文献速递关节外科

非骨水泥全髋关节置换术采用32毫米钴铬球头配高交联聚乙烯及锥形纤维金属近端涂层股骨柄的至少10年随访

Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty With a 32-mm Cobalt-Chromium Head on Highly Cross-Linked Polyethylene and a Tapered, Fiber Metal Proximally Coated Femoral Stem.
PubMed 文献 · J Arthroplasty · 2020-08-31

研究评估57例非骨水泥全髋关节置换术使用32毫米钴铬球头、重熔高交联聚乙烯及锥形纤维金属近端涂层股骨柄的中长期结果。平均随访12年,Merle d'Aubigné与Postel评分从术前10.7分显著改善至术后15.6分(P < .001),无骨溶解,假体存活率95%(95%CI 85%-98%)。结论认为该组合磨损低、股骨柄长期结果良好。

要点

  • 平均随访12年,Merle d'Aubigné与Postel评分从术前10.7分改善至术后15.6分(P < .001)。
  • 总球头穿透率为0.05毫米/年,稳态磨损率为0.01毫米/年。
  • 以翻修为终点的12年Kaplan-Meier生存率为95%(95%CI 85%-98%)。

核心结论

  • 32毫米钴铬球头配重熔高交联聚乙烯表现出低磨损特性,锥形纤维金属近端涂层股骨柄在长期随访中显示良好结果。

研究设计与样本

  • 2004年10月至2006年12月共行57例非骨水泥全髋关节置换术,使用重熔高交联聚乙烯、32毫米钴铬球头及锥形纤维金属近端涂层股骨柄,平均随访12年。

主要发现

  • Merle d'Aubigné与Postel评分从术前10.7分显著改善至术后15.6分(P < .001)。
  • 假体周围未见骨溶解,所有病例股骨柄固定均显示稳定的骨长入。
  • 全部股骨柄中46%出现第三度应力遮挡。
  • 总球头穿透率为0.05毫米/年,稳态磨损率为0.01毫米/年。
  • 以翻修为终点的12年Kaplan-Meier生存率为95%(95%CI 85%-98%)。

关键数值与推荐

  • 临床评估采用Merle d'Aubigné与Postel评分系统。
  • 影像学采用骨盆与股骨标准正侧位X线片(非负重位)分析,并用计算机化方法测量二维股骨头穿透。
  • 稳态磨损率基于术后第一年至末次随访的X线片测量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The clinical and radiographic results of cementless total hip arthroplasty using a 32-mm cobalt-chromium head on remelted highly cross-linked polyethylene (HXLPE) and a tapered, fiber metal proximally coated femoral stem were evaluated at a mean follow-up of 12 years. METHODS: A total of 57 cementless total hip arthroplasties using remelted HXLPE combined with a 32-mm cobalt-chromium head, and a tapered, fiber metal proximally coated femoral stem were performed from October 2004 to December 2006. Clinical evaluation was performed using the Merle d'Aubigné and Postel scoring system. Standardized anteroposterior and lateral radiographs of the pelvis and femur without weight-bearing were analyzed. Radiographic measurements of two-dimensional femoral head penetration into the polyethylene were performed with a computerized method. The steady-state wear rates were measured based on the radiographs from the first year after surgery to the final follow-up. RESULTS: The mean Merle d'Aubigné and Postel score improved significantly from 10.7 points preoperatively to 15.6 postoperatively (P < .001). No osteolysis was found around the implant. Stem fixation in all cases showed stable bone ingrowth. Third-degree stress shielding was found in 46% of all stems. The total head penetration rate was 0.05 mm/y, and the steady-state wear rate was 0.01 mm/y. The Kaplan-Meier survivorship with the end point of revision was 95% (95% confidence interval, 85%-98%) at 12 years. CONCLUSION: A 32-mm cobalt-chromium head on remelted HXLPE demonstrated low wear properties, and a tapered, fiber metal proximally coated femoral stem showed good results at long-term follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Naito Y, Hasegawa M, Tone S, et al. Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty With a 32-mm Cobalt-Chromium Head on Highly Cross-Linked Polyethylene and a Tapered, Fiber Metal Proximally Coated Femoral Stem. J Arthroplasty. 2020. PMID: 32950339. doi:10.1016/j.arth.2020.08.055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。