文献速递关节外科

EOS成像在全髋关节置换术前模板测量中准确且可重复

EOS Imaging is Accurate and Reproducible for Preoperative Total Hip Arthroplasty Templating.
PubMed 文献 · J Arthroplasty · 2020-10-08

EOS对髋臼和股骨假体型号完全匹配率分别为71%和66%,98%病例误差在一个型号内,均优于常规影像(P<.05);观察者间一致性优秀。

要点

  • EOS模板测量髋臼和股骨假体型号完全匹配率分别为71%和66%,98%病例误差在一个型号内。
  • EOS对假体型号的准确匹配优于常规影像(P<.05),股骨柄偏心距预测准确率83% vs 80%(P=.341)。
  • 观察者间一致性优秀(髋臼Cronbach's alpha=0.94,股骨0.96),且不受年龄、性别、侧别或BMI影响。

核心结论

  • EOS成像用于全髋关节置换术前模板测量准确,观察者间一致性优秀。

主要发现

  • EOS模板预测髋臼和股骨假体型号完全匹配率分别为71%和66%,98%病例误差在一个型号内。
  • EOS对髋臼和股骨假体型号完全匹配的预测优于常规影像(P<.05)。
  • 股骨偏心距预测准确率EOS为83%,常规模板为80%(P=.341)。
  • 假体型号和偏心距不受患者年龄、性别、侧别或BMI影响。
  • 观察者间一致性优秀:髋臼Cronbach's alpha=0.94,股骨Cronbach's alpha=0.96。

临床怎么用

  • EOS成像可作为全髋关节置换术前模板测量的准确工具,且辐射剂量低于传统X线。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Templating is a critical part of preoperative planning for total hip arthroplasty (THA). The accuracy of templating on images acquired with EOS is unknown. This study sought to compare the accuracy and reproducibility of templating for THA using EOS imaging to conventional digital radiographs. METHODS: Forty-three consecutive primary unilateral THAs were retrospectively templated, six months postoperatively, using preoperative 2D EOS imaging and conventional radiographs. Two blinded observers templated each case for acetabular and femoral component size and femoral offset. The retrospectively templated sizes were compared to the sizes selected during surgery. Interobserver agreement was calculated, and the influence of demographic variables was explored. RESULTS: EOS templating predicted the exact acetabular and femoral size in 71% and 66% of cases, respectively, and to within one size in 98% of cases. The acetabular and femoral component size was more likely to be templated to the exact size using EOS compared to conventional imaging (P < .05). The femoral component offset choice was accurately predicted in 83% of EOS cases compared to 80% of conventional templates (P = .341). Component size and offset were not influenced by patient age, gender, laterality, or BMI. Interobserver agreement was excellent for acetabular (Cronbach's alpha = 0.94) and femoral (Cronbach's alpha = 0.96) component size. CONCLUSIONS: Preoperative templating for THA using EOS imaging is accurate, with an excellent interobserver agreement. EOS exposes patients to less radiation than traditional radiographs, and its three-dimensional applications should be explored as they may further enhance preoperative plans.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Buller LT, McLawhorn AS, Maratt JD, et al. EOS Imaging is Accurate and Reproducible for Preoperative Total Hip Arthroplasty Templating. J Arthroplasty. 2020. PMID: 33616064. doi:10.1016/j.arth.2020.09.051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。