文献速递运动医学关节外科

髋关节吸附密封,第一部分:髋臼盂唇高度对髋关节牵张稳定性的作用

The Hip Suction Seal, Part I: The Role of Acetabular Labral Height on Hip Distractive Stability.
PubMed 文献 · Am J Sports Med · 2020-08-07

研究采用12例符合纳入标准的冷冻尸体半骨盆,在髋关节以0.5 mm/s牵张时记录最大牵张力、至吸附密封破裂距离和峰值负压,发现髋臼盂唇高度与吸附密封参数相关,盂唇高度小于6 mm与至破裂距离更短和峰值负压更低相关。

要点

  • 髋臼盂唇高度与最大牵张力、至吸附密封破裂距离和峰值负压相关。
  • 盂唇高度小于6 mm的髋关节至吸附密封破裂距离和峰值负压均显著低于盂唇大于6 mm者。
  • 作者认为对盂唇较小的患者,增加盂唇尺寸的策略如盂唇增强可能合理。

核心结论

  • 髋臼盂唇高度较小(小于6 mm)与至吸附密封破裂距离缩短和峰值负压降低显著相关。
  • 作者认为,对盂唇较小的患者,采用增加盂唇尺寸的新策略(如盂唇增强)以优化髋关节吸附密封可能是合理的。

研究设计与样本

  • 描述性实验室研究,使用23具新鲜冷冻尸体半骨盆,最终12例髋符合纳入标准。
  • 排除髋臼发育不良或股骨髋臼撞击相关骨形态特征、关节内病变或无可测量吸附密封的髋关节。
  • 测试前移除髋关节囊,关节内放置压力传感器,髋关节固定于加热盐水浴中,用数字卡尺测量盂唇尺寸。
  • 髋关节以0.5 mm/s速率牵张,记录最大牵张力、至吸附密封破裂距离和峰值负压。
  • 采用Spearman rho分析相关性,Mann-Whitney U检验检测组间差异。

主要发现

  • 12例髋中,最大牵张力与峰值负压显著相关(R=-0.83;P=.001)。
  • 盂唇高度与最大牵张力相关(R=0.69,P=.013),与至吸附密封破裂距离相关(R=0.55,P=.063),与峰值负压相关(R=-0.62,P=.031)。
  • 盂唇高度小于6 mm见于5例髋,平均高度6.48 mm(SD,2.65 mm;范围,2.62-11.90 mm;95%CI,4.80-8.17 mm)。
  • 与7例盂唇较大(大于6 mm)的髋相比,盂唇较小的髋至吸附密封破裂距离显著更短(中位数,2.3 vs 7.2 mm;P=.010),峰值负压显著降低(中位数,-59.3 vs -66.9 kPa;P=.048)。

临床怎么用

  • 作者认为,对盂唇较小的患者,采用增加盂唇尺寸的新策略(如盂唇增强)以优化髋关节吸附密封可能是合理的。
  • 需要进一步研究以明确盂唇高度对髋关节稳定性的临床影响。

局限性

  • 需要进一步研究以明确盂唇高度对髋关节稳定性的临床影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The acetabular labrum has been found to provide a significant contribution to the distractive stability of the hip. However, the influence of labral height on hip suction seal biomechanics is not known. HYPOTHESIS: The smaller height of acetabular labrum is associated with decreased distractive stability. STUDY DESIGN: Descriptive laboratory study. METHODS: A total of 23 fresh-frozen cadaveric hemipelvises were used in this study. Hips with acetabular dysplasia or femoroacetabular impingement-related bony morphologic features, intra-articular pathology, or no measurable suction seal were excluded. Before testing, each specimen's hip capsule was removed, a pressure sensor was placed intra-articularly, and the hip was fixed in a heated saline bath. Labral size was measured by use of a digital caliper. Maximum distraction force, distance to suction seal rupture, and peak negative pressure were recorded while the hip underwent distraction at a rate of 0.5 mm/s. Correlations between factors were analyzed using the Spearman rho, and differences between groups were detected using Mann-Whitney U test. RESULTS: Of 23 hips, 12 satisfied inclusion criteria. The maximum distraction force and peak negative pressure were significantly correlated (R = -0.83; P = .001). Labral height was largely correlated with all suction seal parameters (maximum distraction force, R = 0.69, P = .013; distance to suction seal rupture, R = 0.55, P = .063; peak negative pressure, R = -0.62, P = .031). Labral height less than 6 mm was observed in 5 hips, with a mean height of 6.48 mm (SD, 2.65 mm; range, 2.62-11.90 mm; 95% CI, 4.80-8.17 mm). Compared with the 7 hips with larger labra (>6 mm), the hips with smaller labra had significantly shorter distance to suction seal rupture (median, 2.3 vs 7.2 mm; P = .010) and significantly decreased peak negative pressure (median, -59.3 vs -66.9 kPa; P = .048). CONCLUSION: Smaller height (<6 mm) of the acetabular labrum was significantly associated with decreased distance to suction seal rupture and decreased peak negative pressure. A new strategy to increase the size of the labrum, such as labral augmentation, could be justified for patients with smaller labra in order to optimize the hip suction seal. CLINICAL RELEVANCE: The height of the acetabular labrum is correlated with hip suction seal biomechanics. Further studies are required to identify the clinical effects of labral height on hip stability.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Storaci HW, Utsunomiya H, Kemler BR, et al. The Hip Suction Seal, Part I: The Role of Acetabular Labral Height on Hip Distractive Stability. Am J Sports Med. 2020. PMID: 32762634. doi:10.1177/0363546520941855

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。