亚洲中年女性全髋关节置换术中经髋臼螺钉置入安全区的体表测量:体内三维模型分析
该研究回顾性分析25例患者共50髋的血管造影CT扫描,重建正常骨盆与血管状态的三维模型,测量经髋臼螺钉安全区的中心角与安全深度,并通过三维模拟手术确定定制髋臼杯各孔的安全螺钉长度。后上区中心角为79.5°,安全区平均安全深度49.8mm(中心角47.7°);模拟手术中,后上区平分线外侧孔的平均安全螺钉长度为43.3mm。作者认为这些定量测量有助于减少全髋关节置换术中经髋臼螺钉固定时的骨盆血管损伤。
要点
- 后上区中心角为79.5°,安全区平均安全深度49.8mm,中心角47.7°。
- 三维模拟手术中,后上区平分线外侧孔的平均安全螺钉长度为43.3mm。
- 作者认为定量测量有助于减少经髋臼螺钉固定时的骨盆血管损伤。
核心结论
- 作者认为,尽管研究受限于使用虚拟计算机程序,所获得的定量测量有助于减少全髋关节置换术中经髋臼螺钉固定时的骨盆血管损伤。
研究设计与样本
- 回顾性分析25例患者共50髋的下肢血管造影CT扫描。
- 使用定制计算机软件重建50髋正常骨盆与血管状态的三维模型。
- 在三维模型上测量经髋臼螺钉安全区的中心角与安全深度,并通过三维模拟手术确认定制髋臼杯各孔的安全螺钉长度。
主要发现
- 后上区中心角测量值为79.5°。
- 安全区平均安全深度为49.8mm,中心角为47.7°。
- 三维模拟手术中,后上区平分线外侧孔的平均安全经髋臼螺钉长度为43.3mm。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文自述研究受限于使用虚拟计算机程序。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although the pelvic vascular injury caused by a transacetabular screw is rare, it is a major local complication of total hip arthroplasty. We aimed to obtain anthropometric data about the safe zone for the placement of transacetabular screws by analyzing the three-dimensional (3D) reconstruction model and determine the safe length of transacetabular screws by performing the 3D simulated surgery. METHODS: We reviewed 50 hips of 25 patients who underwent lower extremity angiographic computed tomography scans retrospectively. We reconstructed the 3D models of 50 hips with normal pelvic bone and vascular status using the customized computer software. We measured the central angle and safe depth of the safe zone of the transacetabular screws on the 3D models. We also performed the 3D simulated surgery to confirm the safe length of screws in each hole of the customized cup implant. RESULTS: The measured central angle of the posterior-superior area was 79.5°. And we determined a mean safe depth of 49.8 mm in the safe zone, with a central angle of 47.7°. During the 3D simulated surgery, we determined a mean safe length of the transacetabular screw of 43.3 mm when applied to a lateral hole on a line bisecting the posterior-superior area. CONCLUSION: Although our study was limited by the use of a virtual computer program, the quantitative measurements obtained can help reduce the incidence of pelvic vascular injury during transacetabular screw fixation in total hip arthroplasty.
引用
- Park JY, Kwon HM, Lee WS, et al. Anthropometric Measurement About the Safe Zone for Transacetabular Screw Placement in Total Hip Arthroplasty in Asian Middle-Aged Women: In Vivo Three-Dimensional Model Analysis. J Arthroplasty. 2020. PMID: 32950340. doi:10.1016/j.arth.2020.08.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。