文献速递关节外科

全膝关节翻修术中髌骨钢筋技术增强固定

Patellar Rebar Augmentation in Revision Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-09-01

该研究回顾性分析了2006年至2018年间128例(占1037例翻修全膝关节置换的12.3%)采用背侧髌骨钢筋螺钉技术增强骨水泥固定的翻修髌骨成形术病例。中位随访37个月,术前平均膝关节协会评分(KSS)为50分,末次随访平均KSS为85分;髌骨相关并发症4例(3.1%),研究结束时无假体失败。结论认为该技术适用于有明显空洞性缺损和有限节段性边缘缺损的病例,可扩展髌骨翻修关节置换的适应证。

要点

  • 翻修全膝关节置换中,背侧髌骨钢筋螺钉技术用于128例(12.3%)严重髌骨骨缺损病例。
  • 术前平均KSS 50分改善至末次随访平均85分,髌骨相关并发症4例(3.1%),无假体失败。
  • 该技术适用于明显空洞性缺损和有限节段性边缘缺损,可扩展髌骨翻修适应证。

核心结论

  • 当存在明显空洞性缺损和有限节段性边缘缺损时,髌骨钢筋螺钉增强固定是一种有用的技术,可扩展髌骨翻修关节置换的适应证。

研究设计与样本

  • 回顾性综述,2006年至2018年间在1037例翻修全膝关节置换中,对128例(12.3%)采用背侧髌骨钢筋技术进行髌骨重建,通过系列X线片和前瞻性比较KSS评估临床结局,并评估并发症和需再手术或调整康复的假体失败。

主要发现

  • 128例髌骨翻修中,女性69例、男性59例,平均年龄69.5岁(范围32-83岁),平均随访37个月(范围13-109个月)。
  • 翻修最常见原因为运动学冲突、假体周围关节感染和无菌性松动。
  • 使用钢筋螺钉的中位数为5枚(范围1-13枚)。
  • 术前KSS平均为50分(范围0-90分),末次随访平均KSS为85分(范围54-100分)。
  • 髌骨相关并发症4例(3.1%),研究结束时无假体失败;取出物分析显示所有病例重建的髌骨部件均获得刚性固定。

关键数值与推荐

  • 背侧髌骨钢筋技术适用于有明显空洞性缺损和有限节段性边缘缺损的病例。
  • 使用钢筋螺钉的中位数为5枚(范围1-13枚)。
  • 术前平均KSS 50分(范围0-90分),末次随访平均KSS 85分(范围54-100分)。
  • 髌骨相关并发症发生率为3.1%(4例)。

临床怎么用

  • 作者认为,当存在明显空洞性缺损和有限节段性边缘缺损时,髌骨钢筋螺钉增强固定是一种有用的技术,可扩展髌骨翻修关节置换的适应证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In revision total knee arthroplasty, osteolysis, mechanical abrasion, and infection may leave patellar bone stock severely attenuated with cavitary and/or segmental rim deficiencies that compromise fixation of patellar implant pegs. The purpose of this study was to retrospectively review the use of cortical "rebar" screws to augment cement fixation in revision patelloplasty. METHODS: From 2006 to 2018, dorsal patellar rebar technique was used for patellar reconstruction in 128 of 1037 revision total knee arthroplasty cases (12.3%). Follow-up was achieved with serial radiographs and prospective comparison of Knee Society Scores (KSSs) for clinical outcome. Complications and implant failures requiring reoperation or modified rehabilitation were also assessed. RESULTS: Of the 128 patellar revisions performed using the rebar technique, 69 patients were women and 59 patients were men. The average age of the group was 69.5 years (range, 32-83 years). The mean follow-up of the cohort was 37 months (range, 13-109 months). The most common causes for revision were kinematic conflict, periprosthetic joint infection, and aseptic loosening. The median number of rebar screws used was 5 (range, 1-13). Preoperative KSSs for the study cohort averaged 50 (range, 0-90) At latest follow-up, mean KSS was 85 (range, 54-100). There were 4 patellar-related complications (3.1%) with no implant failures at study conclusion. Retrieval analysis revealed rigid fixation of the reconstructed patellar component in all cases. CONCLUSIONS: Patellar rebar screw augmentation is a useful technique when there are significant cavitary deficiencies and limited segmental rim deficiencies. This technique allows the surgeon to extend indications for patellar revision arthroplasty.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. McPherson EJ, Sherif SM, Dipane MV, et al. Patellar Rebar Augmentation in Revision Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32951925. doi:10.1016/j.arth.2020.08.057

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。