Delta陶瓷对陶瓷轴承THA后关节噪音对生活质量影响甚微
该研究回顾了456例非骨水泥全髋关节置换术(THA)使用第四代陶瓷对陶瓷(CoC)轴承的连续病例,对存活357髋在术后11.1±0.7年进行临床评估。结果显示10年假体生存率94.2%,100髋(28%)报告关节噪音,但多数对生活质量影响轻微。多因素分析发现关节噪音发生率随年龄和BMI增加而降低,32mm头较36mm头发生率更低。
要点
- CoC THA术后10年关节噪音发生率约28%,多数影响轻微。
- 年龄和BMI增加、32mm头(vs 36mm)与噪音发生率降低相关。
- 大号头虽改善活动度但可能增加噪音风险,年轻活跃患者需注意。
核心结论
- CoC THA术后10年约28%髋关节报告关节噪音,但对大多数患者生活质量影响可忽略。
研究设计与样本
- 回顾性连续病例系列,456例非骨水泥CoC THA,最终评估357髋,平均随访11.1±0.7年。
主要发现
- 10年生存率:髋臼杯96.3%,股骨柄96.5%,所有组件94.2%。
- Forgotten Joint Score为79±26,Oxford Hip Score为16±7。
- 关节噪音对生活质量平均影响评分1.8±2.9,可忽略60髋(16%),中度27髋(7%),重度仅13髋(4%)。
临床怎么用
- 对于年轻活跃患者,选择36mm头虽可降低脱位风险但需权衡关节噪音风险增加。
- 术后随访中应关注关节噪音对生活质量的潜在影响,尤其在高风险患者中。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL). METHODS: From a series of 456 CoC THAs, there were 25 revisions, 38 deceased, and 36 lost to follow-up. The remaining 357 hips were assessed at 11.1 ± 0.7 years (range, 10-14) using the Forgotten Joint Score, Oxford Hip Score, and a questionnaire on articular noises. Kaplan-Meier survival was calculated, and multivariable analysis was performed to determine associations between articular noise and patient/surgical factors. RESULTS: The 10-year survival was 96.3% for the cup, 96.5% for the stem, and 94.2% for all components. The Forgotten Joint Score was 79 ± 26 (range, 0-100), and Oxford Hip Score was 16 ± 7 (range, 12-60). The mean impact of articular noises on QoL was 1.8 ± 2.9 (range, 0-9): considered negligible in 60 hips (16%), moderate in 27 hips (7%), and severe in only 13 hips (4%). Multivariable analyses revealed that the incidence of articular noise decreased with age (odds ratio [OR], 0.94; P = .001), body mass index (OR, 0.85; P = .001), and in hips implanted with 32-mm (vs 36 mm) heads (OR, 0.18; P = .030). CONCLUSION: Of 100 hips (28%) that reported some articular noises 10 years after CoC THA, the impact of articular noises on QoL was negligible for most patients. Although larger heads can improve mobility and reduce risks of dislocations, surgeons must be aware that increasing head size could also increase risks of articular noises, notably in young and active patients.
引用
- Chatelet JC, Fessy MH, Saffarini M, et al. Articular Noise After THA Using Delta CoC Bearings Has Little Impact on Quality of Life. J Arthroplasty. 2020. PMID: 33293173. doi:10.1016/j.arth.2020.11.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。