230例感染性全膝关节置换术后清创、抗生素及假体保留的成功率:对假体周围关节感染分类的启示
该多中心回顾性研究纳入230例初次全膝关节置换术后首次假体周围关节感染行清创、抗生素及假体保留(DAIR)的患者,平均随访6.9年,DAIR总体成功率为53.9%。多因素生存分析显示,假体植入小于1年的早期感染DAIR成功率为64%,而假体植入大于1年的晚期血源性感染为38%(OR 1.78,P=0.01);对于晚期感染,金黄色葡萄球菌(OR 4.70,P<0.001)和革兰阴性菌感染(OR 2.56,P=0.031)是DAIR失败的危险因素。
要点
- DAIR总体成功率为53.9%,平均随访6.9年。
- 假体植入小于1年的早期感染DAIR成功率为64%,高于植入大于1年的晚期血源性感染的38%(OR 1.78,P=0.01)。
- 晚期感染中,金黄色葡萄球菌(OR 4.70,P<0.001)和革兰阴性菌(OR 2.56,P=0.031)是DAIR失败的危险因素。
核心结论
- 对于初次全膝关节置换术后超过1年发生的假体周围关节感染,DAIR失败率高,尤其是金黄色葡萄球菌或革兰阴性菌所致者。
- 假体植入时间(age of implant)是DAIR结局的重要预测因素。
研究设计与样本
- 多中心回顾性综述,历时15年,纳入230例因初次全膝关节置换术后首次假体周围关节感染而接受DAIR的患者。
- 收集患者人口学资料、疾病与手术因素、治疗方案及结局,进行单因素和多因素生存分析,并对有预测价值的连续变量行受试者工作特征曲线分析,同时评估多种分类系统对DAIR结局的预测能力。
主要发现
- 患者平均随访6.9年,DAIR总体成功率为53.9%。
- 受试者工作特征曲线分析显示,以假体植入3个月(曲线下面积=0.63)和1年(曲线下面积=0.66)为截断值对结局的预测能力相似。
- 多因素生存分析显示,DAIR在「早期」假体周围关节感染(假体植入<1年)中的成功率为64%,而在「晚期血源性」假体周围关节感染(假体植入>1年)中为38%(OR 1.78,P=0.01)。
- 对于晚期感染(假体植入>1年),金黄色葡萄球菌(OR 4.70,P<0.001)和革兰阴性菌感染(OR 2.56,P=0.031)是DAIR失败的危险因素。
关键数值与推荐
- DAIR总体成功率53.9%(230例)。
- 早期感染(假体植入<1年)DAIR成功率64% vs 晚期血源性感染(假体植入>1年)38%(OR 1.78,P=0.01)。
- 晚期感染中金黄色葡萄球菌OR 4.70(P<0.001),革兰阴性菌OR 2.56(P=0.031),均为DAIR失败危险因素。
- 假体植入3个月(AUC=0.63)和1年(AUC=0.66)截断值对DAIR结局预测能力相似。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prosthetic joint infection (PJI) is the most common cause of failure following total knee arthroplasty (TKA). This study aimed to determine the success of debridement, antibiotics, and implant retention (DAIR) in a large cohort of TKA PJIs and assess the utility of current classification systems in predicting DAIR outcomes in early postoperative, late hematogenous, and chronic PJIs. METHODS: In a multicenter review over 15 years, 230 patients underwent DAIR for first episode PJI following primary TKA. Patient demographics, disease and surgical factors, treatment regime, and outcomes were identified. Univariate and multivariate survival analyses were performed to identify factors associated with successful DAIR. Continuous variables with predictive value were further analyzed using receiver operating characteristic curves. The ability to predict DAIR outcomes of multiple classification systems was also assessed. RESULTS: Patients were followed for an average of 6.9 years. The overall success rate of DAIR was 53.9%. On receiver operating characteristic analysis, 3 months (area under the curve = 0.63) and 1-year age (area under the curve = 0.66) of implant cut-offs was similarly predictive of outcomes. On multivariate survival analysis, DAIR was successful in 64% of "early" PJIs (implant <1 year) vs 38% of "late hematogenous" PJIs (implant >1 year; odds ratio [OR] 1.78, P = .01). For late PJIs (implant >1 year), Staphylococcus aureus (OR 4.70, P < .001) and gram-negative infections (OR 2.56, P = .031) were risk factors for DAIR failure. CONCLUSION: DAIR has a high failure rate in all PJIs occurring more than a year post primary TKA, particularly when caused by S aureus or gram-negative bacteria. The age of implant is an important predictor of DAIR outcomes.
引用
- Zhu MF, Kim K, Cavadino A, et al. Success Rates of Debridement, Antibiotics, and Implant Retention in 230 Infected Total Knee Arthroplasties: Implications for Classification of Periprosthetic Joint Infection. J Arthroplasty. 2020. PMID: 32868114. doi:10.1016/j.arth.2020.07.081
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。