文献速递运动医学小儿骨科

基于锚钉的股骨固定用于保留骺板的内侧髌股韧带重建:与肌腱固定螺钉固定的时间零点生物力学比较

Anchor-Based Femoral Fixation for Physeal-Sparing Medial Patellofemoral Ligament Reconstruction: A Time-Zero Biomechanical Comparison With Tenodesis Screw Fixation.
PubMed 文献 · Am J Sports Med · 2020-09-10

研究在猪股骨模型中比较锚钉与肌腱固定螺钉固定内侧髌股韧带移植物的时间零点生物力学表现,每组9例。结果显示锚钉组循环刚度与螺钉组相当,但位移显著更小,且失败载荷变异性更低。作者认为单枚锚钉股骨固定是传统肌腱固定螺钉固定的可行替代方案。

要点

  • 锚钉组循环刚度与肌腱固定螺钉组相当(第1000次循环时TS组68.3±6.3 N/mm,DLA组71.4±6.4 N/mm,KA组74.3±7.9 N/mm)。
  • 第1000次循环时锚钉组位移显著小于螺钉组(TS组7.7±4.2 mm vs DLA组3.7±0.4 mm和KA组4.3±0.6 mm)。
  • 极限失败载荷组间无显著差异,但TS组9例中3例在低于天然内侧髌股韧带平均失败载荷时失败。

核心结论

  • 与肌腱固定螺钉组相比,基于锚钉的固定产生等效的循环刚度、改善的载荷-位移特性,并在猪尸体模型中具有更低的失败载荷变异性。

研究设计与样本

  • 对照实验室研究,使用27个新鲜冷冻猪远端股骨和牛肌腱进行内侧髌股韧带重建,分三组:4.5 mm生物复合材料双载螺纹锚钉(DLA组)、3.9 mm生物复合材料无结螺纹锚钉(KA组)或传统7×23 mm生物复合材料肌腱固定螺钉(TS组)。

主要发现

  • 第1000次循环时平均循环刚度:TS组68.3±6.3 N/mm,DLA组71.4±6.4 N/mm,KA组74.3±7.9 N/mm,组间比较无显著差异。
  • 第1000次循环时平均构造位移:TS组7.7±4.2 mm,显著大于DLA组3.7±0.4 mm和KA组4.3±0.6 mm。
  • 极限失败载荷在锚钉组与肌腱固定螺钉组之间无显著差异,但TS组9例构造中3例在低于天然内侧髌股韧带平均失败载荷时失败。

临床怎么用

  • 作者认为,使用单枚锚钉(4.5或3.9 mm螺纹)进行内侧髌股韧带移植物的股骨固定是传统肌腱固定螺钉固定的可行替代方案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Open physes and trochlear/notch geometries in pediatric patients limit the safe corridor for femoral interference screw graft fixation during medial patellofemoral ligament (MPFL) reconstruction. Accordingly, interest is increasing in anchor-based fixation, but biomechanical validation is deficient. PURPOSE: To compare anchor-based and tenodesis screw femoral fixation of MPFL grafts in a time-zero biomechanical model. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty-seven fresh-frozen porcine distal femurs were potted for testing in an electromechanical load frame, while bovine tendons were used for MPFL grafts. Reconstructions were performed with 1 of 3 femoral fixation strategies: 4.5-mm biocomposite double-loaded threaded anchor (DLA group), 3.9-mm biocomposite knotless threaded anchor (KA group), or traditional 7 × 23-mm biocomposite tenodesis screw (TS group). For testing, femoral specimens were oriented and secured in the mechanical testing apparatus such that actuator tensile pull re-created the normal MPFL trajectory. Specimens underwent 10 cycles of 5- to 15-N loading at 1-Hz preconditioning, followed by 1000 cycles of 10- to 50 N-loading at 1 Hz. After cyclic loading, all specimens were loaded to failure at 305 mm/min. The average cyclic construct stiffness, displacement, and load-to-failure data between the 3 groups were compared using analysis of variance (ANOVA) with the significance level set at P < .05. RESULTS: Average cyclic construct stiffnesses were comparable across groups per repeated-measures ANOVA analysis: 68.3 ± 6.3, 71.4 ± 6.4, and 74.3 ± 7.9 N/mm for TS, DLA, and KA groups, respectively (at cycle 1000). Average construct displacements at cycles 100 and 1000 were significantly less in the anchor versus tenodesis screw groups per ANOVA and Tukey post hoc analysis: 7.7 ± 4.2 mm for the TS group versus 3.7 ± 0.4 and 4.3 ± 0.6 mm for the DLA and KA groups, respectively (at cycle 1000). There was no significant difference in ultimate failure loads between the anchor and tenodesis screw groups, but 3 of 9 TS constructs failed at loads below the average failure load of the native MPFL. CONCLUSION: Compared with the tenodesis group, anchor-based fixation produced constructs with equivalent cyclic stiffnesses, improved load-displacement characteristics, and had less failure load variability in the porcine cadaveric model. CLINICAL RELEVANCE: Femoral fixation of the MPFL graft with a single anchor (4.5 or 3.9 mm threaded) is a viable alternative to traditional tenodesis screw fixation.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Johnston TR, Liles J, Riboh J, et al. Anchor-Based Femoral Fixation for Physeal-Sparing Medial Patellofemoral Ligament Reconstruction: A Time-Zero Biomechanical Comparison With Tenodesis Screw Fixation. Am J Sports Med. 2020. PMID: 32909820. doi:10.1177/0363546520951523

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。