非骨水泥钽金属组件与骨水泥胫骨组件在全膝关节置换术中的比较:一项单盲随机对照试验的11至15年结局
这项单盲随机对照试验将90例70岁以下症状性膝骨关节炎患者随机分配至非骨水泥钽金属胫骨单块组件组或标准骨水泥模块化组件组,两组均使用同一后交叉韧带保留型全膝关节系统及非骨水泥股骨组件。末次随访时(术后11至15年),非骨水泥组在牛津膝关节评分和膝关节学会评分上较骨水泥组有统计学和临床显著改善(p=0.001),影像学评估也更优(p<0.001),但SF-12全局评分无统计学差异(p=0.812);骨水泥组无翻修,非骨水泥组因骨折翻修1例,两组15年生存率均优异。
要点
- 非骨水泥钽金属胫骨组件组在牛津膝关节评分和膝关节学会评分上较骨水泥组有统计学和临床显著改善(p=0.001)。
- 非骨水泥组影像学评估优于骨水泥组(p<0.001),但SF-12全局评分无统计学差异(p=0.812)。
- 骨水泥组无翻修,非骨水泥组因骨折翻修1例;两组15年生存率均优异。
核心结论
- 与匹配设计的骨水泥胫骨组件相比,使用非骨水泥骨小梁金属胫骨植入物可获得更好的长期临床结局,但两者在植入后长达15年均具有优异的生存率。
研究设计与样本
- 单盲随机对照试验,纳入70岁以下症状性膝骨关节炎患者,随机接受非骨水泥钽金属胫骨单块组件或标准骨水泥模块化组件,两组均使用同一后交叉韧带保留型全膝关节系统、非骨水泥股骨组件且不行髌骨置换。
- 共随机90膝,末次随访评估77膝;11例患者死亡,2例失访;末次随访时骨水泥组41膝、非骨水泥组36膝;招募时平均年龄63岁(50至70),男性46膝(51.1%),平均体重指数30.4 kg/m2(21至36)。
主要发现
- 末次随访时所有患者处于术后11至15年;骨水泥组无翻修,非骨水泥组因骨折翻修1例。
- 非骨水泥组在牛津膝关节评分和膝关节学会评分上较骨水泥组有统计学和临床显著改善(p=0.001)。
- SF-12全局评分两组无统计学差异(p=0.812)。
- 非骨水泥组影像学分析优于骨水泥组(p<0.001)。
关键数值与推荐
- 非骨水泥组牛津膝关节评分和膝关节学会评分较骨水泥组有统计学和临床显著改善(p=0.001)。
- SF-12全局评分两组无统计学差异(p=0.812)。
- 非骨水泥组影像学分析优于骨水泥组(p<0.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. METHODS: Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m2 (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. RESULTS: At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). CONCLUSION: Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025-1032.
引用
- Hampton M, Mansoor J, Getty J, et al. Uncemented tantalum metal components versus cemented tibial components in total knee arthroplasty: 11- to 15-year outcomes of a single-blinded randomized controlled trial. Bone Joint J. 2020. PMID: 32731836. doi:10.1302/0301-620X.102B8.BJJ-2019-1448.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。