文献速递运动医学关节外科

保留残端后交叉韧带重建术后残端后交叉韧带与跟腱同种异体移植物中的机械感受器:苏木精-伊红与免疫组化评估

Mechanoreceptors in Remnant Posterior Cruciate Ligament and Achilles Tendon Allografts After Remnant-Preserving Posterior Cruciate Ligament Reconstruction: Hematoxylin-Eosin and Immunohistochemical Assessments.
PubMed 文献 · Am J Sports Med · 2020-09-10

该对照实验室研究对14例接受跟腱同种异体移植后交叉韧带重建(PCLR)的患者(其中12例采用保留残端技术)及4例健康对照取材,用免疫组化检测机械感受器。结果显示跟腱同种异体移植物中均未发现机械感受器,而保留残端的后交叉韧带组织中12例有11例(91.7%)存在机械感受器。

要点

  • 跟腱同种异体移植物中未发现机械感受器。
  • 保留残端的后交叉韧带组织中12例有11例(91.7%)存在机械感受器。
  • 作者认为该组织学证据支持保留残端技术保留本体感觉的优势。

核心结论

  • 跟腱同种异体移植物缺乏机械感受器。
  • 该研究可作为组织学证据支持保留残端技术用于PCLR的优势,因其保留本体感觉。

研究设计与样本

  • 对照实验室研究,PCLR组14例接受跟腱同种异体移植的PCLR患者(其中12例采用保留残端技术,2例采用非保留残端技术),对照组4例健康对照。
  • PCLR组样本取自PCLR术后二次关节镜或全膝关节置换术,对照组取自接受其他关节镜手术患者的正常PCL组织活检标本。
  • 对所有活检标本行免疫组化检测神经与神经细胞标志物(胶质纤维酸性蛋白、神经元特异性烯醇化酶、神经丝蛋白、S-100蛋白),任一标志物阳性即证明存在机械感受器。

主要发现

  • 对照组所有标本均发现神经组织类似物,经单克隆抗体证实为机械感受器。
  • 跟腱同种异体移植物标本中未发现机械感受器。
  • 保留残端的PCL组织中12例有11例(91.7%)发现机械感受器。

临床怎么用

  • 作者认为,为保留本体感觉从而获得更好的功能结果,使用残端技术是PCL重建的更好术式。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Mechanoreceptor is a subtype of somatosensory receptor. It conveys extracellular stimuli through intracellular signal conduction via mechanically gated ion channel. It conveys not only kinetic stimuli but also pressure, stretching, touch, and even sound wave. Few studies have determined whether mechanoreceptors are present in Achilles tendon allografts used during remnant-preserving posterior cruciate ligament (PCL) reconstruction (PCLR). PURPOSE/HYPOTHESIS: The purpose was to investigate whether mechanoreceptors are present in remnant tissues of the PCL and allograft tissues after PCLR. It was hypothesized that mechanoreceptors may be present in the remnant PCL tissue of the patients who underwent remnant PCLR technique. STUDY DESIGN: Controlled laboratory study. METHODS: Tissue samples were obtained from 14 participants who had undergone PCLR by means of Achilles tendon allografts (PCLR group) and from 4 healthy controls (control group). Among the PCLR group, 12 patients had undergone a remnant PCLR technique and the remaining 2 patients had undergone a nonremnant PCLR technique. In the PCLR group, we obtained samples during second-look arthroscopy or total knee arthroplasty after PCLR. In the control group, 4 biopsy specimens of normal PCL tissues were obtained from patients who had undergone other arthroscopic procedures. To check the presence of mechanoreceptors, immunohistochemical studies were performed on all biopsy specimens to identify neuronal and neurocytic markers by using monoclonal antibodies against glial fibrillary acidic protein, neuron-specific enolase, neurofilament, and S-100 protein. Only 1 of these markers needed to be positive to prove the presence of mechanoreceptors. RESULTS: Neural tissue analogs, confirmed to be mechanoreceptors with monoclonal antibodies by the Ultraview DAB detection kit, were found in all specimens obtained from the control group. Mechanoreceptors were not found in the allograft specimens. However, remnant PCL tissues were found to have mechanoreceptors in 11 of 12 samples (91.7%). CONCLUSION: The results demonstrate that Achilles tendon allografts lack mechanoreceptors. This study can be used as histological evidence to support the advantage of remnant-preserving techniques for PCLR because they preserve proprioception. CLINICAL RELEVANCE: To preserve proprioception, which leads to better functional outcome, using the remnant technique is a better procedure for PCL reconstruction.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Chun KC, Shin CH, Kang HT, et al. Mechanoreceptors in Remnant Posterior Cruciate Ligament and Achilles Tendon Allografts After Remnant-Preserving Posterior Cruciate Ligament Reconstruction: Hematoxylin-Eosin and Immunohistochemical Assessments. Am J Sports Med. 2020. PMID: 32997531. doi:10.1177/0363546520950764

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。