骨水泥粘度与初次全膝关节置换术后翻修风险的关联
基于Kaiser Permanente全关节置换登记系统的队列研究,纳入76052例因骨关节炎行全骨水泥固定初次全膝关节置换术的患者,比较中粘度骨水泥与高粘度骨水泥的翻修风险。中粘度骨水泥组相比高粘度骨水泥组任何翻修风险更低(HR=0.82,95%CI=0.70-0.95),但无菌性松动翻修风险无差异(HR=0.80,95%CI=0.56-1.13)。
要点
- 中粘度骨水泥较高粘度骨水泥任何翻修风险更低(HR=0.82)。
- 两组无菌性松动翻修风险无显著差异(HR=0.80,95%CI=0.56-1.13)。
- 高粘度骨水泥广泛使用,需进一步研究其他品牌及失败机制。
核心结论
- 使用Simplex中粘度骨水泥相比Palacos高粘度骨水泥,任何翻修风险更低,但无菌性松动翻修风险无差异。
研究设计与样本
- 回顾性队列研究,使用Kaiser Permanente全关节置换登记系统2001-2018年数据,纳入76052例因骨关节炎行全骨水泥固定初次全膝关节置换术的患者,仅限后稳定固定平台型3种高用量植入系统,采用倾向评分加权Cox回归分析。
主要发现
- 中粘度骨水泥组占41.1%,粗14年累计翻修概率中粘度组4.55%、高粘度组5.12%。
- 倾向评分加权Cox模型中,中粘度骨水泥组任何翻修风险低于高粘度组(HR=0.82,95%CI=0.70-0.95)。
- 无菌性松动翻修风险两组无差异(HR=0.80,95%CI=0.56-1.13)。
临床怎么用
- 在选择骨水泥时,可考虑中粘度骨水泥以降低任何翻修风险,但需结合具体临床情况。
局限性
- 仅比较了Palacos高粘度骨水泥和Simplex中粘度骨水泥,结论不能推广至其他品牌。
- 未发现无菌性松动翻修差异,提示高粘度骨水泥失败机制可能涉及松动以外原因。
- 观察性研究可能存在残余混杂。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Recent case series have reported early failure with the use of high-viscosity cement (HVC) in total knee arthroplasty (TKA). We evaluated revision risk after TKA with HVC compared with medium-viscosity cement (MVC) in a large cohort. METHODS: We conducted a cohort study using data from Kaiser Permanente's Total Joint Replacement Registry. Patients who underwent fully cemented primary TKA for osteoarthritis were identified (2001-2018). Only posterior-stabilized, fixed-mobility designs of the 3 highest-volume implant systems (DePuy PFC, Zimmer NexGen, and Zimmer Persona) were included to mitigate confounding from implant characteristics. Palacos (Zimmer/Heraeus) and Simplex (Stryker) cements comprised the HVC and MVC exposure groups, respectively. Propensity score-weighted Cox proportional hazards regression was used to evaluate risk for any revision during follow-up and risk for revision from aseptic loosening specifically. RESULTS: The final cohort comprised 76,052 TKAs, 41.1% using MVC. The crude 14-year cumulative revision probability was 4.55% and 5.12% for TKA with MVC and HVC, respectively. In propensity score-weighted Cox models, MVC compared with HVC had a lower risk of any revision (hazard ratio = 0.82, 95% confidence interval = 0.70-0.95) while no difference was observed for revision from aseptic loosening (hazard ratio = 0.80, 95% confidence interval = 0.56-1.13). CONCLUSION: While we observed a lower risk for any revision with the use of Simplex MVC compared with Palacos HVC, we did not observe a difference in revision for aseptic loosening specifically. Given the widespread use of HVC, additional research to investigate other HVC and potential mechanisms for failure outside of loosening is warranted. LEVEL OF EVIDENCE: Level III.
引用
- Wyatt RWB, Chang RN, Royse KE, et al. The Association Between Cement Viscosity and Revision Risk After Primary Total Knee Arthroplasty. J Arthroplasty. 2021. PMID: 33610408. doi:10.1016/j.arth.2021.01.052
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。