文献速递运动医学

大鼠前交叉韧带重建中自体肌腱移植物生物力学与腱骨愈合优于混合移植物

An Autograft for Anterior Cruciate Ligament Reconstruction Results in Better Biomechanical Performance and Tendon-Bone Incorporation Than Does a Hybrid Graft in a Rat Model.
PubMed 文献 · Am J Sports Med · 2020-11-03

该研究在大鼠前交叉韧带重建模型中比较自体肌腱移植物与同种异体增强的混合移植物,发现自体组在术后8周和12周失败载荷与刚度更高,micro-CT显示胫骨侧新骨形成与骨重塑的BV/TV更高,组织学显示界面宽度更窄、Sharpey样纤维形成更早。结论提示自体移植物在生物力学性能和腱骨愈合方面优于混合移植物。

要点

  • 自体组术后8周和12周失败载荷与刚度均显著高于混合组。
  • 自体组胫骨侧骨隧道新骨形成和骨重塑的BV/TV在8周和12周更高。
  • 自体组移植物-骨界面宽度更窄,8周形成Sharpey样纤维。

核心结论

  • 大鼠模型中,前交叉韧带重建使用自体移植物在生物力学性能和腱骨愈合方面优于混合移植物。

研究设计与样本

  • 控制性实验室研究,66只成年雄性Sprague Dawley大鼠行单侧前交叉韧带重建,自体组33只、混合组33只,移植物取自腓骨长肌腱并以缝线固定于周围骨膜。

主要发现

  • 术后8周失败载荷自体组3.04±0.40 N、混合组2.09±0.54 N,P=.006;刚度自体组3.43±0.56 N/mm、混合组1.75±0.52 N/mm,P<.001。
  • 术后12周失败载荷自体组9.10±1.13 N、混合组7.14±0.94 N,P=.008;刚度自体组4.45±0.75 N/mm、混合组3.36±0.29 N/mm,P=.008。
  • 胫骨侧骨隧道新骨形成BV/TV:8周IA区自体组22.21±4.98、混合组5.16±3.98,P<.001;EA区自体组19.66±7.19、混合组10.85±2.16,P=.030;12周IA区自体组30.50±5.04、混合组17.11±7.31,P=.010;MT区自体组21.15±2.58、混合组15.55±4.48,P=.041;EA区自体组20.75±3.87、混合组10.64±3.94,P=.003。
  • 胫骨侧骨隧道周围骨重塑BV/TV:8周MT区自体组33.17±8.05、混合组15.21±7.60,P=.007;EA区自体组25.19±6.38、混合组13.94±7.10,P=.030;12周IA区自体组69.46±4.45、混合组47.80±6.16,P<.001;MT区自体组33.15±3.88、混合组13.76±4.07,P<.001。
  • 移植物-骨界面宽度自体组4周85.86±17.49 μm、混合组182.97±14.35 μm,P<.001;8周自体组58.86±10.99 μm、混合组90.15±11.53 μm,P=.002;12周自体组42.70±7.96 μm、混合组67.29±6.55 μm,P=.001。

临床怎么用

  • 临床行前交叉韧带重建时,应优先考虑自体肌腱移植物以获得更好的生物力学性能和腱骨愈合。
  • 用小自体移植物加同种异体组织增强可能降低生物力学性能并损害腱骨愈合,增加移植物失败风险。

局限性

  • 研究为大鼠动物模型,结论向人体临床转化需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The biomechanical and tendon-bone incorporation properties of allograft-augmented hybrid grafts for anterior cruciate ligament (ACL) reconstruction compared with traditional autografts are unknown. HYPOTHESIS: Using an autograft for ACL reconstruction yields better results on biomechanical testing, radiographic analysis, and histological evaluation versus using a hybrid graft. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 66 adult male Sprague Dawley rats underwent unilateral ACL reconstruction with an autograft (AT group; n = 33) or a hybrid graft (HB group; n = 33). The grafts used in both groups were harvested from the peroneus longus tendon and were fixed by suturing to the surrounding periosteum. Samples were harvested for biomechanical testing, micro-computed tomography (CT), and histological evaluation at 4, 8, and 12 weeks postoperatively. Bone tunnels on the femoral and tibial sides were divided into 3 subregions: intra-articular (IA), midtunnel (MT), and extra-articular (EA). A cylinder-like volume of interest in the bone tunnel and a tubular-like volume of interest around the bone tunnel were used to evaluate new bone formation and bone remodeling, respectively, via micro-CT. RESULTS: In the AT group, there were significantly higher failure loads and stiffness at 8 weeks (failure load: 3.04 ± 0.40 vs 2.09 ± 0.54 N, respectively; P = .006) (stiffness: 3.43 ± 0.56 vs 1.75 ± 0.52 N/mm, respectively; P < .001) and 12 weeks (failure load: 9.10 ± 1.13 vs 7.14 ± 0.94 N, respectively; P = .008) (stiffness: 4.45 ± 0.75 vs 3.36 ± 0.29 N/mm, respectively; P = .008) than in the HB group. With regard to new bone formation in the bone tunnel, in the AT group, the bone volume/total volume (BV/TV) was significantly higher than in the HB group on the tibial side at 8 weeks (IA: 22.21 ± 4.98 vs 5.16 ± 3.98, respectively; P < .001) (EA: 19.66 ± 7.19 vs 10.85 ± 2.16, respectively; P = .030) and 12 weeks (IA: 30.50 ± 5.04 vs 17.11 ± 7.31, respectively; P = .010) (MT: 21.15 ± 2.58 vs 15.55 ± 4.48, respectively; P = .041) (EA: 20.75 ± 3.87 vs 10.64 ± 3.94, respectively; P = .003). With regard to bone remodeling around the tunnel, the BV/TV was also significantly higher on the tibial side at 8 weeks (MT: 33.17 ± 8.05 vs 15.21 ± 7.60, respectively; P = .007) (EA: 25.19 ± 6.38 vs 13.94 ± 7.10, respectively; P = .030) and 12 weeks (IA: 69.46 ± 4.45 vs 47.80 ± 6.16, respectively; P < .001) (MT: 33.15 ± 3.88 vs 13.76 ± 4.07, respectively; P < .001) in the AT group than in the HB group. Sharpey-like fibers had formed at 8 weeks in the AT group. A large number of fibroblasts withdrew at 12 weeks. In the AT group, the width of the interface was significantly narrower at 4 weeks (85.86 ± 17.49 vs 182.97 ± 14.35 μm, respectively; P < .001), 8 weeks (58.86 ± 10.99 vs 90.15 ± 11.53 μm, respectively; P = .002), and 12 weeks (42.70 ± 7.96 vs 67.29 ± 6.55 μm, respectively; P = .001) than in the HB group. CONCLUSION: Using an autograft for ACL reconstruction may result in improved biomechanical properties and tendon-bone incorporation compared with a hybrid graft. CLINICAL RELEVANCE: Augmenting small autografts with allograft tissue may result in decreased biomechanical performance and worse tendon-bone incorporation, increasing the risk of graft failure.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Wang HD, Wang TR, Sui Y, et al. An Autograft for Anterior Cruciate Ligament Reconstruction Results in Better Biomechanical Performance and Tendon-Bone Incorporation Than Does a Hybrid Graft in a Rat Model. Am J Sports Med. 2020. PMID: 33141598. doi:10.1177/0363546520967668

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。