MicroCT强度直方图脂肪浸润指标与肩袖修复力学强度的相关性:离体兔模型
该离体兔模型研究开发了一种半自动程序,基于microCT图像生成强度直方图以量化肌肉脂肪浸润。结果显示直方图均值与脂肪百分比负相关(-0.92),与最大载荷正相关(0.77);直方图标准差与脂肪百分比正相关(0.88),与最大载荷负相关(-0.72)。提示直方图指标可作为肩袖修复强度的替代指标。
要点
- 直方图均值与脂肪百分比负相关(r=-0.92,p<0.001),与最大载荷正相关(r=0.77,p=0.001)。
- 直方图标准差与脂肪百分比正相关(r=0.88,p<0.001),与最大载荷负相关(r=-0.72,p=0.004)。
核心结论
- 在离体兔模型中,基于microCT图像的半自动方法可无创量化脂肪浸润,并与肌腱愈合强度相关。
研究设计与样本
- 研究纳入12只成年雌性新西兰白兔(8-12月龄,体重3.7 kg ± 5 kg),随机分配至手术修复组或假手术修复组,对诱导的冈下肌缺损进行修复。
- 从手术侧和对侧完整肩关节获取microCT图像,由用户基于解剖特征选择感兴趣区生成强度直方图,计算均值和标准差。
- 将直方图指标与脂肪体积百分比及肱骨-冈下肌骨-肌腱-肌肉复合体的最大拉伸载荷进行相关性分析(Pearson相关系数)。
主要发现
- 脂肪百分比与直方图均值负相关(r=-0.92,p<0.001),与直方图标准差正相关(r=0.88,p<0.001)。
- 直方图均值与最大载荷正相关(r=0.77,p=0.001),直方图标准差与最大载荷负相关(r=-0.72,p=0.004)。
- 将最大载荷按动物体型归一化后,直方图均值与最大载荷的相关系数为0.86,直方图标准差与最大载荷的相关系数为-0.9。
关键数值与推荐
- 直方图均值与脂肪百分比负相关(Pearson相关系数-0.92;p<0.001)。
- 直方图标准差与脂肪百分比正相关(Pearson相关系数0.88;p<0.001)。
- 直方图均值与最大载荷正相关(Pearson相关系数0.77;p=0.001)。
- 直方图标准差与最大载荷负相关(Pearson相关系数-0.72;p=0.004)。
临床怎么用
- 直方图衍生变量可作为肩袖修复后修复强度的替代指标。
- 该半自动方法便于不同经验用户量化脂肪浸润,并可适配任何基于强度的成像方式。
- 需在MRI或常规CT上校准并应用于患者扫描,进一步评估其与临床力学结果的相关性。
局限性
- 本研究为离体兔模型,样本量12只,结果需在人体研究中验证。
- 该方法基于microCT,需校准后才能用于临床MRI或常规CT。
- 尚未评估直方图指标与临床力学结果的相关性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fatty infiltration of the rotator cuff occurs after injury to the tendon and results in a buildup of adipose in the muscle. Fatty infiltration may be a biomarker for predicting future injuries and mechanical properties after tendon repair. As such, quantifying fatty infiltration accurately could be a relevant metric for determining the success of tendon repairs. Currently, fatty infiltration is quantified by an experienced observer using the Goutallier or Fuchs staging system, but because such score-based quantification systems rely on subjective assessments, newer techniques using semiautomated analyses in CT and MRI were developed and have met with varying degrees of success. However, semiautomated analyses of CT and MRI results remain limited in cases where only a few two-dimensional slices of tissue are examined and applied to the three-dimensional (3-D) tissue structure. We propose that it is feasible to assess fatty infiltration within the 3-D volume of muscle and tendon in a semiautomated fashion by selecting anatomic features and examining descriptive metrics of intensity histograms collected from a cylinder placed within the central volume of the muscle and tendon of interest. QUESTIONS/PURPOSES: (1) Do descriptive metrics (mean and SD) of intensity histograms from microCT images correlate with the percentage of fat present in muscle after rotator cuff repair? (2) Do descriptive metrics of intensity histograms correlate with the maximum load during mechanical testing of rotator cuff repairs? METHODS: We developed a custom semiautomated program to generate intensity histograms based on user-selected anatomic features. MicroCT images were obtained from 12 adult female New Zealand White rabbits (age 8 to 12 months, weight 3.7 kg ± 5 kg) that were randomized to surgical repair or sham repair of an induced infraspinatus defect. Intensity histograms were generated from images of the operative and contralateral intact shoulder in these rabbits which were presented to the user in a random order without identifying information to minimize sources of bias. The mean and SD of the intensity histograms were calculated and compared with the total percentage of the volume threshold as fat. Patterns of fat identified were qualitatively compared with histologic samples to confirm that thresholding was detecting fat. We conducted monotonic tensile strength-to-failure tests of the humeral-infraspinatus bone-tendon-muscle complex, and evaluated associations between histogram mean and SDs and maximum load. RESULTS: The total percentage of fat was negatively correlated with the intensity histogram mean (Pearson correlation coefficient -0.92; p < 0.001) and positively with intensity histogram SD (Pearson correlation coefficient 0.88; p < 0.001), suggesting that the increase in fat leads to a reduction and wider variability in volumetric tissue density. The percentage of fat content was also negatively correlated with the maximum load during mechanical testing (Pearson correlation coefficient -78; p = 0.001), indicating that as the percentage of fat in the volume increases, the mechanical strength of the repair decreases. Furthermore, the intensity histogram mean was positively correlated with maximum load (Pearson correlation coefficient 0.77; p = 0.001) and histogram SD was negatively correlated with maximum load (Pearson correlation coefficient -0.72; p = 0.004). These correlations were strengthened by normalizing maximum load to account for animal size (Pearson correlation coefficient 0.86 and -0.9, respectively), indicating that as histogram mean decreases, the maximum load of the repair decreases and as histogram spread increases, the maximum load decreases. CONCLUSION: In this ex vivo rabbit model, a semiautomated approach to quantifying fat on microCT images was a noninvasive way of quantifying fatty infiltration associated with the strength of tendon healing. CLINICAL RELEVANCE: Histogram-derived variables may be useful as surrogate measures of repair strength after rotator cuff repair. The preclinical results presented here provide a foundation for future studies to translate this technique to patient studies and additional imaging modalities. This semiautomated method provides an accessible approach to quantification of fatty infiltration by users of varying experience and can be easily adapted to any intensity-based imaging approach. To translate this approach to clinical practice, this technique should be calibrated for MRI or conventional CT imaging and applied to patient scans. Further investigations are needed to assess the correlation of volumetric intensity histogram descriptive metrics to clinical mechanical outcomes.