患者特异性3D打印钻导板用于椎弓根与侧块螺钉置入的准确性:76条颈椎与胸椎螺钉轨迹分析

Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories.
PubMed 文献 · Spine (Phila Pa 1976) · 2021-01-01

单中心回顾性病例系列纳入15例使用患者特异性3D打印钻导板的颈胸段后路脊柱融合术患者,将术后模型与术前3D手术计划配准,量化76条螺钉轨迹的进钉点和角度偏差。总体进钉点偏差1.40±0.81 mm、角度偏差6.70±3.77°,矢状面角度偏差显著高于轴向面(P=0.02);全部螺钉位置均判定为「安全」(100%),未发生神经血管损伤、关节突关节侵犯或椎弓根壁侵犯。作者认为3D虚拟规划联合3D打印患者特异性钻导板在颈段与上胸段椎弓根及侧块螺钉置入中似乎安全且准确。

要点

  • 76条颈椎与上胸椎螺钉轨迹总体进钉点偏差1.40±0.81 mm,角度偏差6.70±3.77°。
  • 矢状面角度偏差显著高于轴向面(P=0.02)。
  • 全部螺钉位置判定为「安全」(100%),无神经血管损伤、关节突关节侵犯或椎弓根壁侵犯。

核心结论

  • 3D虚拟规划与3D打印患者特异性钻导板在颈段与上胸段脊柱椎弓根及侧块螺钉置入中似乎安全且准确。
  • 定量3D偏差分析证实螺钉位置相对于3D手术计划是准确的。

研究设计与样本

  • 单中心回顾性病例系列,纳入15例接受使用患者特异性3D打印钻导板的颈胸段后路脊柱融合手术的患者。
  • 对骨与螺钉进行分割后,将术后模型叠加到术前手术计划上,通过测量进钉点偏差与角度偏差量化实际螺钉轨迹的准确性。
  • 证据等级为4级。

主要发现

  • 全部76条螺钉轨迹的进钉点偏差为1.40±0.81 mm,角度偏差为6.70±3.77°。
  • 矢状面角度偏差显著高于轴向面(P=0.02)。
  • 全部螺钉位置均判定为「安全」(100%),未出现神经血管损伤、关节突关节侵犯或椎弓根壁侵犯。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Single-center retrospective case series. OBJECTIVE: The purpose of this study was to assess the safety and accuracy of three-dimensional (3D)-printed individualized drill guides for pedicle and lateral mass screw insertion in the cervical and upper-thoracic region, by comparing the preoperative 3D surgical plan with the postoperative results. SUMMARY OF BACKGROUND DATA: Posterior spinal fusion surgery can provide rigid intervertebral fixation but screw misplacement involves a high risk of neurovascular injury. However, modern spine surgeons now have tools such as virtual surgical planning and 3D-printed drill guides to facilitate spinal screw insertion. METHODS: A total of 15 patients who underwent posterior spinal fusion surgery involving patient-specific 3D-printed drill guides were included in this study. After segmentation of bone and screws, the postoperative models were superimposed onto the preoperative surgical plan. The accuracy of the realized screw trajectories was quantified by measuring the entry point and angular deviation. RESULTS: The 3D deviation analysis showed that the entry point and angular deviation over all 76 screw trajectories were 1.40 ± 0.81 mm and 6.70 ± 3.77°, respectively. Angular deviation was significantly higher in the sagittal plane than in the axial plane (P = 0.02). All screw positions were classified as "safe" (100%), showing no neurovascular injury, facet joint violation, or violation of the pedicle wall. CONCLUSIONS: 3D virtual planning and 3D-printed patient-specific drill guides appear to be safe and accurate for pedicle and lateral mass screw insertion in the cervical and upper-thoracic spine. The quantitative 3D deviation analyses confirmed that screw positions were accurate with respect to the 3D-surgical plan.Level of Evidence: 4.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。