文献速递关节外科创伤骨科

内侧化肩胛盂与外侧化肱骨假体反式全肩关节置换术后肩峰与肩胛骨骨折:结局与危险因素分析

Acromial and Scapular Fractures After Reverse Total Shoulder Arthroplasty with a Medialized Glenoid and Lateralized Humeral Implant: An Analysis of Outcomes and Risk Factors.
PubMed 文献 · J Bone Joint Surg Am · 2020-01-01

本研究分析4125例(3995例患者)初次反式全肩关节置换术(rTSA)后肩峰与肩胛骨骨折的发生率、危险因素及结局,骨折率为1.77%,平均术后17.7±21.1个月发生。多因素分析显示女性、类风湿关节炎、肩袖撕裂关节病及更多基底板螺钉是危险因素,骨折患者临床结局显著更差。

要点

  • rTSA后肩峰与肩胛骨骨折率为1.77%,平均术后17.7±21.1个月发生。
  • 女性、类风湿关节炎、肩袖撕裂关节病及更多基底板螺钉与骨折风险升高相关。
  • 骨折患者临床结局显著更差,平均改善差异超过大多数指标的MCID。

核心结论

  • rTSA后肩峰与肩胛骨骨折不常见,骨折患者临床结局显著更差。
  • 多因素logistic回归分析识别出女性、类风湿关节炎、肩袖撕裂关节病及使用更多基底板螺钉为危险因素。
  • 考虑这些发现和患者特异性危险因素可能有助于骨科医生术前更好地告知患者这一罕见并发症,并在术后评估时更警惕该并发症。

研究设计与样本

  • 回顾性分析4125个肩关节(3995例患者),由23名骨科医生采用单一设计反式肩关节假体行初次rTSA。
  • 61个肩关节经影像学识别肩峰与肩胛骨骨折,比较骨折与非骨折患者的人口学特征、合并症、假体相关数据及临床结局。
  • 采用多因素logistic回归、双尾非配对t检验、卡方检验或Fisher精确检验确定显著差异(p<0.05)。
  • 证据等级:预后Level III。

主要发现

  • 最低随访2年时,肩峰与肩胛骨骨折率为1.77%,骨折平均发生时间为术后17.7±21.1个月。
  • Levy分型:Type-1骨折10例,Type-2骨折32例,Type-3骨折18例,1例无法分型。
  • 骨折患者较无骨折患者更可能为女性(84.0% vs 64.5%,p=0.004;OR=2.75,95%CI 1.45至5.78)。
  • 骨折患者合并类风湿关节炎比例更高(9.8% vs 3.3%,p=0.010;OR=3.14,95%CI 1.18至6.95)。
  • 骨折患者合并肩袖撕裂关节病比例更高(54.1% vs 37.8%,p=0.005;OR=2.07,95%CI 1.24至3.47)。

关键数值与推荐

  • 骨折率1.77%(61/4125肩关节),平均发生时间17.7±21.1个月。
  • 女性OR=2.75(95%CI 1.45至5.78),类风湿关节炎OR=3.14(95%CI 1.18至6.95),肩袖撕裂关节病OR=2.07(95%CI 1.24至3.47),基底板螺钉数量OR=1.53(95%CI 1.08至2.17)。
  • Levy分型分布:Type-1 10例,Type-2 32例,Type-3 18例,无法分型1例。

临床怎么用

  • 考虑这些发现和患者特异性危险因素可能有助于骨科医生术前更好地告知患者这一罕见并发症,并在术后评估时更警惕该并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: This article was updated on TK because of a previous error, which was discovered after the preliminary version of the article was posted online. In Table VII, the fracture rate in the study by Walch et al. that had read "4.6% (21 of 457)" now reads "0.9% (4 of 457)." BACKGROUND: Acromial and scapular fractures after reverse total shoulder arthroplasty (rTSA) are rare and challenging complications, and little information is available in the literature to identify patients who are at risk. This study analyzes risk factors for, and compares the outcomes of patients with and without, acromial and scapular fractures after rTSA with a medialized glenoid/lateralized humeral implant. METHODS: Four thousand one hundred and twenty-five shoulders in 3,995 patients were treated with primary rTSA with 1 design of reverse shoulder prosthesis by 23 orthopaedic surgeons. Sixty-one of the 4,125 shoulders had radiographically identified acromial and scapular fractures. Demographic characteristics, comorbidities, implant-related data, and clinical outcomes were compared between patients with and without fractures to identify risk factors. A multivariate logistic regression, 2-tailed unpaired t test, and chi-square test or Fisher exact test identified significant differences (p < 0.05). RESULTS: After a minimum duration of follow-up of 2 years, the rate of acromial and scapular fractures was 1.77%, with the fractures occurring at a mean (and standard deviation) of 17.7 ± 21.1 months after surgery. Ten patients had a Levy Type-1 fracture, 32 had a Type-2 fracture, 18 had a Type-3 fracture, and 1 fracture could not be classified. Patients with acromial and scapular fractures were more likely to be female (84.0% versus 64.5% [p = 0.004]; odds ratio [OR] = 2.75 [95% confidence interval (CI) = 1.45 to 5.78]), to have rheumatoid arthritis (9.8% versus 3.3% [p = 0.010]; OR = 3.14 [95% CI = 1.18 to 6.95]), to have rotator cuff tear arthropathy (54.1% versus 37.8% [p = 0.005]; OR = 2.07 [95% CI = 1.24 to 3.47]), and to have more baseplate screws (4.1 versus 3.8 screws [p = 0.017]; OR = 1.53 [95% CI = 1.08 to 2.17]) than those without fractures. No other implant-related differences were observed in the multivariate analysis. Patients with fractures had significantly worse outcomes than patients without fractures, and the difference in mean improvement between these 2 cohorts exceeded the minimum clinically important difference for the majority of measures. CONCLUSIONS: Acromial and scapular fractures after rTSA are uncommon, and patients with these fractures have significantly worse clinical outcomes. Risk factors, including female sex, rheumatoid arthritis, cuff tear arthropathy, and usage of more baseplate screws were identified on multivariate logistic regression analysis. Consideration of these findings and patient-specific risk factors may help the orthopaedic surgeon (1) to better inform patients about this rare complication preoperatively and (2) to be more vigilant for this complication when evaluating patients postoperatively. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Routman HD, Simovitch RW, Wright TW, et al. Acromial and Scapular Fractures After Reverse Total Shoulder Arthroplasty with a Medialized Glenoid and Lateralized Humeral Implant: An Analysis of Outcomes and Risk Factors. J Bone Joint Surg Am. 2020. PMID: 33027125. doi:10.2106/JBJS.19.00724

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。