文献速递关节外科运动医学

无柄与有柄肱骨假体在解剖型全肩关节置换术中的前瞻性盲法随机对照试验:短期随访结果

Prospective, Blinded, Randomized Controlled Trial of Stemless Versus Stemmed Humeral Components in Anatomic Total Shoulder Arthroplasty: Results at Short-Term Follow-up.
PubMed 文献 · J Bone Joint Surg Am · 2020-01-01

2年随访时无柄组在ASES评分、无器械相关并发症比例及影像学松动方面均不劣于有柄组,活动度及ASES、SANE、Constant评分各时间点无显著差异。

要点

  • 2年随访无柄假体在ASES评分、器械相关并发症及影像学松动方面不劣于有柄假体。
  • 无柄组2年平均ASES评分92.5±14.9,有柄组92.2±13.5,非劣效检验P<0.0001。
  • 2年内两组活动度及ASES、SANE、Constant评分各时间点无显著差异。

核心结论

  • 2年随访时,无柄肱骨假体的安全性和有效性不劣于有柄肱骨假体,适用于因骨关节炎接受aTSA的患者。
  • 短期结果令人鼓舞,考虑到无柄设计相对传统有柄肱骨假体的潜在优势。

研究设计与样本

  • 前瞻性、多中心、单盲随机对照试验,比较无柄与短柄肱骨假体在aTSA患者中的应用。
  • 非劣效性统计分析在2年随访时针对3个主要终点进行:ASES评分、无器械相关并发症、影像学松动征象。

主要发现

  • 2年时平均ASES评分无柄组92.5±14.9,有柄组92.2±13.5,非劣效检验P<0.0001。
  • 2年时无器械相关并发症比例无柄组92%(107/116),有柄组93%(114/123),非劣效检验P=0.0063。
  • 两组均无肩出现影像学松动征象。
  • 2年随访内各时间点两组活动度及ASES、SANE、Constant评分无显著差异。

关键数值与推荐

  • 非劣效性主要终点为2年随访时的ASES评分、无器械相关并发症及影像学松动征象。
  • 2年时无柄组ASES评分92.5±14.9、有柄组92.2±13.5,非劣效检验P<0.0001。
  • 2年时无器械相关并发症比例无柄组92%(107/116)、有柄组93%(114/123),非劣效检验P=0.0063。
  • 两组均无影像学松动征象。

临床怎么用

  • 对于因骨关节炎接受aTSA的患者,无柄肱骨假体在2年短期随访中可作为有柄假体的非劣效选择。
  • 短期结果支持无柄设计的潜在优势,但需结合长期随访及影像学松动证据综合判断。

局限性

  • 随访时间仅为短期(2年),缺乏长期疗效与影像学松动数据。
  • 原文未报告具体非劣效界值、并发症类型分布及失访情况。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stemless humeral components for anatomic total shoulder arthroplasty (aTSA) have several reported potential benefits compared with stemmed implants. However, we are aware of no Level-I, randomized controlled trials (RCTs) that have compared stemless implants with stemmed implants in patients managed with aTSA. We sought to directly compare the short-term clinical and radiographic outcomes of stemless and stemmed implants to determine if the stemless implant is noninferior to the stemmed implant. METHODS: We performed a prospective, multicenter, single-blinded RCT comparing stemless and short-stemmed implants in patients managed with aTSA. Range-of-motion measurements and American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation (SANE), and Constant scores were obtained at multiple time points. Device-related complications were recorded. Radiographic evaluation for evidence of loosening, fractures, dislocation, or other component complications was performed. Statistical analysis for noninferiority was performed at 2 years of follow-up for 3 primary end points: ASES score, absence of device-related complications, and radiographic signs of loosening. All other data were compared between cohorts at all time points as secondary measures. RESULTS: Two hundred and sixty-five shoulders (including 176 shoulders in male patients and 89 shoulders in female patients) were randomized and received the allocated treatment. The mean age of the patients (and standard deviation) was 62.6 ± 9.3 years, and 99% of the shoulders had a primary diagnosis of osteoarthritis. At 2 years, the mean ASES score was 92.5 ± 14.9 for the stemless cohort and 92.2 ± 13.5 for the stemmed cohort (p value for noninferiority test, <0.0001), the proportion of shoulders without device-related complications was 92% (107 of 116) for the stemless cohort and 93% (114 of 123) for the stemmed cohort (p value for noninferiority test, 0.0063), and no shoulder in either cohort had radiographic signs of loosening. Range-of-motion measurements and ASES, SANE, and Constant scores did not differ significantly between cohorts at any time point within the 2-year follow-up. CONCLUSIONS: At 2 years of follow-up, the safety and effectiveness of the stemless humeral implant were noninferior to those of the stemmed humeral implant in patients managed with aTSA for the treatment of osteoarthritis. These short-term results are promising given the potential benefits of stemless designs over traditional, stemmed humeral components. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Wiater JM, Levy JC, Wright SA, et al. Prospective, Blinded, Randomized Controlled Trial of Stemless Versus Stemmed Humeral Components in Anatomic Total Shoulder Arthroplasty: Results at Short-Term Follow-up. J Bone Joint Surg Am. 2020. PMID: 33208640. doi:10.2106/JBJS.19.01478

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。