文献速递关节外科运动医学

调整假体尺寸与位置可在三维计算模型中改善反式全肩关节置换术后的内旋

Adjusting Implant Size and Position Can Improve Internal Rotation After Reverse Total Shoulder Arthroplasty in a Three-dimensional Computational Model.
PubMed 文献 · Clin Orthop Relat Res · 2021-01-01

该CT建模研究对25例Walch A1肩胛盂患者进行反式全肩关节置换术三维模板规划,改变基座外侧化、盂球尺寸、盂球悬突、肱骨版本和肱骨颈干角等参数,发现联合改变可显著提高无撞击内旋范围(中位数从基线85°提升至119°,中位差值37°,p<0.001),而单独盂侧外侧化无效。

要点

  • 联合改变基座外侧化、下移、内翻颈干角、增大盂球尺寸和增加肱骨前倾,内旋改善最大(中位差值37°)。
  • 单独盂侧外侧化未能改善内旋,而盂球悬突增加、内翻颈干角和肱骨前倾可改善内旋。
  • 模拟中内旋改善的配置未伴随外旋和伸展范围的损失。

核心结论

  • 在计算模型中,增加盂球悬突、内翻颈干角和肱骨前倾可改善内旋,而单独盂侧外侧化不能;联合这些技术对内旋改善最大。

研究设计与样本

  • CT建模研究,采用去标识教学数据库中25例连续Walch A1肩胛盂患者的CT图像进行反式全肩关节置换术三维模板规划,使用同一假体配置(覆盖式肱骨设计、36毫米标准盂球),模拟活动度至骨性撞击,逐一改变基座外侧化、盂球尺寸、盂球悬突、肱骨版本和肱骨颈干角等参数并组合。

主要发现

  • 联合外侧化、下移、内翻颈干角、增大盂球尺寸和增加肱骨前倾,内旋改善大于任何单一参数改变(基线内旋中位数85°[四分位距73°至90°];联合改变后119°[IQR 113°至121°],中位差值37°[IQR 32°至43°];p < 0.001)。
  • 单独盂侧外侧化未改善内旋。
  • 模拟中内旋改善的配置未伴随外旋和伸展范围的损失。

关键数值与推荐

  • 联合改变后无撞击内旋中位数119°(IQR 113°至121°),较基线85°(IQR 73°至90°)中位差值37°(IQR 32°至43°),p < 0.001。

临床怎么用

  • 作者认为,外科医生在规划和执行反式全肩关节置换术时可使用目前可用的假体配置(包括下移、内翻颈干角、增大盂球尺寸和增加肱骨前倾)来改善内旋。
  • 作者指出,这些发现支持需要进一步的临床研究验证假体配置对内旋的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Efforts during reverse total shoulder arthroplasty (RSA) have typically focused on maximizing ROM in elevation and external rotation and avoiding scapular notching. Improving internal rotation (IR) is often overlooked, despite its importance for functional outcomes in terms of patient self-care and hygiene. Although determinants of IR are multifactorial, it is unable to surpass limits of bony impingement of the implant. Identifying implant configurations that can reduce bony impingement in a computer model will help surgeons during preoperative planning and also direct implant design and clinical research going forward. QUESTIONS/PURPOSES: In a CT-modeling study, we asked: What reverse total shoulder arthroplasty implant position improves the range of impingement free internal rotation without compromising other motions (external rotation and extension)? METHODS: CT images stored in a deidentified teaching database from 25 consecutive patients with Walch A1 glenoids underwent three-dimensional templating for RSA. Each template used the same implant and configuration, which consisted of an onlay humeral design and a 36-mm standard glenosphere. The resulting constructs were virtually taken through ROM until bony impingement was found. Variations were made in the RSA parameters of baseplate lateralization, glenosphere size, glenosphere overhang, humeral version, and humeral neck-shaft angle. Simulated ROM was repeated after each parameter was changed individually and then again after combining multiple changes into a single configuration. The impingement-free IR was calculated and compared between groups. We also evaluated the effect on other ROM including external rotation and extension to ensure that configurations with improvements in IR were not associated with losses in other areas. RESULTS: Combining lateralization, inferiorization, varus neck-shaft angle, increased glenosphere size, and increased humeral anteversion resulted in a greater improvement in internal rotation than any single parameter change did (median baseline IR: 85° [interquartile range 73° to 90°]; combined changes: 119° [IQR 113° to 121°], median difference: 37° [IQR 32° to 43°]; p < 0.001). CONCLUSION: Increased glenosphere overhang, varus neck-shaft angle, and humeral anteversion improved internal rotation in a computational model, while glenoid lateralization alone did not. Combining these techniques led to the greatest improvement in IR. CLINICAL RELEVANCE: This computer model study showed that various implant changes including inferiorization, varus neck-shaft angle, increased glenosphere size, and increased humeral anteversion can be combined to increase impingement-free IR. Surgeons can employ these currently available implant configurations to improve IR when planning and performing RSA. These findings support the need for further clinical studies validating the effect of implant configuration on resultant IR.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Huish EG, Athwal GS, Neyton L, et al. Adjusting Implant Size and Position Can Improve Internal Rotation After Reverse Total Shoulder Arthroplasty in a Three-dimensional Computational Model. Clin Orthop Relat Res. 2021. PMID: 33044311. doi:10.1097/CORR.0000000000001526

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。