翻修全膝关节置换中内外翻限制型假体的六年临床随访
单中心回顾性分析194例使用内外翻限制型(VVC)假体的翻修全膝关节置换,最终168例平均随访6年。6年无菌性松动翻修生存率93%,任何原因翻修生存率76%,再手术生存率74%;假体周围感染是最常见再翻修原因(65%)。
要点
- VVC翻修TKA 6年无菌性松动翻修生存率93%,任何原因翻修生存率76%。
- 假体周围感染是最常见再翻修原因,占65%。
核心结论
- VVC翻修TKA选择性使用cone可获得合理结果,6年无菌性松动翻修生存率93%。
- 鉴于影像学进展性改变发生率及6年再手术生存率74%,需长期随访评估耐久性。
研究设计与样本
- 单中心回顾性研究,2005年8月至2018年2月共194例VVC翻修TKA,最终168例平均随访6年。
主要发现
- 6年无菌性松动翻修生存率93%,任何原因翻修生存率76%,再手术生存率74%。
- 股骨假体影像学进展性改变占19%,胫骨假体占16%。
- 再翻修最常见原因为假体周围感染(65%)。
关键数值与推荐
- 除1例外均使用柄;胫骨cone使用率48%,股骨cone使用率19%。
- 股骨AORI分型:1型57例,2A型33例,2B型62例,3型16例;胫骨AORI分型:1型42例,2A型29例,2B型81例,3型16例。
临床怎么用
- 对翻修TKA骨缺损患者可考虑VVC假体并选择性使用cone。
- 对AORI 3型、年龄<65岁及影像学进展性改变患者应加强随访。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is scant literature evaluating varus-valgus constrained (VVC) prostheses in contemporary revision total knee arthroplasty (TKA). Therefore, we aimed to evaluate the durability of VVC revision TKA with selective use of cones. METHODS: A retrospective review of 194 revision TKAs with VVC was performed from August 2005 through February 2018 at a single institution. The final cohort consisted of 168 TKAs with a mean follow-up of 6 years. Stems were used in all but 1 TKA, tibial cones in 48%, and femoral cones in 19%. Anderson Orthopaedic Research Institute classification in femurs was 1 in 57, 2A in 33, 2B in 62, 3 in 16, and in tibias, 1 in 42, 2A in 29, 2B in 81, and 3 in 16. RESULTS: Survival analysis showed that 93% were free of revision for aseptic component loosening, 76% were free of revision for any reason, and 74% were free of reoperation at 6 years. Anderson Orthopaedic Research Institute 3 femur or tibia, age <65 years, and progressive radiographic changes were associated with an increased risk of revision for aseptic loosening (P < .05). Progressive radiographic changes were seen in 19% of femoral and 16% of tibial constructs. The most common reason for re-revision was periprosthetic joint infection (65%). CONCLUSION: VVC revision TKA with selective use of cones provided a reasonable outcome as 93% were free of revision for aseptic loosening at 6 years. However, given the rate of patients with progressive radiographic changes and survivorship free of reoperation of 74% at 6 years, long-term follow-up will help assess the durability of these constructs.
引用
- Hernandez NM, Hinton ZW, Wu CJ, et al. Varus-Valgus Constrained Implants in Revision Total Knee Arthroplasty: Mean Clinical Follow-Up of Six Years. J Arthroplasty. 2020. PMID: 33558046. doi:10.1016/j.arth.2020.12.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。