文献速递运动医学关节外科

温敏性防粘连剂对单排关节镜下肩袖修复的影响

Effects of a Thermosensitive Antiadhesive Agent on Single-Row Arthroscopic Rotator Cuff Repair.
PubMed 文献 · Am J Sports Med · 2020-08-14

该队列研究比较了296例关节镜下肩袖修复患者中,112例接受温敏凝胶防粘连剂注射与184例未注射对照的结局。注射组再撕裂率显著低于对照组(17.9% vs 28.8%,P=0.034),术后僵硬发生率无显著差异(P=0.710),但功能评分结果相互矛盾,注射组12个月疼痛相关评分较差。

要点

  • 注射组再撕裂率17.9%(20/112)显著低于对照组28.8%(53/184),P=0.034。
  • 术后僵硬发生率两组无显著差异(P=0.710)。
  • 功能评分结果矛盾:对照组疼痛VAS、ASES和SST评分更优,注射组Constant-Murley评分更优。

核心结论

  • 接受防粘连剂组的肌腱愈合率显著高于对照组。
  • 术后僵硬发生率两组间无差异。
  • 注射组12个月疼痛相关功能评分结果较差。
  • 防粘连剂在肩袖修复中的生物学作用应进一步评估。

研究设计与样本

  • 队列研究,证据等级3级。
  • 在296例接受关节镜下肩袖修复手术的患者中,比较向肩峰下间隙注射温敏凝胶防粘连剂者112例与未注射对照者184例的结局。
  • 再撕裂率通过术后1年磁共振成像确定,并连续评估肩关节活动度和功能评分。

主要发现

  • 注射组再撕裂率为17.9%(20/112),对照组为28.8%(53/184),注射组显著低于对照组(P=0.034)。
  • 术后僵硬两组间无显著差异(P=0.710)。
  • 活动度数据中仅术后6个月前屈在注射组显示更优结果。
  • 疼痛视觉模拟评分对照组优于注射组(注射组vs对照组:6个月2.17 vs 1.68;12个月1.82 vs 1.28)。
  • 美国肩肘外科医师评分12个月对照组89.64优于注射组79.89,简单肩关节测试评分12个月对照组10.06优于注射组8.70;Constant-Murley评分注射组优于对照组(注射组vs对照组:3个月59.49 vs 55.60;6个月77.35 vs 71.98;12个月87.28 vs 81.56)。

关键数值与推荐

  • 再撕裂率:注射组17.9%(20/112)vs对照组28.8%(53/184),P=0.034。
  • 术后僵硬发生率两组比较P=0.710。
  • 疼痛视觉模拟评分注射组vs对照组:6个月2.17 vs 1.68;12个月1.82 vs 1.28。
  • 美国肩肘外科医师评分12个月注射组79.89 vs对照组89.64;简单肩关节测试评分12个月注射组8.70 vs对照组10.06。
  • Constant-Murley评分注射组vs对照组:3个月59.49 vs 55.60;6个月77.35 vs 71.98;12个月87.28 vs 81.56。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出防粘连剂在肩袖修复中的生物学作用应进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Postoperative stiffness after rotator cuff repair is a common complication that can lead to poor outcomes and patient discomfort. The application of an antiadhesive agent at the time of repair recently became an option for clinicians, but little information is available on its effects. PURPOSE: To evaluate and compare retear rates, the incidence of postoperative stiffness, and the clinical outcomes of patients who underwent cuff repair with or without the application of an antiadhesive agent. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Among 296 patients who underwent arthroscopic rotator cuff repair surgery, we compared the outcomes of those injected with a thermosensitive gel antiadhesive agent into the subacromial space (112 cases) versus noninjected controls (184 cases). Retear rates in the 2 groups were determined by magnetic resonance imaging at 1 year after surgery. Shoulder joint range of motion and functional scores were evaluated serially. RESULTS: The rate of retear was significantly lower in the injection group (20/112 cases; 17.9%) than the control group (53/184 cases; 28.8%) (P = .034). Postoperative stiffness was not significantly different between the 2 groups (P = .710). Among the data regarding range of motion, only forward flexion at 6 months after surgery showed superior results in the injection group. Functional scores showed conflicting results: The control group had better visual analog scale scores for pain (injection vs control: 2.17 vs 1.68 at 6 months; 1.82 vs 1.28 at 12 months), American Shoulder and Elbow Surgeons scores (79.89 vs 89.64 at 12 months), and simple shoulder test scores (8.70 vs 10.06 at 12 months), whereas the injection group had better Constant-Murley scores (injection vs control: 59.49 vs 55.60 at 3 months; 77.35 vs 71.98 at 6 months; 87.28 vs 81.56 at 12 months). CONCLUSION: The tendon healing rate was significantly higher in the group receiving an antiadhesive agent than in the control group. No intergroup difference was seen in the occurrence of postoperative stiffness. However, the pain-related functional score showed inferior results in the injection group at 12 months. The biological action of antiadhesive agents in rotator cuff repair should be further evaluated.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Kim J, Kim Y, Jung W, et al. Effects of a Thermosensitive Antiadhesive Agent on Single-Row Arthroscopic Rotator Cuff Repair. Am J Sports Med. 2020. PMID: 32795189. doi:10.1177/0363546520946088

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。