全髋关节置换术前模板规划准确性:关注股骨柄形态的随机对照研究

Accuracy of Preoperative Templating in Total Hip Arthroplasty With Special Focus on Stem Morphology: A Randomized Comparison Between Common Digital and Three-Dimensional Planning Using Biplanar Radiographs.
PubMed 文献 · J Arthroplasty · 2020-10-17

该随机对照研究纳入51例全髋关节置换患者,比较三维hipEOS与二维TraumaCad模板规划的准确性和可靠性。结果显示两种方法观察者内可靠性均良好,但三维规划观察者间ICC更高,且对短柄假体的规划准确性显著优于二维规划,直柄和髋臼杯则无显著差异。

要点

  • 三维hipEOS规划对短柄假体的准确性显著优于二维TraumaCad规划(P=.029)。
  • 两种方法对直柄(P=.935)和髋臼杯(P=.954)的规划准确性无显著差异。
  • 三维规划观察者间ICC(0.906-0.918)高于二维规划(0.835-0.843)。

核心结论

  • 三维hipEOS模板规划总体可靠性良好,对短柄假体的规划准确性可能优于二维TraumaCad规划。

研究设计与样本

  • 随机对照研究,51例全髋关节置换患者随机分为两组,23例接受hipEOS三维规划,28例接受TraumaCad二维规划。

主要发现

  • 两种方法观察者内可靠性均良好(ICC2,1:0.835-0.967)。
  • 股骨柄和髋臼杯规划的观察者间ICC2,1三维规划为0.906-0.918,二维规划为0.835-0.843。
  • 三维规划股骨柄和髋臼杯总尺寸预测在2个尺寸以内,二维规划在3个尺寸以内。
  • 短柄假体规划中,植入与规划尺寸的绝对差值三维规划显著更低(P=.029)。
  • 直柄假体(P=.935)和髋臼杯(P=.954)规划准确性无显著差异。

关键数值与推荐

  • 短柄假体规划准确性:三维规划显著优于二维规划(P=.029)。
  • 直柄假体规划准确性:两种方法无显著差异(P=.935)。
  • 髋臼杯规划准确性:两种方法无显著差异(P=.954)。

临床怎么用

  • 对于计划使用短柄假体的全髋关节置换,可优先考虑三维hipEOS模板规划以提高尺寸预测准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Accurate preoperative planning is a key component of successful total hip arthroplasty (THA). The purpose of the present study was to compare the accuracy and reliability of three-dimensional (hipEOS) and common digital two-dimensional (TraumaCad) templating with special focus on stem morphology. METHODS: 51 patients undergoing THA were randomized to two groups. Preoperative planning was performed on 23 patients with hipEOS (3D) and on 28 patients with TraumaCad (2D) planning software. Planning results were compared with the implanted component size. Inter- and intraobserver reliability as well as planning accuracy of both planning methods with special focus on straight and short stem design were recorded. RESULTS: Intraobserver reliability of both planning methods was good for component planning (ICC2,1: 0.835-0.967). Interobserver ICC2,1 for stem and cup planning were higher for 3D templating (3D ICC2,1: 0.906-0.918 vs. 2D ICC2,1: 0.835-0.843). Total stem and cup size predictions were within 2 sizes for 3D and within 3 sizes for 2D planning. Comparing short stem planning accuracy of both planning methods, absolute difference between implanted and planned component size was significantly lower in 3D planning (P = .029). There was no significant difference in straight stem (P = .935) and cup (P = .954) planning accuracy. CONCLUSION: Our findings suggest that 3D templating with hipEOS software has a good overall reliability and may have a better planning accuracy of short stem prostheses than digital templating with TraumaCad software. Assuming that the number of implanted short stem prostheses will further increase in coming years, a more precise planning with 3D technique can contribute to improve surgery outcome.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Brenneis M, Braun S, van Drongelen S, et al. Accuracy of Preoperative Templating in Total Hip Arthroplasty With Special Focus on Stem Morphology: A Randomized Comparison Between Common Digital and Three-Dimensional Planning Using Biplanar Radiographs. J Arthroplasty. 2020. PMID: 33160804. doi:10.1016/j.arth.2020.10.016