文献速递脊柱外科小儿骨科

使用CAD/CAM设计并结合或不结合有限元建模的支具在2年后带来有效治疗和生活质量:一项随机对照试验

Braces Designed Using CAD/CAM Combined or Not With Finite Element Modeling Lead to Effective Treatment and Quality of Life After 2 Years: A Randomized Controlled Trial.
PubMed 文献 · Spine (Phila Pa 1976) · 2021-01-01

单中心前瞻性随机对照试验纳入120例青少年特发性脊柱侧凸患者,比较CAD/CAM支具与附加有限元建模(FEM)模拟的CAD/CAM支具在2年后的临床结局、三维矫正、依从性和生活质量。

要点

  • CAD-FEM组与CAD组支具内主胸段平均矫正分别为8°和10°(P=0.054),胸腰段/腰段均为12°(P=0.91)。
  • 全部病例中66%满足≤5°进展标准,83%保持<45°,6%接受融合手术。
  • 两亚组在三维矫正、依从性和生活质量上无显著差异(P>0.05)。

核心结论

  • 2年后,使用CAD/CAM设计(加或不加FEM)支具的患者获得满意的临床结局(与BrAIST研究相比)、三维矫正、依从性和生活质量。
  • 支具治疗的更全面优化仍有待完成。

研究设计与样本

  • 单中心前瞻性随机对照试验,招募120例符合脊柱侧凸研究学会支具治疗标准化标准的青少年特发性脊柱侧凸患者。
  • 第一亚组61例(CAD组)使用CAD/CAM设计的支具;第二亚组59例(CAD-FEM组)使用基于脊柱、胸廓和骨盆三维重建构建的患者特异性FEM模拟并优化的支具。
  • 最终44例CAD-FEM组和50例CAD组患者完成研究。

主要发现

  • 支具内平均矫正:主胸段9°(CAD-FEM组8°,CAD组10°,P=0.054);胸腰段/腰段12°(两亚组相同,P=0.91)。
  • 脱支具2年时,所有三维测量较初始畸形的进展<4°。
  • 全部病例中66%(CAD-FEM组30例,CAD组35例)满足≤5°曲线进展标准,83%(CAD-FEM组38例,CAD组43例)保持<45°,6%(CAD-FEM组5例,CAD组1例)接受融合手术。
  • 两亚组在三维矫正、依从性和生活质量上无显著差异(P>0.05)。

局限性

  • 原文结论指出支具治疗的更全面优化仍有待完成。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Single-center prospective randomized controlled trial. OBJECTIVE: The aim of this study was to assess the computer-aided design/manufacturing (CAD/CAM) brace design approach, with and without added finite element modeling (FEM) simulations, after 2 years in terms of clinical outcomes, 3D correction, compliance, and quality of life (QoL). SUMMARY OF BACKGROUND DATA: .: Previous studies demonstrated that braces designed using a combination of CAD/CAM and FEM induced promising in-brace corrections, were lighter, thinner, and covered less trunk surface. Yet, their long-term impact on treatment quality has not been evaluated. METHODS: One-hundred twenty adolescent idiopathic scoliosis patients were recruited following Scoliosis Research Society standardized criteria for brace treatment; 61 patients in the first subgroup (CAD) were given braces designed using CAD/CAM; 59 in the second subgroup (CAD-FEM) received braces additionally simulated and refined using a patient-specific FEM built from 3D reconstructions of the spine, rib cage and pelvis. Main thoracic (MT) and thoraco-lumbar/lumbar (TL/L) Cobb angles, sagittal curves, and apical rotations were compared at the initial visit and after 2 years. Patient compliance and QoL were tracked respectively by using embedded temperature sensors and SRS-22r questionnaires. RESULTS: Forty-four patients with CAD-FEM braces and 50 with CAD braces completed the study. Average in-brace correction was 9° MT (8° CAD-FEM, 10° CAD, P = 0.054) and 12° TL/L (same for both subgroups, P = 0.91). Out-of-brace 2-year progression from initial deformity was <4° for all 3D measurements. Sixty-six percent of all cases (30 CAD-FEM, 35 CAD) met the ≤5° curve progression criterion, 83% (38 CAD-FEM, 43 CAD) stayed <45°, and 6% (5 CAD-FEM, 1 CAD) underwent fusion surgery. 3D correction, compliance, and QoL were not significantly different between both subgroups (P > 0.05). CONCLUSION: After 2 years, patients with braces designed using CAD/CAM with/without FEM had satisfying clinical outcomes (compared to the BrAIST study), 3D corrections, compliance and QoL. A more comprehensive optimization of brace treatment remains to be accomplished. LEVEL OF EVIDENCE: 2.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Guy A, Labelle H, Barchi S, et al. Braces Designed Using CAD/CAM Combined or Not With Finite Element Modeling Lead to Effective Treatment and Quality of Life After 2 Years: A Randomized Controlled Trial. Spine (Phila Pa 1976). 2021. PMID: 32991513. doi:10.1097/BRS.0000000000003705

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。