全膝关节置换术中股骨远端额外截骨4毫米并未使伸直位关节间隙等量增加
本研究对50例因内翻性骨关节炎行全膝关节置换术的膝关节,比较标准股骨假体模型与模拟股骨远端额外截骨4毫米的假体模型在伸直位关节间隙上的差异。结果显示额外截骨模型关节间隙大于标准模型(P<.01),但平均仅增加2毫米(标准差1毫米),小于额外截骨的4毫米厚度(P<.01)。结论认为股骨远端额外截骨量不等于伸直位关节间隙增加量。
要点
- 股骨远端额外截骨4毫米后,伸直位关节间隙平均仅增加2毫米。
- 额外截骨模型关节间隙大于标准模型(P<.01)。
- 关节间隙增加量小于额外截骨厚度(P<.01)。
核心结论
- 股骨远端额外截骨量不等于伸直位关节间隙增加量,额外截骨4毫米仅使伸直位关节间隙平均增加2毫米。
研究设计与样本
- 对50例因内翻性骨关节炎行全膝关节置换术的膝关节进行评价,比较标准模型与模拟股骨远端额外截骨4毫米的假体模型。
- 标准模型股骨远端和后方假体厚度均为9毫米,额外截骨模型股骨远端假体厚度为5毫米(由9毫米变为4毫米)、后方假体厚度为9毫米。
- 在假体植入前放置股骨试模,使用与固定平台胫骨垫片形状相同的张力装置测量伸直位关节间隙。
主要发现
- 额外截骨模型关节间隙大于标准模型(P<.01)。
- 额外截骨模型伸直位关节间隙平均增加2毫米(标准差1毫米),小于额外截骨厚度4毫米(P<.01)。
关键数值与推荐
- 额外截骨模型伸直位关节间隙平均增加2毫米(标准差1毫米),小于额外截骨厚度4毫米(P<.01)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Additional bone resection in the distal femur is performed to increase the extension joint gap in total knee arthroplasty (TKA). The present study aimed to analyze the relationship between the amount of additional bone resection in the distal femur and the increase in the extension joint gap in TKA. METHODS: Fifty knees undergoing TKA for varus osteoarthritis were evaluated. Two femoral trial component models were prepared: (1) a normal model with 9-mm-thick distal and posterior femoral components and (2) an additional bone resection model with a 5-mm-thick distal femoral component (9 mm to 4 mm) and a 9-mm-thick posterior femoral component, which simulated an additional bone cut in the distal femur of 4 mm. The femoral trial component models were set before implantation, and the extension joint gap was measured using a tensor device that had a shape identical to that of the fixed-bearing tibial insert. RESULTS: The additional bone resection model had a larger joint gap than the normal model (P < .01). The mean extension gap increase in the additional bone resection model was 2 (standard deviation 1) mm, which was less than the thickness of the additional bone resection (4 mm) (P < .01). CONCLUSION: The amount of additional bone resection in the distal femur was not equal to the increase in the extension joint gap. Additional bone resection of 4 mm in the distal femur only increased the extension joint gap by a mean of 2 mm.
引用
- Minoda Y, Sugama R, Ohta Y, et al. Four-Millimeter Additional Bone Resection in the Distal Femur Does Not Result in an Equivalent Increase in the Extension Joint Gap in Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32994112. doi:10.1016/j.arth.2020.09.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。