钛植入物在全膝关节置换术中更优吗?一项随机对照研究

Is a Titanium Implant for Total Knee Arthroplasty Better? A Randomized Controlled Study.
PubMed 文献 · J Arthroplasty · 2020-11-12

结果显示钛植入物更轻(133.9 g vs 390.1 g,P < .01),但临床评分、患者偏好、步态分析、活动度及疼痛均无显著差异,约70%患者未感知钛植入物更轻;钛组放射透亮线发生率为9%,钴铬组为19%。

要点

  • 钛植入物比钴铬植入物轻约三分之二(133.9 g vs 390.1 g,P < .01),但约70%患者未感知更轻。
  • 两组临床评分、患者偏好、步态分析、活动度和疼痛均无显著差异。
  • 钛组放射透亮线发生率为9%,低于钴铬组的19%。

核心结论

  • 较轻的钛植入物相比钴铬植入物未显示出任何临床获益,其轻量不足以产生可感知的差异。
  • 钛植入物显示出比钴铬植入物更低的放射透亮线发生率。

研究设计与样本

  • 平均随访5.3年(范围1-7年)。

主要发现

  • 钛植入物重量为133.9 g,钴铬植入物为390.1 g,钛比钴铬轻三分之一(P < .01)。
  • 临床评分和患者偏好(轻便感、舒适度、自然感、满意度)无显著差异。
  • 约70%患者未感知钛植入物更轻。
  • 步态分析、活动度和疼痛程度无显著差异。
  • 放射透亮线在钛植入物组见于9%,在钴铬植入物组见于19%。

临床怎么用

  • 钛植入物在临床结局上与钴铬植入物相当,不能仅因轻量优势而优先选择钛植入物。
  • 钛植入物可能降低放射透亮线发生率,但需结合长期随访综合评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Lighter weight and lower modulus are potential advantages of titanium (Ti) implants over cobalt chrome (CoCr) implants in total knee arthroplasty (TKA). This study was conducted to determine whether Ti implants in TKA resulted in better clinical outcomes and radiologic results. METHODS: One hundred and eight patients (216 knees) with knee arthritis warranting bilateral primary TKA were randomly allocated to undergo Ti rotating-platform TKA in one knee and CoCr rotating-platform TKA in the contralateral knee. The mean follow-up period was 5.3 years (range, 1-7 years). The weight of Ti implants was one-third lighter than that of CoCr implants (133.9 g vs 390.1 g, P < .01). Clinical outcomes were evaluated using clinical scores, patient preferences (lightness, comfort, naturalness, and satisfaction), gait analysis (kinetic and kinematic data), range of motion, and degree of pain. Radiologic results were evaluated based on the radiolucent line (RLL), degree of medial tibial bone loss, and loosening as seen on X-ray. RESULTS: No significant differences were observed in clinical scores or patient preference. Regarding implant weight, approximately 70% of patients did not perceive the Ti implant as lighter. No significant differences were observed in gait analysis, range of motion, or degree of pain. The RLL was seen in 9% of the Ti implant group and 19% of the CoCr implant group. CONCLUSION: The lighter Ti implant did not show any clinical benefit over CoCr implants. The lightness of the Ti implant is not sufficient to matter or be noticeable. However, the Ti implant showed lower rate of RLL than the CoCr implant. LEVEL OF EVIDENCE: level I, randomized controlled trial.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kim JK, Park IW, Ro DH, et al. Is a Titanium Implant for Total Knee Arthroplasty Better? A Randomized Controlled Study. J Arthroplasty. 2020. PMID: 33349499. doi:10.1016/j.arth.2020.11.010