腰椎小梁CT衰减值测量在预测骨质疏松性压缩骨折中的价值:L4小梁感兴趣区最相关吗?
这项回顾性研究纳入188例符合纳入标准的患者,评估腰椎椎体小梁感兴趣区(t-ROI)CT衰减值预测骨质疏松性压缩骨折(OCF)的效用,并与脊柱双能X线吸收测定(DXA)比较。L4 ROI衰减值预测OCF的曲线下面积为0.798,最佳截断值为90.5 HU,灵敏度88.8%、特异度60.6%,且与OCF率显著相关(r=-0.545,P<0.001)。作者认为简单t-ROI CT衰减值是对比DXA T值的准确预测工具,L4 t-ROI衰减值是最相关的测量。
要点
- L4 ROI衰减值预测OCF的AUC为0.798,最佳截断值90.5 HU,灵敏度88.8%、特异度60.6%。
- L4 ROI衰减值与OCF率显著相关(r=-0.545,P<0.001)。
- 压缩骨折数量与L4 ROI衰减值独立相关(决定系数R2=0.286;P<0.001)。
核心结论
- 简单t-ROI CT衰减值是对比DXA T值的准确预测OCF工具。
- L4 t-ROI衰减值是预测OCF最相关的测量,可作为DXA的替代,并能预测压缩骨折的数量和发生率。
- 脊柱外科医生应了解L4 t-ROI衰减值,以便在为老年患者群进行脊柱手术时实现成功融合。
研究设计与样本
- 回顾性研究,纳入188例符合纳入标准的患者。
- 确定最相关水平简单t-ROI衰减值预测OCF的最佳截断值。
- 评估最相关水平简单t-ROI衰减值与OCF率的相关性,并研究压缩骨折数量与最相关水平简单t-ROI衰减值的关联。
主要发现
- L4 ROI衰减值预测OCF最准确,曲线下面积为0.798。
- L4 ROI衰减值最佳截断点为90.5 HU,灵敏度88.8%、特异度60.6%。
- L4 ROI衰减值与OCF率显著相关(r=-0.545,P<0.001)。
- 压缩骨折数量与L4 ROI衰减值独立相关(决定系数R2=0.286;P<0.001)。
关键数值与推荐
- L4 ROI衰减值预测OCF的AUC为0.798。
- L4 ROI衰减值最佳截断值为90.5 HU,灵敏度88.8%、特异度60.6%。
- L4 ROI衰减值与OCF率的相关系数r=-0.545,P<0.001。
- 压缩骨折数量与L4 ROI衰减值的决定系数R2=0.286,P<0.001。
临床怎么用
- 作者认为L4 t-ROI衰减值可作为DXA的替代,用于预测骨质疏松性压缩骨折的数量和发生率。
- 作者认为脊柱外科医生应了解L4 t-ROI衰减值,以便在为老年患者群进行脊柱手术时实现成功融合。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective study. OBJECTIVE: The aim of this study was to evaluate the usefulness of computed tomography (CT) attenuation in defining trabecular region-of-interest (t-ROI) at lumbar vertebral body in the assessment of osteoporotic compression fracture (OCF) compared to spinal dual x-ray absorptiometry (DXA). SUMMARY OF BACKGROUND DATA: Even though osteoporosis was not diagnosed in the bone mineral density measurement using DXA, we often experienced cases where the screw was weakly inserted due to low bone quality during screw insertion. METHODS: A total of 188 patients who met the inclusion criteria were enrolled. We determined best cutoff value of the simple t-ROI attenuation at the most relevant level for predicting OCF. We assessed correlations between the simple t-ROI attenuation at the most relevant level and OCF rate, and investigate the association between the number of compression fracture and simple t-ROI attenuation at the most relevant level. RESULTS: L4 ROI attenuation is the most accurate measurement for predicting osteoporotic compression fracture with an area under the curve of 0.798. The optimal cutoff point of L4 ROI attenuation was measured at 90.5 HU with 88.8% and 60.6% sensitivity and specificity, respectively. L4 ROI attenuation was significantly correlated with the osteoporotic compression fracture rate (r = -0.545, P < 0.001). The number of compression fracture (coefficient of determination R2 = 0.286; P < 0.001) was independently correlated with L4 ROI attenuation. CONCLUSION: Simple t-ROI computed tomography attenuation is an accurate measurement tool in predicting OCF compared to DXA T-score. The value of L4 t-ROI attenuation is the most relevant measurement for predicting osteoporotic compression fracture, is an alternative to DXA, and can predict the number and rate of compression fractures. Spine surgeons should be aware of L4 t-ROI attenuation to make successful fusion in spine surgery for elderly patients group.Level of Evidence: 3.
引用
- Lee BJ, Koo HW, Yoon SW, et al. Usefulness of Trabecular CT Attenuation Measurement of Lumbar Spine in Predicting Osteoporotic Compression Fracture: Is the L4 Trabecular Region of Interest Most Relevant? Spine (Phila Pa 1976). 2021. PMID: 33065695. doi:10.1097/BRS.0000000000003756
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。