文献速递运动医学关节外科

人体前交叉韧带自体移植物重塑的定量评估:三维UTE-T2*成像研究

Quantitative Assessment of In Vivo Human Anterior Cruciate Ligament Autograft Remodeling: A 3-Dimensional UTE-T2* Imaging Study.
PubMed 文献 · Am J Sports Med · 2020-09-11

这项前瞻性病例系列研究纳入12例(分析10例)初次前交叉韧带重建患者,在术后1、3、6、9、12个月行UTE-T2* MRI。移植物T2*值从1个月5.5±2.1 ms升至6个月10.0±2.9 ms(P=.001),12个月降至8.1±2.0 ms;作者认为UTE-T2* MRI未来可能有助于无创评估移植物成熟度。

要点

  • 移植物T2*值1个月为5.5±2.1 ms,6个月升至10.0±2.9 ms(P=.001),12个月降至8.1±2.0 ms。
  • T2*伤侧/健侧比值1个月为62.8%±22.9%,6个月升至111.1%±23.9%(P=.001),12个月降至92.8%±29.8%。
  • 各亚区域T2*值均于6个月达峰后逐渐下降,亚区域间差异无统计学意义(P>.05)。

核心结论

  • 作者认为,在这项初步研究中,前交叉韧带自体移植物T2*值在1至6个月间出现82%的统计学显著升高,随后在6至12个月间下降约19%。
  • 作者认为,UTE-T2* MRI未来可能为重塑中的前交叉韧带移植物状态提供独特见解,并可能提高在重返运动前无创评估移植物成熟度的能力。

研究设计与样本

  • 前瞻性病例系列研究,证据等级4级;纳入12例14-45岁接受腘绳肌腱或骨-髌腱-骨自体移植物初次前交叉韧带重建(伴或不伴半月板修复)的患者。
  • 排除既往任一侧膝关节损伤或手术史者;患者于术后1、3、6、9、12个月返回行UTE MRI,1个月时成像包括对侧膝关节。
  • MRI序列包括高分辨率三维梯度回波序列和4回波T2-UTE序列(层厚1 mm;重复时间20 ms;回波时间0.3、3.3、6.3和9.3 ms)。
  • 在高分辨率序列上分割所有包含关节内前交叉韧带的层面以生成体积感兴趣区(ROI),ROI按标准化方法分为近端/远端和核心/外周亚ROI,随后进行体素对体素配准生成各时间点T2*图;由第二位评估者重复该过程以评估观察者间信度。
  • 采用重复测量和单因素方差分析评估ROI及亚ROI间平均T2*值和T2*伤侧/T2*健侧平均比值的统计学差异,P<.05表示有统计学意义。

主要发现

  • 12例患者入组,2例退出,最终10例纳入分析(腘绳肌腱7例,骨-髌腱-骨3例)。
  • T2*值的观察者间信度良好至优秀(组内相关系数0.84;95%CI 0.59-0.94;P<.001)。
  • T2*值从1个月5.5±2.1 ms(均值±标准差)升高至6个月10.0±2.9 ms(P=.001),随后下降至12个月8.1±2.0 ms(与1个月比较P=.129;与6个月比较P=.094)。
  • T2*伤侧/T2*健侧平均比值从1个月62.8%±22.9%升高至6个月111.1%±23.9%(P=.001),随后下降至12个月92.8%±29.8%(与1个月比较P=.110;与6个月比较P=.086)。
  • 亚ROI显示类似的T2*升高直至6个月达峰,随后逐渐下降至12个月时间点;亚ROI间差异无统计学意义(P>.05)。

临床怎么用

  • 作者认为,UTE-T2* MRI未来可能为重塑中的前交叉韧带移植物状态提供独特见解,并可能提高在重返运动前无创评估移植物成熟度的能力。

局限性

  • 作者称本研究为初步研究。
  • 12例入组患者中2例退出,最终仅10例纳入分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The timing of return to play after anterior cruciate ligament (ACL) reconstruction is still controversial due to uncertainty of true ACL graft state at the time of RTP. Recent work utilizing ultra-short echo T2* (UTE-T2*) magnetic resonance imaging (MRI) as a scanner-independent method to objectively and non-invasively assess the status of in vivo ACL graft remodeling has produced promising results. PURPOSE/HYPOTHESIS: The purpose of this study was to prospectively and noninvasively investigate longitudinal changes in T2* within ACL autografts at incremental time points up to 12 months after primary ACL reconstruction in human patients. We hypothesized that (1) T2* would increase from baseline and initially exceed that of the intact contralateral ACL, followed by a gradual decline as the graft undergoes remodeling, and (2) remodeling would occur in a region-dependent manner. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Twelve patients (age range, 14-45 years) who underwent primary ACL reconstruction with semitendinosus tendon or bone-patellar tendon-bone autograft (with or without meniscal repair) were enrolled. Patients with a history of previous injury or surgery to either knee were excluded. Patients returned for UTE MRI at 1, 3, 6, 9, and 12 months after ACL reconstruction. Imaging at 1 month included the contralateral knee. MRI pulse sequences included high-resolution 3-dimensional gradient echo sequence and a 4-echo T2-UTE sequence (slice thickness, 1 mm; repetition time, 20 ms; echo time, 0.3, 3.3, 6.3, and 9.3 ms). All slices containing the intra-articular ACL were segmented from high-resolution sequences to generate volumetric regions of interest (ROIs). ROIs were divided into proximal/distal and core/peripheral sub-ROIs using standardized methods, followed by voxel-to-voxel registration to generate T2* maps at each time point. This process was repeated by a second reviewer for interobserver reliability. Statistical differences in mean T2* values and mean ratios of T2*inj/T2*intact (ie, injured knee to intact knee) among the ROIs and sub-ROIs were assessed using repeated measures and one-way analyses of variance. P < .05 represented statistical significance. RESULTS: Twelve patients enrolled in this prospective study, 2 withdrew, and ultimately 10 patients were included in the analysis (n = 7, semitendinosus tendon; n = 3, bone-patellar tendon-bone). Interobserver reliability for T2* values was good to excellent (intraclass correlation coefficient, 0.84; 95% CI, 0.59-0.94; P < .001). T2* values increased from 5.5 ± 2.1 ms (mean ± SD) at 1 month to 10.0 ± 2.9 ms at 6 months (P = .001), followed by a decline to 8.1 ± 2.0 ms at 12 months (P = .129, vs 1 month; P = .094, vs 6 months). Similarly, mean T2*inj/T2*intact ratios increased from 62.8% ± 22.9% at 1 month to 111.1% ± 23.9% at 6 months (P = .001), followed by a decline to 92.8% ± 29.8% at 12 months (P = .110, vs 1 month; P = .086, vs 6 months). Sub-ROIs exhibited similar increases in T2* until reaching a peak at 6 months, followed by a gradual decline until the 12-month time point. There were no statistically significant differences among the sub-ROIs (P > .05). CONCLUSION: In this preliminary study, T2* values for ACL autografts exhibited a statistically significant increase of 82% between 1 and 6 months, followed by an approximate 19% decline in T2* values between 6 and 12 months. In the future, UTE-T2* MRI may provide unique insights into the condition of remodeling ACL grafts and may improve our ability to noninvasively assess graft maturity before return to play.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Warth RJ, Zandiyeh P, Rao M, et al. Quantitative Assessment of In Vivo Human Anterior Cruciate Ligament Autograft Remodeling: A 3-Dimensional UTE-T2* Imaging Study. Am J Sports Med. 2020. PMID: 32915640. doi:10.1177/0363546520949855

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。