文献速递关节外科

同一患者后稳定型与超适形全膝关节置换术后关节感知比较

Comparison of Joint Perception Between Posterior-Stabilized and Ultracongruent Total Knee Arthroplasty in the Same Patient.
PubMed 文献 · J Bone Joint Surg Am · 2021-01-01

这项前瞻性随机对照试验纳入50例同日双侧全膝关节置换患者,一侧用后稳定型假体、另一侧用超适形假体。术后2年,超适形组前后松弛度更大(4.5 mm对1.8 mm,p<0.001)、股骨后滚更少(4.2 mm对9.0 mm,p<0.001),但两组关节感知总体相似,仅超适形组噪音产生更少(18%对38%,p=0.026)。

要点

  • 超适形假体前后松弛度大于后稳定型(4.5 mm对1.8 mm,p<0.001)。
  • 后稳定型假体股骨后滚大于超适形(9.0 mm对4.2 mm,p<0.001)。
  • 两组关节感知总体相似,超适形组噪音更少(18%对38%,p=0.026)。

核心结论

  • 术后2年两组关节感知相似,但超适形组噪音产生更少且矢状面松弛度更大、股骨后滚更少。

研究设计与样本

  • 前瞻性随机对照试验,纳入50例同日双侧全膝关节置换患者,一侧用Persona后稳定型假体、另一侧用超适形假体,术后2年评估。

主要发现

  • 超适形组前后松弛度4.5 mm,后稳定型组1.8 mm(p<0.001)。
  • 超适形组股骨后滚4.2 mm,后稳定型组9.0 mm(p<0.001)。
  • Knee Society Score与WOMAC评分组间无显著差异(所有p>0.05)。
  • 超适形组噪音产生18%,后稳定型组38%(p=0.026)。
  • 侧别偏好、满意度及Forgotten Joint Score组间无差异(所有p>0.05)。

关键数值与推荐

  • 超适形组前后松弛度4.5 mm,后稳定型组1.8 mm(p<0.001)。
  • 超适形组股骨后滚4.2 mm,后稳定型组9.0 mm(p<0.001)。
  • 超适形组噪音产生18%,后稳定型组38%(p=0.026)。

临床怎么用

  • 两种假体术后2年关节感知相似,选择时可综合考虑超适形假体噪音更少但矢状面松弛度更大的特点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Posterior-stabilized and ultracongruent designs are 2 common examples of posterior cruciate ligament-substituting total knee arthroplasty (TKA) prostheses. There is a lack of evidence regarding joint perception differences between ultracongruent and posterior-stabilized TKA. The purpose of this study was to compare the postoperative knee stability, function, and joint perception between ultracongruent and posterior-stabilized TKA in the same patients in order to determine whether there was a difference based on design. METHODS: This prospective, randomized controlled trial included 50 patients who underwent same-day bilateral TKA utilizing Persona (Zimmer Biomet) posterior-stabilized implants in 1 knee (posterior-stabilized group) and ultracongruent implants in the other knee (ultracongruent group). At 2 years postoperatively, patients were evaluated for knee stability, function, and joint perception. Postoperative static knee anteroposterior stability and femoral rollback were compared. Knee function was evaluated with use of the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Joint perception was compared by evaluating noise generation, side preference, satisfaction, and the Forgotten Joint Score. RESULTS: The ultracongruent group had more knee anteroposterior laxity (4.5 mm compared with 1.8 mm in the posterior-stabilized group; p < 0.001) and less femoral rollback (4.2 mm compared with 9.0 mm in the posterior-stabilized group; p < 0.001). Knee Society Score and WOMAC scores were not significantly different between groups (all p > 0.05). Although the ultracongruent group showed less noise generation than the posterior-stabilized group (18% compared with 38%, respectively; p = 0.026), there were no differences in side preference, satisfaction, or Forgotten Joint Score (all p > 0.05). CONCLUSIONS: Both groups had similar joint perception 2 years postoperatively, with obvious differences in noise generation and more sagittal laxity with less femoral rollback in the ultracongruent group. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Kim MS, Koh IJ, Kim CK, et al. Comparison of Joint Perception Between Posterior-Stabilized and Ultracongruent Total Knee Arthroplasty in the Same Patient. J Bone Joint Surg Am. 2021. PMID: 33259430. doi:10.2106/JBJS.20.00279

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。