文献速递关节外科

预防性胫骨柄降低严重内翻畸形初次全膝关节置换术后早期无菌性松动率

A Prophylactic Tibial Stem Reduces Rates of Early Aseptic Loosening in Patients with Severe Preoperative Varus Deformity in Primary Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2021-01-23

本研究匹配分析术前内翻畸形>8度的初次全膝关节置换患者,比较带柄与标准胫骨组件的无菌性松动率。带柄组术前畸形更重且使用更多限制性假体,但放射透亮线进展率和无菌性松动率均更低。预防性使用胫骨柄可能有助于提高假体生存率。

要点

  • 术前内翻>8度患者使用胫骨柄可降低无菌性松动率(0% vs 5.15%)。
  • 带柄组放射透亮线进展>2mm的比例更低(5.97% vs 17.6%)。
  • 带柄组术前畸形更重且更多使用限制性假体,仍显示获益。

核心结论

  • 对于术前严重内翻畸形患者,尽管畸形更重且限制性假体使用率更高,使用胫骨柄仍可降低无菌性松动率。
  • 预防性使用胫骨柄可能有助于提高这类患者的假体生存率。

研究设计与样本

  • 回顾性匹配队列研究,带柄胫骨组件组67例与标准胫骨组件组134例按1:2匹配。
  • 纳入标准为术前内翻畸形>8度且至少随访2年。

关键数值与推荐

  • 术前内翻畸形>8度定义为严重畸形。
  • 失败定义为因胫骨组件无菌性松动而翻修。
  • 放射透亮线采用膝关节学会放射学评价系统在术后6周、1年、2年测量。

临床怎么用

  • 对术前内翻畸形>8度的初次全膝关节置换患者,可考虑预防性使用胫骨柄以降低早期无菌性松动风险。
  • 需综合考虑畸形程度和限制性假体使用需求,个体化决定是否使用胫骨柄。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients with a preoperative varus deformity >8 degrees are at increased risk of aseptic loosening after total knee arthroplasty. This study analyzes the effect of a tibial stem on the rate of aseptic loosening in patients with a severe preoperative varus deformity. METHODS: Patients with a preoperative varus deformity of >8 degrees and 2-year minimum follow-up with a stemmed tibial component (n = 67) were matched 1:2 to patients with a similar preoperative varus deformity with a standard tibial component (n = 134). Radiolucent lines were measured on the tibia at 6 weeks, 1 year, and 2 years postoperatively using the Knee Society Radiographic Evaluation System. Failure was defined as revision due to aseptic loosening of the tibial component. Outcomes were evaluated using Student's t-tests and log-rank tests. RESULTS: Patients with tibial stems had greater preoperative deformity (12.9 vs 11.3 degrees, P = .004). There was no difference in postoperative alignment (1.7 vs 2.1 degrees varus, P = .25) or tibial component angle (1.8 vs 2.1 degrees varus, P = .33). Patients with stems were more likely to have more constraint (44.8% vs 1.5%, P < .001). Progression of radiolucent lines >2 mm was observed in 17.6% (23/134) vs 5.97% (4/67) of patients in the stem group (P = .03). Rates of aseptic loosening were lower in the stem group (0% vs 5.15%, P = .05). CONCLUSION: Despite worse preoperative deformity and higher utilization of constraint, tibial stem use in patients with severe preoperative varus deformity resulted in lower rates of aseptic loosening. Prophylactic use of stems in these patients may help increase implant survival.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hegde V, Bracey DN, Brady AC, et al. A Prophylactic Tibial Stem Reduces Rates of Early Aseptic Loosening in Patients with Severe Preoperative Varus Deformity in Primary Total Knee Arthroplasty. J Arthroplasty. 2021. PMID: 33583669. doi:10.1016/j.arth.2021.01.049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。