文献速递脊柱外科小儿骨科

青少年特发性脊柱侧凸术前术后胸廓参数的三维分析:同步双平面放射摄影扫描技术,至少2年随访

Three-Dimensional Analysis of Preoperative and Postoperative Rib Cage Parameters by Simultaneous Biplanar Radiographic Scanning Technique in Adolescent Idiopathic Scoliosis: Minimum 2-Year Follow-Up.
PubMed 文献 · Spine (Phila Pa 1976) · 2021-01-01

前瞻性研究纳入67例Lenke 1或2型青少年特发性脊柱侧凸患者,采用同步双平面放射摄影扫描技术(EOS)重建三维图像,比较术前与术后2年随访时的脊柱及胸廓参数变化。结果显示主胸弯和近端胸弯均显著矫正,胸椎后凸显著增加,多个胸廓参数术后显著改变,仅肋骨椎体角差异无显著差异。作者认为三维重建有助于评估术前术后胸廓畸形。

要点

  • 主胸弯从51°矫正至15°,近端胸弯从30°矫正至17°,均P<0.0001。
  • 胸椎后凸(T4-T12)从13°增加至18°,P<0.0001。
  • 肋骨椎体角差异术前术后无显著差异(P=0.32)。

核心结论

  • 使用双平面站立立体放射摄影进行胸廓三维重建,有助于评估青少年特发性脊柱侧凸患者术前和术后的胸廓畸形。

研究设计与样本

  • 前瞻性研究,纳入67例接受手术的Lenke 1或2型青少年特发性脊柱侧凸患者(59例女性,8例男性),平均年龄14.4岁(范围11-17岁),所有患者行后路矫正融合术,基于节段性椎弓根固定并采用棒旋转手法。
  • 术前及术后2年随访时采用同步双平面放射摄影扫描技术(EOS)进行三维图像评估。

主要发现

  • 主胸弯从51°矫正至15°,近端胸弯从30°矫正至17°,均P<0.0001。
  • 主胸弯顶椎旋转从12°矫正至5°,P<0.0001;胸椎后凸(T4-T12)从13°增加至18°,P<0.0001。
  • 最大厚度、胸廓指数和肋骨隆起在术前与术后图像间差异显著,P<0.01。
  • T8-10表面脊柱穿透指数和终末胸廓隆起比术后显著下降,P<0.05。
  • 胸骨椎体角术后显著减小(P<0.0001),但肋骨椎体角差异术前术后无显著差异(P=0.32);椎体侧方偏移和胸廓体积术后显著增加(P<0.0001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Prospective study. OBJECTIVE: This study aimed to investigate the changes in rib cage deformity in adolescent idiopathic scoliosis (AIS) by comparing the preoperative and postoperative three-dimensional (3D) reconstruction images using simultaneous biplanar radiographic scanning technique (EOS) (EOS Imaging, Paris, France). SUMMARY OF BACKGROUND DATA: EOS data are limited for the analyses of preoperative and postoperative rib cage deformity. METHODS: A total of 67 Lenke type 1 or 2 AIS patients who underwent surgery (59 females and 8 males) were enrolled in this study. The mean patient age was 14.4 years (range: 11-17 yr). In all patients, posterior corrective fusion was performed with a rod rotation maneuver based on segmental pedicle fixation. Spinal parameters (scoliosis and kyphosis) and rib cage parameters (max thickness, thoracic index (TI), rib hump (RH), surface spinal penetration index (sSPI), end thoracic hump ratio, vertebra-sternum angle, rib vertebral angle difference at the apex, and vertebral lateral decentering), were measured. 3D images were assessed preoperatively and postoperatively at 2-year follow-up. RESULTS: Both main thoracic (MT) and proximal thoracic scoliosis were significantly corrected (51° to 15°, 30° to 17°, P < 0.0001). The rotation of MT apical vertebrae was also significantly corrected (12° to 5°, P < 0.0001). Thoracic kyphosis (T4-T12) significantly increased (13° to 18°, P < 0.0001). Besides, max thickness, TI, and RH demonstrated significant differences between preoperative and postoperative images (P < 0.01). T8-10 sSPI and end thoracic hump ratio decreased significantly postoperatively (P < 0.05). Although surgery significantly decreased vertebra-sternum angle (P < 0.0001), no significant difference was observed between the preoperative and postoperative rib vertebral angle difference (P = 0.32). Following the surgery, vertebral lateral decentering and rib cage volume were significantly increased (P < 0.0001). CONCLUSIONS: 3D reconstruction of the rib cage using biplanar standing stereoradiography is useful to evaluate preoperative and postoperative rib cage deformity in patients with AIS.Level of Evidence: 2.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Machino M, Kawakami N, Ohara T, et al. Three-Dimensional Analysis of Preoperative and Postoperative Rib Cage Parameters by Simultaneous Biplanar Radiographic Scanning Technique in Adolescent Idiopathic Scoliosis: Minimum 2-Year Follow-Up. Spine (Phila Pa 1976). 2021. PMID: 33038199. doi:10.1097/BRS.0000000000003743

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。