延长粗隆截骨下特定细芯活动型抗生素髋关节间隔器的高骨折率
该回顾性研究纳入58例置入Zimmer-Biomet StageOne Select股骨间隔器(ZBSO)的患者,比较是否行延长粗隆截骨(ETO)的结局。结论认为ZBSO在ETO情况下表现类似手工/模制间隔器,骨折率高,应谨慎联用。
要点
- ZBSO间隔器整体骨折率8.6%,ETO组骨折率25.0%,无ETO组仅2.3%。
- ZBSO在ETO情况下应谨慎使用,因其细芯设计导致高骨折风险。
核心结论
- ZBSO间隔器总体并发症率与既往间隔器系列相似,但在ETO情况下骨折率高达25%,应谨慎联用。
研究设计与样本
- 回顾性 review 纳入63例置入ZBSO的患者,排除5例后分析58例,按是否行ETO分组比较。
主要发现
- 58例中5例(8.6%)发生间隔器骨折。
- 患者人口学特征或ETO长度与间隔器骨折无关联。
- 2例(3.4%)发生假体周围骨折,4例(6.9%)发生脱位。
临床怎么用
- 在计划行ETO的两阶段翻修中,应避免使用ZBSO间隔器或警惕其高骨折风险。
局限性
- 回顾性设计,样本量较小(58例),可能存在选择偏倚和随访限制。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Two-stage revision remains the standard of care for prosthetic joint infection after total hip arthroplasty. However, there are substantial complications associated with articulating antibiotic hip spacers. Handmade and molded spacers have been shown to have higher rates of spacer fracture than antibiotic-coated prostheses (ACPs). The aim of this study is to review outcomes with an implant that is often categorized as an ACP spacer, the Zimmer-Biomet StageOne Select Femoral Spacer (ZBSO). METHODS: A retrospective review was performed of 63 patients who underwent placement of a ZBSO. Patients were compared based on whether or not an extended trochanteric osteotomy (ETO) was performed using Fisher's exact and t-tests. RESULTS: Five patients were excluded due to lack of follow-up or death shortly after stage 1 surgery, leaving 58 patients. Spacer fracture was noted in 5 of 58 patients (8.6%). Sixteen patients underwent ETO and 25.0% suffered a spacer fracture compared to 2.3% without ETO (odds ratio 13.7, P = .0248). There was no association between patient demographics or ETO length and spacer fracture. Two patients had periprosthetic fractures (3.4%) and 4 had dislocations (6.9%). Forty-nine patients (84.4%) went on to second-stage revision; of those 26.5% failed to clear the infection and required an average of 2.2 additional surgeries. CONCLUSION: The ZBSO spacer has overall complication rates similar to previously reported spacer series. Although the ZBSO looks like an ACP spacer, in the setting of ETO, it behaves like a molded or handmade spacer with a high rate of spacer fracture (25%) due to the small diameter of the core. This implant should be used with caution in combination with an ETO.
引用
- Lancaster AJ, Carlson VR, Pelt CE, et al. High Rates of Spacer Fracture in the Setting of Extended Trochanteric Osteotomy With a Specific Thin-Core Articulating Antibiotic Hip Spacer. J Arthroplasty. 2021. PMID: 33632579. doi:10.1016/j.arth.2021.01.086
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。