文献速递关节外科

加速度计便携导航系统在全膝关节置换术中的有效性:多中心前瞻性随机对照试验

Usefulness of an Accelerometer-Based Portable Navigation System for Total Knee Arthroplasty: A Multicenter Prospective Randomized Controlled Trial.
PubMed 文献 · J Bone Joint Surg Am · 2020-01-01

术后6个月负重位X线片测量显示,导航组股骨假体、胫骨假体及髋-膝-踝角与中立机械轴的绝对偏差均小于常规组,且胫骨假体和髋-膝-踝角的对线不良(偏离中立机械轴>2°)比例更低,手术时间无显著差异,无导航相关并发症。

要点

  • 导航组股骨假体、胫骨假体及髋-膝-踝角与中立机械轴的绝对偏差均显著小于常规组。
  • 导航组胫骨假体对线不良(>2°)比例为9%,常规组为31%(p=0.01)。
  • 导航组髋-膝-踝角对线不良(>2°)比例为27%,常规组为49%(p=0.04)。

核心结论

  • 加速度计便携导航系统在冠状面提供比常规技术更准确的假体与肢体对线,且不延长手术时间、不增加并发症率。

研究设计与样本

  • 术后6个月由对分组不知情的经验丰富外科医生使用计算机软件测量负重位全下肢X线片对线,精确到1位小数。
  • 功效分析显示每组需41膝。

主要发现

  • 术后X线片每组各获得45例患者资料;两组在性别、年龄、身高、体重、体重指数、术前股胫角及手术时间方面无显著差异。
  • 导航组股骨假体(p=0.01)、胫骨假体(p<0.01)及髋-膝-踝角(p<0.01)与中立机械轴的绝对偏差均小于常规组。
  • 导航组胫骨假体对线不良(偏离中立机械轴>2°)比例为9%,常规组为31%(p=0.01)。
  • 导航组髋-膝-踝角对线不良(偏离中立机械轴>2°)比例为27%,常规组为49%(p=0.04)。
  • 无因使用加速度计便携导航系统导致的并发症。

关键数值与推荐

  • 对线不良定义为偏离中立机械轴>2°。
  • 导航组胫骨假体对线不良9%,常规组31%(p=0.01)。
  • 导航组髋-膝-踝角对线不良27%,常规组49%(p=0.04)。

临床怎么用

  • 对于原发性内翻性膝骨关节炎行全膝关节置换术,加速度计便携导航系统可在不延长手术时间、不增加并发症的情况下改善冠状面对线精度。
  • 研究结果可帮助骨科医生决定是否使用加速度计便携导航系统。

局限性

  • 术后X线片每组仅获得45例患者资料(初始每组50例)。
  • 对线测量精确到1位小数,由单一经验丰富外科医生完成。
  • 随访时间为术后6个月。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: An accelerometer-based portable navigation system was recently introduced to improve prosthetic alignment during total knee arthroplasty (TKA). The purpose of this multicenter prospective randomized controlled trial (RCT) was to evaluate the effects of this accelerometer-based portable navigation system for achieving more accurate alignment during TKA in the clinical setting. METHODS: One hundred patients with primary varus osteoarthritis of the knee were enrolled in this prospective RCT conducted in 5 hospitals. A navigation system was utilized in 50 patients (navigation group), and a conventional intramedullary femoral guide and an extramedullary tibial guide were utilized in 50 patients (conventional group). At 6 months postoperatively, weight-bearing radiographs were obtained of the whole operative leg. An experienced surgeon who was blinded to the treatment assignments then measured the alignment to 1 decimal place with use of computer software. Power analysis showed that 41 knees were required in each group. RESULTS: There were no complications as a result of the use of the accelerometer-based portable navigation system. Postoperative radiographs were obtained in 45 patients from each group. There were no significant differences in sex, age, height, body weight, body mass index, preoperative femorotibial angle, and operative time between groups. The absolute differences of the femoral prosthesis (p = 0.01), tibial prosthesis (p < 0.01), and hip-knee-ankle angle (p < 0.01) from a neutral mechanical axis were less in the navigation group compared with those in the conventional group. Alignment outliers (>2° away from the neutral mechanical axis) of the tibial prosthesis and hip-knee-ankle angle were less in the navigation group (9% and 27%, respectively) compared with those in the conventional group (31% and 49%; p = 0.01 and p = 0.04, respectively). CONCLUSIONS: To our knowledge, this is the first multicenter prospective RCT to evaluate an accelerometer-based portable navigation system. An accelerometer-based portable navigation system provides more accurate prosthetic and limb alignment in the coronal plane than conventional techniques, without extended operative time or an increased rate of complications. The results of this study may help orthopaedic surgeons decide whether or not to use an accelerometer-based portable navigation system. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Minoda Y, Hayakawa K, Hagio K, et al. Usefulness of an Accelerometer-Based Portable Navigation System for Total Knee Arthroplasty: A Multicenter Prospective Randomized Controlled Trial. J Bone Joint Surg Am. 2020. PMID: 33208642. doi:10.2106/JBJS.20.00387

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。