文献速递关节外科创伤骨科

假体周围骨折合并髋膝关节假体周围感染:血清与滑液标志物的诊断价值

Concomitant Hip and Knee Periprosthetic Joint Infection in Periprosthetic Fracture: Diagnostic Utility of Serum and Synovial Fluid Markers.
PubMed 文献 · J Arthroplasty · 2020-08-18

本研究纳入144例连续患者,其中41例假体周围骨折合并假体周围感染(PJI)、103例单纯假体周围骨折,评估血清ESR、CRP及滑液WBC计数、多形核百分比对PJI的诊断效能。结果显示各标志物诊断效用低于单纯PJI场景,按MSIS阈值ESR、CRP和WBC计数敏感性高但特异性低。

要点

  • 滑液WBC计数AUC为0.90,最佳阈值4552 cells/μL(敏感性86%、特异性85%)。
  • 按MSIS阈值,ESR敏感性87%、特异性48%;CRP敏感性94%、特异性40%。
  • 所有标志物联合AUC为0.90,敏感性84%、特异性79%。

核心结论

  • 在假体周围骨折合并PJI的情况下,血清和滑液标志物的诊断效用低于单纯PJI。
  • 使用MSIS阈值时,ESR、CRP和WBC计数敏感性高但特异性低,应考虑提高阈值并联合使用所有血清和滑液标志物。

研究设计与样本

  • 纳入144例连续患者:41例假体周围骨折合并PJI,103例单纯假体周围骨折。
  • 评估血清ESR、CRP及滑液WBC计数、多形核百分比的诊断性能。

主要发现

  • ESR按MSIS阈值敏感性87%、特异性48%,AUC 0.74;最佳阈值45.5 mm/h时敏感性76%、特异性68%。
  • CRP敏感性94%、特异性40%,AUC 0.68;最佳阈值16.7 mg/L时敏感性84%、特异性51%。
  • 滑液WBC计数敏感性87%、特异性78%,AUC 0.90;最佳阈值4552 cells/μL时敏感性86%、特异性85%。
  • 多形核百分比敏感性79%、特异性63%,AUC 0.70;最佳阈值79.5%时敏感性74%、特异性63%。
  • 所有标志物联合AUC 0.90,敏感性84%、特异性79%。

关键数值与推荐

  • ESR按MSIS阈值敏感性87%、特异性48%,AUC 0.74,最佳阈值45.5 mm/h(敏感性76%、特异性68%)。
  • CRP敏感性94%、特异性40%,AUC 0.68,最佳阈值16.7 mg/L(敏感性84%、特异性51%)。
  • 滑液WBC计数敏感性87%、特异性78%,AUC 0.90,最佳阈值4552 cells/μL(敏感性86%、特异性85%)。
  • 多形核百分比敏感性79%、特异性63%,AUC 0.70,最佳阈值79.5%(敏感性74%、特异性63%)。
  • 所有标志物联合AUC 0.90,敏感性84%、特异性79%。

临床怎么用

  • 作者认为,在假体周围骨折合并PJI时,应考虑提高血清和滑液标志物的阈值并联合使用所有标志物进行诊断。
  • 原文未据此给出其他推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Diagnosing periprosthetic joint infection (PJI) in patients with a periprosthetic fracture can be challenging due to concerns regarding the reliability of commonly used serum and synovial fluid markers. This study aimed at determining the diagnostic performance of serum and synovial fluid markers for diagnosing PJI in patients with a periprosthetic fracture of a total joint arthroplasty. METHODS: A total of 144 consecutive patients were included: (1) 41 patients with concomitant PJI and periprosthetic fracture and (2) 103 patients with periprosthetic fracture alone. Serum markers erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), and synovial markers white blood cell (WBC) count and polymorphonuclear percentage were assessed. RESULTS: ESR demonstrated 87% sensitivity and 48% specificity at the Musculoskeletal Infection Society threshold, area under the curve (AUC) of 0.74, and optimal threshold of 45.5 mm/h (76% sensitivity, 68% specificity). CRP showed 94% sensitivity and 40% specificity, AUC of 0.68 with optimal threshold of 16.7 mg/L (84% sensitivity, 51% specificity). Synovial WBC count demonstrated 87% sensitivity and 78% specificity, AUC of 0.90 with optimal threshold of 4552 cells/μL (86% sensitivity, 85% specificity). Polymorphonuclear percentage showed 79% sensitivity and 63% specificity, AUC of 0.70 with optimal threshold of 79.5% (74% sensitivity, 63% specificity). The AUC of all combined markers was 0.90 with 84% sensitivity and 79% specificity. CONCLUSION: The diagnostic utility of the serum and synovial markers for diagnosing PJI was lower in the setting of concomitant periprosthetic fracture compared to PJI alone. Using the Musculoskeletal Infection Society thresholds, ESR, CRP, and WBC count showed high sensitivity, yet low specificity, thus higher thresholds and utilizing all serum and synovial markers in combination should be considered.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. van den Kieboom J, Tirumala V, Xiong L, et al. Concomitant Hip and Knee Periprosthetic Joint Infection in Periprosthetic Fracture: Diagnostic Utility of Serum and Synovial Fluid Markers. J Arthroplasty. 2020. PMID: 32893059. doi:10.1016/j.arth.2020.08.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。