文献速递运动医学关节外科

关节镜下肩袖修复术后肱二头肌长头腱会发生什么变化

What happens to the long head of the biceps tendon after arthroscopic rotator cuff repair?
PubMed 文献 · Bone Joint J · 2020-01-01

研究纳入162例保留肱二头肌长头腱(LHBT)的孤立性冈上肌腱修复患者,测量术前与术后至少12个月MRI上结节间沟内LHBT横截面积(CSA),并评估腱内信号改变、断裂、脱位或上盂唇病变。术后CSA(12.5 mm²(SD 8.3))显著大于术前(11.5 mm²(SD 7.5);p=0.005),32例(19.8%)患者在肩袖修复术后24个月出现未处理LHBT的形态学改变,术前LHBT在沟内偏心位置是与术后改变相关的主要因素(单因素p=0.011;多因素p=0.011)。

要点

  • 肩袖修复术后结节间沟内LHBT的CSA较术前增大(12.5 mm²(SD 8.3) vs 11.5 mm²(SD 7.5);p=0.005)。
  • 32例(19.8%)患者在术后24个月出现未处理LHBT的形态学改变。
  • 术前MRI显示LHBT在沟内偏心位置与术后LHBT改变相关(单因素p=0.011;多因素p=0.011)。

核心结论

  • 肩袖修复术后肱二头肌沟内LHBT的CSA增加,术前LHBT偏心位置与术后腱本身进一步改变相关。

研究设计与样本

  • 纳入162例接受孤立性冈上肌腱修复并保留LHBT的患者进行队列评估,测量术前及术后至少12个月MRI上结节间沟内LHBT的CSA,并评估术后LHBT腱内信号改变、断裂、脱位或上盂唇病变及相关因素。

主要发现

  • 术后LHBT的CSA为12.5 mm²(SD 8.3),显著大于术前的11.5 mm²(SD 7.5)(p=0.005)。
  • 32例患者(19.8%)在肩袖修复术后24个月出现未处理LHBT的形态学改变。
  • 单因素回归分析显示与LHBT状态改变主要相关的因素是术前MRI上LHBT在沟内偏心位置(p=0.011)。
  • 多因素logistic回归分析也显示LHBT偏心位置是与术后未处理LHBT改变相关的因素(p=0.011)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The purpose of this study was to identify the changes in untreated long head of the biceps brachii tendon (LHBT) after a rotator cuff tear and to evaluate the factors related to the changes. METHODS: A cohort of 162 patients who underwent isolated supraspinatus with the preservation of LHBT was enrolled and evaluated. The cross-sectional area (CSA) of the LHBT on MRI was measured in the bicipital groove, and preoperative to postoperative difference was calculated at least 12 months postoperatively. Second, postoperative changes in the LHBT including intratendinous signal change, rupture, dislocation, or superior labral lesions were evaluated with seeking of factors that were correlated with the changes or newly developed lesions after rotator cuff repair. RESULTS: The postoperative CSA (12.5 mm2 (SD 8.3) was significantly larger than preoperative CSA (11.5 mm2 (SD 7.5); p = 0.005). In total, 32 patients (19.8%) showed morphological changes in the untreated LHBT 24 months after rotator cuff repair. Univariate regression analysis revealed that the factor chiefly related to the change in LHBT status was an eccentric LHBT position within the groove found on preoperative MRI (p = 0.011). Multivariate analysis using logistic regression also revealed that an eccentric LHBT position was a factor related to postoperative change in untreated LHBTs (p = 0.011). CONCLUSION: The CSA of the LHBT inside the biceps groove increased after rotator cuff repair. The preoperative presence of an eccentrically positioned LHBT was associated with further changes of the tendon itself after rotator cuff repair. Cite this article: Bone Joint J 2020;102-B(9):1194-1199.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Lee HJ, Kim ES, Kim YS, et al. What happens to the long head of the biceps tendon after arthroscopic rotator cuff repair? Bone Joint J. 2020. PMID: 32862691. doi:10.1302/0301-620X.102B9.BJJ-2020-0076.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。