不同植入系统保留原髌骨对翻修全膝关节置换术中髌骨轨迹的影响
本研究回顾性分析293例无菌性翻修全膝关节置换术(rTKA)患者,比较保留原髌骨与翻修系统同一制造商(SIM)或不同制造商(DIM)对髌骨轨迹的影响。结果显示两组术后髌骨倾斜和Insall-Salvati比无显著差异,DIM组外侧平移较大但去除侧别影响后无差异。结论认为保留固定良好的原髌骨并使用不同翻修系统未观察到临床显著的髌骨轨迹差异。
要点
- 保留原髌骨并使用不同制造商翻修系统未导致临床显著的髌骨轨迹差异。
- DIM组外侧平移较大,但校正侧别后差异无统计学意义。
- 若原髌骨固定良好,rTKA中可考虑保留以避免骨丢失和骨折风险。
核心结论
- 保留原髌骨并使用不同翻修植入系统时,未观察到临床显著的髌骨轨迹差异。
研究设计与样本
- 回顾性队列研究,纳入2011年8月至2019年6月单中心293例无菌性rTKA患者,分为SIM组(122例)和DIM组(171例)。
主要发现
- 两组人口学特征无差异。
- 术前和术后髌骨倾斜及Insall-Salvati比差异无统计学意义。
- DIM组外侧髌骨平移更大(-0.01 ± 6.09 vs 2.68 ± 7.61 mm,P = .001),但校正侧别后平移幅度无差异(0.06 ± 3.69 vs 0.52 ± 4.95 mm,P = .394)。
关键数值与推荐
- 髌骨倾斜和Insall-Salvati比无显著差异。
- 外侧平移原始值DIM组更大(P = .001),但校正后无差异(P = .394)。
临床怎么用
- 翻修全膝关节置换术中,若原髌骨固定良好,可保留原髌骨而不必更换,无论翻修系统是否不同。
局限性
- 回顾性研究设计,证据等级为III级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patellar maltracking is a potential surgical complication following total knee arthroplasty (TKA) and can result in anterior knee pain, recurrent patellar dislocation, and damage to the medial patellar soft tissue stabilizers. Data remain unclear as to whether the patellar button should be revised during a revision TKA (rTKA) if changing the component implant system. Our study examines whether retaining the original patellar button during an rTKA using a different implant system affects patellar tracking. METHODS: A retrospective cohort study of rTKA patients between August 2011 and June 2019 was performed at an urban, tertiary referral center. Patients were divided into 2 cohorts depending on whether their retained patella from their primary TKA was of the same (SIM) or different implant manufacturer (DIM) as the revision system used. Radiographic measurements were performed on preoperative and postoperative knee radiographs and differences were compared between the 2 groups. Baseline demographic data were also collected. RESULTS: Of the 293 consecutive, aseptic rTKA cases identified, 122 underwent revision in the SIM cohort and 171 in the DIM cohort. There were no demographic differences between the groups. No statistical significance was calculated for differences in preoperative and postoperative patellar tilt or Insall-Salvati ratio between the groups. The DIM group was found to have more lateral patellar translation (-0.01 ± 6.09 vs 2.68 ± 7.61 mm, P = .001). However, when calculating differences in the magnitude of the translation (thereby removing differences due to laterality), no difference was observed (0.06 ± 3.69 vs 0.52 ± 4.95 mm, P = .394). CONCLUSION: No clinically significant differences in patellar tracking were observed when the original patellar component was retained and a different revision implant system was used. Given the inherent risks of bone loss and fracture with patellar component revision, surgeons performing rTKA may retain the primary patella if it is well fixed and can still expect appropriate patellar tracking regardless of the revision implant system used. LEVEL OF EVIDENCE: III, Retrospective cohort study.
引用
- Yeroushalmi D, Zak S, Sharan M, et al. Patellar Tracking in Revision Total Knee Arthroplasty: Does Retaining a Patella From a Different Implant System Matter? J Arthroplasty. 2021. PMID: 33612328. doi:10.1016/j.arth.2021.01.082
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。