9%,未因无菌性松动翻修。
  • 随访期间未见髋臼骨溶解,仅1例发现透亮线。

核心结论

  • 维生素E infused 聚乙烯髋臼杯在中长期随访中患者报告结局、影像学指标及髋臼杯生存率均令人满意。

研究设计与样本

  • 多中心前瞻性队列研究,在9家医疗机构招募675例患者,最终450例可完成末次评估。
  • 数据收集时间点为术前、术后6至12周、6个月、1年、2年及5年,髋臼杯生存数据随访至术后8年9个月。

主要发现

  • Harris髋关节评分以及疼痛和满意度视觉模拟评分在所有时间点均有改善,并在整个随访期间维持。
  • 89%的髋臼杯植入于Lewinnek安全区内。
  • 1例发现透亮线,随访期间未观察到髋臼骨溶解。
  • 髋臼杯8年9个月生存率为98.9%,未观察到因无菌性松动行翻修。

关键数值与推荐

  • 髋臼杯8年9个月生存率为98.9%。
  • 89%的髋臼杯植入于Lewinnek安全区内。

临床怎么用

  • 对于接受全髋关节置换术的患者,可考虑使用维生素E infused 聚乙烯髋臼杯,其中长期患者报告结局和影像学表现良好。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Addition of vitamin E to polyethylene is theorized to reduce the potential for oxidative wear in acetabular components. This paper presents a multicenter prospective cohort study that reports on outcomes from use of a Vitamin E-infused highly cross-linked polyethylene acetabular cup. METHODS: Patients were recruited across nine medical institutions. Clinical outcome measures recorded were the Harris Hip Score, visual analogue score for pain and satisfaction. Evidence of implant loosening or osteolysis was collected radiologically. Cup survival and reasons for revision in relevant cases were also recorded. Data collection was undertaken preoperatively, at 6-12 weeks, 6 months, 1 year, 2 years, and 5 years. A total of 675 patients were recruited, with 450 cases available at final review. Data regarding cup survival was available to 8 years and 9 months postoperatively. RESULTS: Improvements in both the Harris Hip Score and visual analogue score for pain and satisfaction were recorded at all time points, with these being maintained through the length of follow-up. In total, 89% of cups were implanted within the Lewinnek safe zone. A lucent line was identified in one case, with no evidence of acetabular osteolysis observed throughout the follow-up period. Cup survival was 98.9% at 8 years and 9 months. No revisions for aseptic loosening were observed. CONCLUSIONS: The use of a vitamin E-infused polyethylene acetabular cup demonstrates reassuring patient-reported outcomes, radiological measures, and cup survival at medium to long-term follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Mahmood FF, Beck M, de Gast A, et al. Survivorship and Patient-Reported Outcomes of an Uncemented Vitamin E-Infused Monoblock Acetabular Cup: A Multicenter Prospective Cohort Study. J Arthroplasty. 2020. PMID: 33516632. doi:10.1016/j.arth.2020.12.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。