文献速递关节外科

骨小梁金属锥联合短柄骨水泥型假体在无菌性翻修全膝关节置换术中可获得良好结局

Trabecular Metal Cones Combined With Short Cemented Stem Allow Favorable Outcomes in Aseptic Revision Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-09-02

本研究为回顾性配对比较分析,比较三种重建技术(骨小梁金属锥+短柄骨水泥型假体、骨小梁金属锥+长柄非骨水泥型假体、无锥+长柄非骨水泥型假体)在无菌性翻修全膝关节置换术中的功能结局和假体生存率,至少随访5年。共纳入99例患者,每组33例,平均随访9.3年。骨小梁金属锥+短柄骨水泥型假体组在疼痛、症状、日常生活活动、生活质量及膝关节功能评分改善方面优于其他两组,8年无翻修生存率三组相似。

要点

  • 骨小梁金属锥+短柄骨水泥型假体组在疼痛、症状、日常生活活动、生活质量和膝关节功能评分改善方面优于其他两组。
  • 8年无任何原因翻修生存率:骨小梁金属锥+短柄骨水泥型假体组90.9%,骨小梁金属锥+长柄非骨水泥型假体组84.9%,无锥+长柄非骨水泥型假体组90.6%。
  • 三组生存率相似,但骨小梁金属锥+短柄骨水泥型假体组功能结局更好。

核心结论

  • 在翻修全膝关节置换术中,使用短柄骨水泥型胫骨柄联合骨小梁金属锥与使用长柄非骨水泥型柄联合骨小梁金属锥或金属加强块相比,在至少5年随访时生存率相同,但功能结局更好。

研究设计与样本

  • 回顾性配对比较分析,数据来自2个前瞻性收集的数据库;仅纳入因无菌性原因行翻修全膝关节置换术、使用单一设计旋转铰链膝、至少随访5年的患者。
  • 患者分为3组:骨小梁金属锥+短柄骨水泥型假体组、骨小梁金属锥+长柄非骨水泥型假体组、无锥+长柄非骨水泥型假体组;基于年龄(±5岁)进行配对。
  • 共纳入99例患者,每组33例;平均随访9.3年。

主要发现

  • 骨小梁金属锥+短柄骨水泥型假体组在膝关节损伤和骨关节炎结局评分(KOOS)的疼痛、症状、日常生活活动、生活质量子量表以及膝关节学会评分(KSS)的膝关节、功能评分改善方面,与另外两组相比观察到显著差异,有利于骨小梁金属锥+短柄骨水泥型假体组。
  • 8年无任何原因翻修生存率:骨小梁金属锥+短柄骨水泥型假体组90.9%,骨小梁金属锥+长柄非骨水泥型假体组84.9%,无锥+长柄非骨水泥型假体组90.6%。

关键数值与推荐

  • 8年无任何原因翻修生存率:骨小梁金属锥+短柄骨水泥型假体组90.9%,骨小梁金属锥+长柄非骨水泥型假体组84.9%,无锥+长柄非骨水泥型假体组90.6%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to compare the functional outcomes and implant survivorship at a minimum of 5 years of follow-up of several reconstruction techniques with or without metaphyseal cone and stems of variable length. METHODS: A retrospective comparative matched analysis was performed from 2 prospectively collected databases. Only patients who underwent revision total knee arthroplasty procedures for aseptic causes using a single design of rotating hinge knee with a minimum of 5 years of follow-up were analyzed. Patients were separated into 3 groups: trabecular metal (TM) cones + short cemented stems (TM + short stem [SS]), TM cones + long uncemented stems (TM + long stem [LS]), and no cone (NC) + long uncemented stems (NC + LS). A matching process based on age (±5 years) was realized. RESULTS: About 99 patients were included; 33 in the TM + SS group, 33 in the TM + LS group, and 33 in the NC + LS group. The mean time of follow-up was 9.3 years. A significant difference of the improvement of subscale pain, symptom, activities of daily living, quality of life of the Knee Injury and Osteoarthritis Outcome score and knee, function of the Knee Society Score was observed in favor of TM + SS group compared with the 2 other groups. At 8 years of survivorship, the components free of revision for any cause were 90.9% for the TM + SS group, 84.9% for the TM + LS group, and 90.6% for the NC + LS group. CONCLUSION: The use of a short cemented tibial stem combined with a TM cone in revision total knee arthroplasty offers identical survival rate with better functional outcome compared with the use of a long uncemented stem associated with TM cones or metallic augments at a minimum of 5 years of follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Jacquet C, Ros F, Guy S, et al. Trabecular Metal Cones Combined With Short Cemented Stem Allow Favorable Outcomes in Aseptic Revision Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32978026. doi:10.1016/j.arth.2020.08.058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。