文献速递关节外科

减少手术器械负担可提高全关节置换术手术室效率并降低围手术期成本

Minimizing Surgical Instrument Burden Increases Operating Room Efficiency and Reduces Perioperative Costs in Total Joint Arthroplasty.
PubMed 文献 · J Arthroplasty · 2021-01-21

结果显示,全膝关节置换术中仅45.5%的器械被使用,优化后87件器械中移除28件(32.2%);全髋关节置换术中仅36.0%的器械被使用,优化后112件器械中移除46件(41.1%)。器械准备时间缩短,灭菌过程节省时间,年均节省成本达281,298.05美元。

要点

  • 全膝关节置换术中仅45.5%的器械被使用,优化后移除32.2%的器械。
  • 全髋关节置换术中仅36.0%的器械被使用,优化后移除41.1%的器械。
  • 精益方法优化器械托盘可提高效率并年均节省281,298.05美元。

核心结论

  • 精益方法可用于消除全关节置换术中冗余或使用不足的器械,提高手术效率并产生显著的成本节省。

研究设计与样本

  • 采用精益方法,由外科医生识别冗余或使用不足的器械,并商定每个托盘所需的最少器械数量。
  • 分析托盘修改前后的器械利用率及处理时间,基于每件器械0.59至11.52美元的处理因子计算年度成本节省。

主要发现

  • 全膝关节置换术中打开的器械仅45.5%被使用。
  • 全膝关节置换术优化后,87件器械中移除28件(32.2%),剩余器械可存储于一个托盘中。
  • 全膝关节置换术平均准备时间从20.7分钟降至14.2分钟,灭菌过程节省40至75分钟。
  • 全髋关节置换术中仅36.0%的器械被使用。
  • 全髋关节置换术优化后,112件器械中移除46件(41.1%),托盘数量减少至2个;平均准备时间从27.9分钟降至18.6分钟,处理过程节省45至150分钟。

关键数值与推荐

  • 全膝关节置换术器械利用率为45.5%,优化后移除28/87件(32.2%)器械。
  • 全髋关节置换术器械利用率为36.0%,优化后移除46/112件(41.1%)器械。
  • 全膝关节置换术平均准备时间从20.7分钟降至14.2分钟,灭菌过程节省40至75分钟。
  • 全髋关节置换术平均准备时间从27.9分钟降至18.6分钟,处理过程节省45至150分钟。
  • 年均节省成本为281,298.05美元。

临床怎么用

  • 骨科智能体医生可参考精益方法评估全关节置换术器械托盘,识别并移除冗余或使用不足的器械。
  • 优化器械托盘可缩短准备和灭菌时间,提高手术室效率,并降低围手术期成本。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Optimizing surgical trays to improve operating room efficiency and reduce costs in instrument processing is an under-appreciated strategy for cost containment. This study aimed to assess the economic impact of instrument tray optimization in total joint arthroplasty. METHODS: Thirty-five randomly selected elective primary total knee arthroplasty and total hip arthroplasty performed by 4 fellowship-trained surgeons were analyzed. Type and number of instruments used as well as timing of different steps in the sterilization process were recorded by an independent observer. Using Lean methodology, surgeons identified redundant or underutilized instruments and agreed upon the fewest number needed for each tray. Instrument utilization rates and processing time were analyzed before and after tray modifications. Annual cost savings were calculated based on a processing factor of $0.59-$11.52 per instrument. RESULTS: Only 45.5% of instruments opened for total knee arthroplasty were utilized. After optimization, 28 of 87 (32.2%) instruments were removed and the remainder could be stored in one tray. Mean set-up time decreased from 20.7 to 14.2 minutes, while 40-75 minutes were saved during the sterilization process. For total hip arthroplasty, only 36.0% of instruments were utilized. Using Lean methods, 46 of 112 (41.1%) instruments were removed and tray count was reduced to 2 trays. Mean set-up time decreased from 27.9 to 18.6 minutes, while 45-150 minutes were saved during processing. Average annual savings amounted to $281,298.05. CONCLUSION: Lean methodology can be used to eliminate redundant or underutilized instruments in total joint arthroplasty, improving surgical efficiency and generating substantial cost savings.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Lonner JH, Goh GS, Sommer K, et al. Minimizing Surgical Instrument Burden Increases Operating Room Efficiency and Reduces Perioperative Costs in Total Joint Arthroplasty. J Arthroplasty. 2021. PMID: 33579631. doi:10.1016/j.arth.2021.01.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。