保留足够髋臼深度的意义:钳型形态患者髋关节镜术后2年结果与匹配对照相当
前瞻性队列研究比较钳型股髋撞击(LCEA>40°)与正常覆盖(LCEA 25°-40°)患者髋关节镜术后2年患者报告结果,钳型组LCEA从44.0°±2.8°降至34.2°±3.5°,对照组从32.9°±3.9°降至31.0°±3.0°,两组iHOT-12均改善35.7分(P=0.9)、非关节炎髋评分均改善22.3分(P=0.6),结论为髋臼过度覆盖的关节镜处理可获得与其他原因股髋撞击关节镜相当的优良结果。
要点
- 钳型组LCEA从44.0°±2.8°降至34.2°±3.5°,对照组从32.9°±3.9°降至31.0°±3.0°。
- 两组iHOT-12均改善35.7分(P=0.9),非关节炎髋评分均改善22.3分(P=0.6)。
- 钳型组与对照组2年随访率分别为2.5%与2.6%,全髋关节置换转化率分别为1.2%与0.3%。
核心结论
- 髋臼过度覆盖的关节镜处理可获得优良结果,与其他原因症状性股髋撞击的关节镜结果相当。
- 关键发现是较小的髋臼缘切除产生平均术后LCEA 34.2°且标准差较小。
研究设计与样本
- 队列研究,证据等级3。
- 数据前瞻性收集自单一位外科医生行股髋撞击髋关节镜术后至少2年随访的患者。
- 钳型形态(LCEA>40°)按性别、年龄、软骨损伤和手术日期以1:1比例与LCEA 25°至40°的对照匹配。
- 手术目标为以最小髋臼缘切除将LCEA降至正常范围上限,通常为35°至37°。
主要发现
- 钳型组114髋(93例)从对照组616髋(541例)中1:1匹配。
- 钳型组平均±标准差年龄34.5±12.2岁,与对照组在年龄、体重指数或随访时间上无差异。
- 钳型组LCEA从44.0°±2.8°降至34.2°±3.5°,对照组从32.9°±3.9°降至31.0°±3.0°。
- iHOT-12两组均改善35.7分(方差分析交互作用P=0.9),非关节炎髋评分均改善22.3分(P=0.6)。
- 全部合格手术中,钳型组与对照组2年随访率分别为2.5%与2.6%,全髋关节置换转化率分别为1.2%与0.3%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patients with pincer-type femoroacetabular impingement are commonly treated with arthroscopic reduction of acetabular depth as measured by the lateral center-edge angle (LCEA). The optimal amount of rim reduction has not been established, although large resections may increase contact pressures through the hip. A recent publication demonstrated inferior surgical outcomes in patients with acetabular overcoverage as compared with normal acetabular coverage. Casual observation of our database suggested equivalent improvements, prompting a similar analysis. PURPOSE: To analyze patient-reported outcomes after hip arthroscopy for femoroacetabular impingement in patients with acetabular overcoverage who were matched with controls with normal coverage, as well as to analyze associations with reduction in LCEA. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Data were collected prospectively from patients with a minimum 2-year follow-up after receiving hip arthroscopy for femoroacetabular impingement by a single surgeon. Cases were reviewed to identify those with pincer-type morphology (LCEA >40°) and matched according to sex, age, chondral damage, and surgery date in a 1:1 ratio with controls with an LCEA of 25° to 40°. The surgical goal was to reduce the LCEA to the upper end of the normal range with minimal rim resection, usually 35° to 37°. Radiographic measurements of coverage, intraoperative findings, procedures, and patient-reported outcomes were recorded, including the 12-Item International Hip Outcome Tool, Non-arthritic Hip Score, Hip Disability and Osteoarthritis Outcome Score, visual analog scale for pain, rates of revision or reoperation, and conversion to total hip arthroplasty. RESULTS: A total of 114 hips (93 patients) for the pincer group were matched 1:1 from 616 hips (541 patients) for the control group. The pincer group (mean ± SD age, 34.5 ± 12.2 years) did not differ in age, body mass index, or follow-up from controls. LCEA was reduced in both groups pre- to postoperatively: the pincer group from 44.0° ± 2.8° to 34.2° ± 3.5° and the controls from 32.9° ± 3.9° to 31.0° ± 3.0°. No differences in improvement were observed: iHOT-12 improved by 35.7 points in both groups (P = .9 for analysis of variance interaction) and Nonarthritic Hip Score by 22.3 points (P = .6). From all eligible surgical procedures, 2-year follow up rates were 2.5% and 2.6% for the pincer and control cohorts, respectively, and 1.2% and 0.3% for conversion to total hip arthroplasty. CONCLUSION: Arthroscopic management of acetabular overcoverage can achieve excellent results, equivalent to arthroscopy for other causes of symptomatic femoroacetabular impingement. A key finding was smaller rim resections producing a mean postoperative LCEA of 34.2° with a small standard deviation.
引用
- Brick CR, Bacon CJ, Brick MJ, et al. Importance of Retaining Sufficient Acetabular Depth: Successful 2-Year Outcomes of Hip Arthroscopy for Patients With Pincer Morphology as Compared With Matched Controls. Am J Sports Med. 2020. PMID: 32736507. doi:10.1177/0363546520937301
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。