旋转铰链型假体全膝关节置换术后无菌性松动的危险因素:病例对照研究
本研究评估了1235例使用旋转铰链型假体行初次全膝关节置换术的患者,其中33例因无菌性松动行翻修手术,与30例无需翻修的患者进行比较。结果显示较高的体重指数与翻修相关,多数无菌性松动为股骨假体松动,且膝关节近端20 cm处股骨内径(正位片>19 mm)对预测翻修具有较高敏感性和特异性。
要点
- 较高体重指数与旋转铰链型假体全膝关节置换术后翻修相关。
- 无菌性松动多数表现为股骨假体松动。
- 膝关节近端20 cm处股骨内径>19 mm(正位片)预测翻修敏感性91%、特异性87%。
核心结论
- 较高的体重指数与旋转铰链型假体全膝关节置换术后翻修相关。
- 多数无菌性松动患者为股骨假体松动。
- 膝关节近端20 cm处股骨内径(正位和侧位片)可预测无菌性松动患者的翻修。
- 正位片股骨内径>19 mm预测翻修的敏感性为91%,特异性为87%。
研究设计与样本
- 病例对照研究,评估了1235例在本中心使用旋转铰链型假体行初次全膝关节置换术的患者记录。
- 根据纳入和排除标准进一步评估了125例翻修患者,其中33例因无菌性松动翻修,与30例无需翻修手术的患者进行比较。
- 所有数据包括影像学测量均来自初次全膝关节置换术前的记录。
- 证据等级为预后III级。
主要发现
- 较高的体重指数与翻修相关。
- 多数无菌性松动患者为股骨假体松动。
- 膝关节近端20 cm处股骨内径(正位和侧位图像)可预测无菌性松动患者的翻修。
- 正位片股骨内径>19 mm预测翻修的敏感性为91%,特异性为87%。
关键数值与推荐
- 正位片股骨内径>19 mm预测无菌性松动患者需翻修手术的敏感性为91%,特异性为87%。
临床怎么用
- 对于使用旋转铰链型假体行初次全膝关节置换术的患者,应关注体重指数及术前股骨内径测量。
- 正位片股骨内径>19 mm可能提示较高的翻修风险,需加强术后随访。
局限性
- 本研究为病例对照研究,证据等级为预后III级。
- 样本量较小,仅33例无菌性松动翻修患者和30例对照。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Successful results have been reported in association with the use of a rotating-hinge prosthesis for primary total knee arthroplasty (TKA). The objective of the present study was to identify risk factors for aseptic loosening in patients who underwent primary TKA with rotating-hinge knee prostheses. METHODS: The records of 1,235 patients who underwent primary TKA with a rotating-hinge prosthesis at our center were evaluated. A total of 125 patients who underwent revision were further evaluated according to the inclusion and exclusion criteria, and 33 patients who underwent revision because of aseptic loosening were then compared with a group of 30 patients who did not require revision surgery. All data, including radiographic measurements, were obtained from records prior to the primary TKA. RESULTS: On the basis of our review of demographic, anthropometric, clinical, surgical, and radiographic findings, we found that higher body mass index (BMI) was associated with revision. The majority of patients with aseptic loosening had loosening of the femoral component. Furthermore, the inner femoral diameter at 20 cm proximal to the knee joint (on both anteroposterior and lateral images) was found to be predictive of revision among those with aseptic loosening. Receiver operating characteristic curve analysis showed that an inner diameter of the femur of >19 mm on anteroposterior images had a sensitivity of 91% and specificity of 87% for predicting the need for revision surgery in patients with aseptic loosening. CONCLUSIONS: This is one of few studies that has focused on determining risk factors for the failure of rotating-hinge prostheses following TKA surgery. Our findings indicate that a novel variable, the inner (diaphyseal) diameter of the femur at the point 20 cm proximal to the knee joint, is an extremely reliable predictor of revision surgery in patients with aseptic loosening. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
- Levent A, Suero EM, Gehrke T, et al. Risk Factors for Aseptic Loosening After Total Knee Arthroplasty with a Rotating-Hinge Implant: A Case-Control Study. J Bone Joint Surg Am. 2021. PMID: 33369984. doi:10.2106/JBJS.20.00788
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。