后交叉韧带保留型全膝关节置换术中胫骨垫片矢状面顺应性的渐进选择

Progressive Tibial Bearing Sagittal Plane Conformity in Cruciate-Retaining Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-08-13

研究纳入1731例全膝关节置换术,比较标准后交叉韧带保留型(CR-S)、唇状CR型(CR-L)和前稳定型(AS)胫骨垫片。后交叉韧带平衡时用CR-S或CR-L,缺损时用AS。AS组行走评分显著较低,后不稳定性在CR-S组较高,CR-L组手法复位率最高。5年生存率三组无显著差异。作者认为后交叉韧带平衡时AS与CR功能及5年生存率相似,后交叉韧带完全松解或缺损时AS是合理选择。

要点

  • 后交叉韧带平衡时,AS垫片功能与5年生存率与CR-S及CR-L相似。
  • AS组行走评分显著低于其他组,CR-S组后不稳定性较高。
  • CR-L组手法复位率最高(1.7%、1.3%、0%分别为CR-L、CR-S、AS组)。

核心结论

  • 后交叉韧带平衡时,使用AS垫片与CR-S及CR-L垫片相比提供相似的功能和5年生存率。
  • 术中发现后交叉韧带完全松解或缺损时,使用超顺应AS碟形胫骨组件似乎是合理选择。

研究设计与样本

  • 共1731例全膝关节置换术使用同一膝关节假体设计,其中868例植入标准CR垫片(CR-S),480例使用唇状CR垫片(CR-L),383例使用AS垫片。
  • 后交叉韧带被认为无功能或缺失时放置AS垫片,后交叉韧带平衡时使用CR-S或CR-L垫片。
  • 随访采用膝关节学会评分系统,以无菌性松动为失败定义进行Kaplan-Meier生存分析。

主要发现

  • 末次随访时,膝关节屈曲度、疼痛、功能及上下楼梯评分组间无显著差异。
  • AS组行走评分显著低于其他组。
  • 后不稳定性在CR-S组较高,手法复位率在CR-L组最高(CR-L、CR-S、AS组分别为1.7%、1.3%、0%)。
  • 5年Kaplan-Meier生存率三组间无显著差异(CR-S、CR-L、AS组分别为99%、100%、99%)。

临床怎么用

  • 后交叉韧带平衡时,可选用CR-S或CR-L垫片。
  • 后交叉韧带完全松解或术中发现缺损时,使用超顺应AS碟形胫骨组件似乎是合理选择(作者认为)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We hypothesized that when the posterior cruciate ligament (PCL) is found deficient at total knee arthroplasty (TKA), using an anterior-stabilized (AS) tibial insert would provide similar function and survivorship when compared to using a more traditional cruciate-retaining (CR) bearing when the (PCL) is balanced. METHODS: A total of 1731 TKAs were performed using the same TKA design. Of them, 868 TKAs had a standard CR insert implanted (CR-S), 480 TKAs used a lipped CR insert (CR-L), and 383 TKAs used an AS insert. If the PCL was considered nonfunctional or absent, an AS bearing was placed. When the PCL was balanced, a CR-S or CR-L bearing was used. Follow-up was performed using the Knee Society scoring system. Kaplan-Meier survivorship was used with failure defined as aseptic loosening. RESULTS: At final follow-up, there were no significant differences in knee flexion, pain, function, or stair scores. Walking scores were significantly lower in the AS group. Posterior instability was higher in the CR-S group, whereas the manipulation rate was highest in the CR-L group (1.7%, 1.3%, and 0% for CR-L, CR-S, and AS groups, respectively). Kaplan-Meier survivorship at 5 years demonstrated no significant difference between the 3 groups (99% 100%, and 99% for CR-S, CR-L, and AS groups, respectively). CONCLUSION: Using an AS insert provided similar function and 5-year survivorship as compared to using a CR-S and CR-L tibial insert when the PCL was balanced. Using an ultracongruent AS dished tibial component appears to be a reasonable option when the PCL is completely released or found deficient at operation.