文献速递关节外科

维生素E掺杂全髋关节置换内衬五年股骨头穿透与高交联聚乙烯相似:多臂随机对照试验

Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial.
PubMed 文献 · Bone Joint J · 2020-01-01

该多臂随机对照试验将行全髋关节置换术的患者随机分配至维生素E掺杂聚乙烯内衬或标准高交联聚乙烯内衬,并采用32 mm或36 mm金属股骨头(2×2析因设计)。五年时两种内衬材料间及两种股骨头尺寸间股骨头穿透均无显著差异,髋臼假体迁移和患者报告结局亦无差异。

要点

  • 五年时维生素E掺杂内衬与高交联聚乙烯内衬的股骨头穿透差异为-0.084 mm(95%CI -0.173至0.005;p=0.064),无显著差异。
  • 五年时32 mm与36 mm股骨头的股骨头穿透差异为-0.020 mm(95%CI -0.110至0.071;p=0.671),无显著差异。
  • 髋臼假体迁移和患者报告结局指标均未见差异。

核心结论

  • 五年时维生素E掺杂聚乙烯内衬与高交联聚乙烯内衬之间、以及32 mm与36 mm股骨头之间均未发现股骨头穿透的显著差异。

研究设计与样本

  • 计划行全髋关节置换术的患者被随机分配接受维生素E掺杂聚乙烯内衬或高交联聚乙烯内衬,并搭配32 mm或36 mm金属股骨头,采用2×2析因设计形成四个干预组。
  • 筛查220例患者,127例纳入研究,116例接受了分配干预,94例在五年时有结果可供分析。
  • 采用放射立体照相测量分析在基线、术后3、12、24和60个月测量股骨头穿透和髋臼假体迁移。
  • 在基线、3、12、36和60个月评估Harris髋关节评分、加州大学洛杉矶分校(UCLA)活动评分、欧洲五维健康量表(EQ-5D)和36项简表健康调查问卷(SF-36)。

主要发现

  • 五年时股骨头穿透在两种内衬材料间相似,维生素E掺杂聚乙烯 vs 高交联聚乙烯为-0.084 mm(95%CI -0.173至0.005;p=0.064)。
  • 五年时股骨头穿透在两种股骨头尺寸间相似,32 mm vs 36 mm为-0.020 mm(95%CI -0.110至0.071;p=0.671)。
  • 髋臼假体迁移和患者报告结局指标均未发现差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm). METHODS: Patients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal head (four intervention groups in a 2 × 2 factorial design). Head penetration and acetabular component migration were measured using radiostereometric analysis at baseline, three, 12, 24, and 60 months postoperatively. The Harris Hip Score, University of California, Los Angeles (UCLA) Activity Score, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey questionnaire (SF-36) were assessed at baseline, three, 12, 36, and 60 months. RESULTS: Of 220 screened patients, 127 were included in this study. In all, 116 received the allocated intervention, and 94 had their results analyzed at five years. Head penetration was similar between liner materials and head sizes at five years, vE-PE versus XLPE was -0.084 mm (95% confidence interval (CI) -0.173 to 0.005; p = 0.064), and 32 mm versus 36 mm was -0.020 mm (95% CI -0.110 to 0.071; p = 0.671), respectively. No differences were found in acetabular component migration or in the patient-reported outcome measures. CONCLUSION: No significant difference in head penetration was found at five years between vE-PE and XLPE liners, nor between 32 mm and 36 mm heads. Cite this article: Bone Joint J 2020;102-B(10):1303-1310.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kjærgaard K, Ding M, Jensen C, et al. Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial. Bone Joint J. 2020. PMID: 32993343. doi:10.1302/0301-620X.102B10.BJJ-2020-0138.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。