文献速递关节外科

前稳定型与保留交叉韧带衬垫在全膝关节置换术中的中期结果与生存率比较

Midterm Outcomes and Survivorship of Anterior Stabilized Versus Cruciate Retaining Bearing in Primary Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-10-07

该回顾性研究比较了3323例(4164膝)初次全膝关节置换术中使用前稳定型(AS)衬垫与保留交叉韧带(CR)衬垫的中期结果。

要点

  • AS衬垫在临床和功能评分改善及生存率上优于CR衬垫。
  • AS组MUA发生率显著高于CR组(8.2% vs 5.9%)。
  • AS组10年无菌生存率98.3%,CR组92.3%。

核心结论

  • AS衬垫在全膝关节置换术中显示出更高的临床和功能评分改善以及更优的生存率。
  • 使用AS衬垫的膝关节MUA发生率更高。

研究设计与样本

  • 回顾性综述,纳入2010年至2014年所有使用同一膝关节系统的初次全膝关节置换术,CR股骨组件相同,配以AS或CR衬垫,最低随访2年,最终队列3323例患者(4164膝)。

主要发现

  • AS组1471膝(35%),CR组2693膝(65%),平均随访5.4年。
  • AS组在膝关节活动度、KSS临床评分、KSS功能评分和KSS疼痛评分改善上显著更高。
  • AS组全因失败、无菌性失败、不稳定翻修和孤立性聚乙烯磨损翻修均显著更少。

临床怎么用

  • 对于适合的患者,可考虑使用AS衬垫以改善临床和功能结果及生存率。
  • 需注意AS衬垫与更高的MUA发生率相关,应加强术后康复管理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There has been increasing utilization of ultracongruent bearings with a cruciate retaining (CR) femoral component in primary total knee arthroplasty. The purpose of this study is to compare outcomes and survivorship between an ultracongruent anterior stabilized (AS) and CR bearing. METHODS: A retrospective review was performed from 2010 through 2014 of all primary total knee arthroplasties with a single knee systems identical CR femur and AS or CR bearing with minimum 2-year follow-up yielding a study cohort of 3323 patients (4164 knees). Knee range of motion, Knee Society pain scores, Knee Society clinical scores, Knee Society functional scores, and University of California Los Angeles activity scores were evaluated. The need for manipulation under anesthesia (MUA), nonrevision surgery and revisions were assessed. RESULTS: AS bearing was used in 1471 knees (35%) and CR bearing used in 2693 knees (65%). Mean follow-up was 5.4 years. The AS group had significantly higher improvements in knee range of motion, Knee Society clinical, Knee Society functional, and Knee Society pain scores. MUAs were performed on 120 knees (8.2%) in the AS group compared with 158 knees (5.9%) in the CR group (P = .005). The AS group had significantly less all-cause failure, aseptic failures, revisions for instability, and revisions for isolated polyethylene wear. The 10-year aseptic survival for AS was 98.3% and for 92.3% for the CR group (P = .002). CONCLUSION: These mid-term results demonstrate the AS bearing had significantly higher improvements in clinical and functional outcomes as well as greater survivorship. Knees in which an AS bearing was used did have a higher incidence of MUA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Law JI, Hurst JM, Morris MJ, et al. Midterm Outcomes and Survivorship of Anterior Stabilized Versus Cruciate Retaining Bearing in Primary Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 33268208. doi:10.1016/j.arth.2020.09.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。