文献速递运动医学关节外科创伤骨科

胫骨高位截骨矫正后倾角与内翻对ACL缺损及重建膝关节运动学和移植物受力的生物力学影响

Effect of Slope and Varus Correction High Tibial Osteotomy in the ACL-Deficient and ACL-Reconstructed Knee on Kinematics and ACL Graft Force: A Biomechanical Analysis.
PubMed 文献 · Am J Sports Med · 2020-12-03

该尸体研究选取10例胫骨后倾角增大且轻度内翻的膝关节,模拟10°前闭合楔形截骨及额外5°内翻矫正,在ACL缺损与重建状态下测试四种对线条件。结果显示,联合内翻与后倾角矫正可降低胫骨前移及ACL移植物张力,支持将胫骨平台垂直化作为ACL功能不全(尤其翻修)的治疗目标。

要点

  • 联合内翻与后倾角矫正可降低ACL缺损及重建膝关节的胫骨前移。
  • 联合截骨使ACL移植物受力在200N下平均降低33%,400N下降低58%。
  • 孤立内翻矫正会增加ACL缺损膝关节的胫骨前移,应避免单独使用。

核心结论

  • 联合内翻与后倾角矫正可显著降低ACL缺损及重建尸膝的胫骨前移和ACL移植物受力,支持胫骨平台垂直化作为ACL功能不全的治疗目标。

研究设计与样本

  • 对照实验室研究,选取10例经CT测量确认后倾角增大(9.9°±1.4°)且轻度内翻(MPTA 86.5°±2.1°)的尸体膝关节(年龄47.7±5.8岁)。

主要发现

  • ACL缺损膝中,孤立内翻矫正使胫骨前移增加4.3±4.0 mm(P=.04),孤立后倾角减小使胫骨前移减少6.2±4.3 mm(P<.001)。
  • ACL重建膝中,联合内翻与后倾角矫正后胫骨前移较原生对线降低3.7±2.6 mm(P=.01)。
  • 胫骨内旋在内翻矫正后无显著改变,但孤立后倾角矫正后增加4.0°±4.1°(P<.01)。
  • 联合内翻与后倾角截骨使ACL移植物受力在200 N下平均降低33%、400 N下降低58%(P<.001)。

临床怎么用

  • 对ACL功能不全尤其翻修病例,可考虑联合内翻与后倾角矫正以降低胫骨前移和移植物张力。
  • 避免在ACL缺损膝中单独行内翻矫正截骨,因其可能增加胫骨前移。

局限性

  • 研究为尸体生物力学实验,样本量10例,结论需临床研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Correction of high posterior tibial slope is an important treatment option for revision of anterior cruciate ligament (ACL) failure as seen in clinical and biomechanical studies. In cases with moderate to severe medial compartment arthritis, an additional varus correction osteotomy may be added to improve alignment. PURPOSE: To investigate the influence of coronal and sagittal correction high tibial osteotomy in ACL-deficient and ACL-reconstructed knees on knee kinematics and ACL graft load. STUDY DESIGN: Controlled laboratory study. METHODS: Ten cadaveric knees were selected according to previous computed tomography measurements with increased native slope and slight varus tibial alignment (mean ± SD): slope, 9.9°± 1.4°; medial proximal tibia angle, 86.5°± 2.1°; age, 47.7 ± 5.8 years. A 10° anterior closing-wedge osteotomy, as well as an additional 5° of simulated varus correction osteotomy, were created and fixed using an external fixator. Four alignment conditions-native, varus correction, slope correction, and combined varus and slope correction-were randomly tested in 2 states: ACL-deficient and ACL-reconstructed. Compressive axial loads were applied to the tibia while mounted on a free-moving X-Y table and free-rotating tibia in a knee testing fixture. Three-dimensional motion tracking captured anterior tibial translation (ATT) and internal tibial rotation. Change of tensile forces on the reconstructed ACL graft were recorded. RESULTS: In the ACL-deficient knee, an isolated varus correction led to a significant increase of ATT by 4.3 ± 4.0 mm (P = .04). Isolated slope reduction resulted in the greatest decrease of ATT by 6.2 ± 4.3 mm (P < .001). In the ACL-reconstructed knee, ATT showed comparable changes, while combined varus and slope correction led to lower ATT by 3.7 ± 2.6 mm (P = .01) than ATT in the native alignment. Internal tibial rotation was not significantly altered by varus correction but significantly increased after isolated slope correction by 4.0°± 4.1° (P < .01). Each isolated or combined osteotomy showed decreased forces on the graft as compared with the native state. The combined varus and slope osteotomy led to a mean decrease of ACL graft force by 33% at 200 N and by 58% at 400 N as compared with the native condition (P < .001). CONCLUSION: A combined varus and slope correction led to a relevant decrease of ATT in the ACL-deficient and ACL-reconstructed cadaveric knee. ACL graft forces were significantly decreased after combined varus and slope correction. Thus, our biomechanical findings support the treatment goal of a perpendicular-aligned tibial plateau for ACL insufficiencies, especially in cases of revision surgery. CLINICAL RELEVANCE: This study shows the beneficial knee kinematics and reduced forces on the ACL graft after combined varus and slope correction.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Imhoff FB, Comer B, Obopilwe E, et al. Effect of Slope and Varus Correction High Tibial Osteotomy in the ACL-Deficient and ACL-Reconstructed Knee on Kinematics and ACL Graft Force: A Biomechanical Analysis. Am J Sports Med. 2020. PMID: 33270464. doi:10.1177/0363546520976147

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。