全膝关节置换术中使用术中压力传感器进行膝关节平衡能否改善临床结局?一项至少两年随访的对比研究
该研究比较了207例手工平衡(MB)与222例传感器平衡(SB)全膝关节置换术(TKA)的临床结局。主要终点KOOS4聚合均值变化在两组间无显著差异(MB 42.4 vs SB 41.5,均差0.9,95%CI -2.6至4.4,P=0.62)。SB组平衡操作比例显著更高(55.9% vs 16.9%,P<0.01),但再手术率和僵硬手法松解率无显著差异。
要点
- 传感器平衡TKA与手工平衡TKA在KOOS4聚合均值变化上无显著差异(均差0.9,95%CI -2.6至4.4,P=0.62)。
- 传感器平衡组需要更多平衡操作(55.9% vs 16.9%,P<0.01)。
- 两组再手术率(1.4% vs 1.4%,P=0.71)和僵硬手法松解率(3.7% vs 4.4%,P=0.69)无显著差异。
核心结论
- 使用传感器实现膝关节平衡并未改善临床结局,尽管显著增加了实现平衡所需的手术干预数量。
- 传感器未改变翻修手术率或手法松解需求。
- 精确软组织平衡是否能改善假体生存率和关节生物力学仍有待确定。
研究设计与样本
- 对比研究,连续纳入207例手工平衡TKA与222例传感器平衡TKA,手术时间在2014年4月至2017年4月之间。
- 所有手术由单一外科医生完成,使用相同假体。
- 主要终点为术前至术后两年间KOOS4四个子量表的聚合均值变化。
主要发现
- KOOS4聚合均值变化:手工平衡组42.4(标准差29.1) vs 传感器平衡组41.5(标准差25.0),均差0.9(95%CI -2.6至4.4,P=0.62),无显著差异。
- 平衡操作比例:传感器平衡组55.9% vs 手工平衡组16.9%(P<0.01),传感器组显著更高。
- 再手术率:传感器平衡组1.4% vs 手工平衡组1.4%(P=0.71),无显著差异。
- 僵硬手法松解率:传感器平衡组3.7% vs 手工平衡组4.4%(P=0.69),无显著差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: It is undetermined whether using sensors for knee balancing in total knee arthroplasty (TKA) improves patient outcomes. The purpose of this study was to compare clinical outcomes of sensor balance (SB) with manual balance (MB) TKA with a minimum two-year follow-up. METHODS: A consecutive series of 207 MB TKAs was compared with 222 SB TKAs between April 2014 and April 2017. A single surgeon performed all surgeries, using the same prosthesis. The primary end point was the aggregated mean change in four subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS4) between preoperative and two-year time points. Secondary outcomes included mean differences between groups in all five KOOS subscales, proportions of knee balancing procedures, and rates of reoperations including revisions and manipulations for stiffness. RESULTS: The mean changes in the KOOS4 aggregated means for MB TKA (42.4; standard deviation, 29.1) and SB TKA (41.5; standard deviation, 25.0) were not significantly different (mean difference, 0.9; 95% confidence interval: -2.6 to 4.4, P = .62). There were significantly more balancing procedures in the SB group (55.9% versus 16.9%; P < .01). There were no significant differences in the number of reoperations (1.4% SB versus 1.4% MB; P = .71) or manipulations for stiffness (3.7% SB versus 4.4% MB; P = .69). CONCLUSION: The use of sensors in TKA to achieve knee balance did not result in improved clinical outcomes, despite significantly increasing the number of surgical interventions required to achieve a balanced knee. Sensors did not alter the rates of revision surgery or requirements for manipulation. It remains to be determined whether precise soft-tissue balancing improves prosthetic survivorship and joint biomechanics.
引用
- MacDessi SJ, Cohen DA, Wood JA, et al. Does the Use of Intraoperative Pressure Sensors for Knee Balancing in Total Knee Arthroplasty Improve Clinical Outcomes? A Comparative Study With a Minimum Two-Year Follow-Up. J Arthroplasty. 2020. PMID: 32928594. doi:10.1016/j.arth.2020.08.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。