文献速递关节外科创伤骨科

使用带三头肌的同种异体近端尺骨移植翻修肘关节置换术治疗合并尺骨骨缺损与三头肌功能不全

Revision Elbow Arthroplasty Using a Proximal Ulnar Allograft with Allograft Triceps for Combined Ulnar Bone Loss and Triceps Insufficiency.
PubMed 文献 · J Bone Joint Surg Am · 2020-01-01

2010年至2017年间,资深作者对10例合并结构性近端尺骨骨缺损与三头肌功能不全的翻修肘关节置换术患者,采用带完整三头肌腱的同种异体近端尺骨与尺骨假体组合为同种异体-假体复合体(APC)进行重建,并将剩余三头肌修复至三头肌同种异体移植物。平均随访45个月(范围24至76个月),所有肘关节疼痛改善,平均屈伸弧95°,平均Mayo肘关节性能评分为76分(范围45至95分),平均三头肌肌力评分为4分,8例尺骨重建完整的肘关节中无尺骨假体放射学松动且尺骨移植物均愈合,但出现6例再手术。

要点

  • 带三头肌的同种异体近端尺骨APC可同时重建近端尺骨骨缺损与伸肘装置。
  • 10例翻修肘中平均随访45个月,疼痛均改善,平均MEPS为76分。
  • 6例再手术:肱骨松动3例、深部感染1例、尺骨移植物骨折1例、伤口清创缝合1例。

核心结论

  • 对于肘关节置换失败合并结构性尺骨骨缺损和三头肌功能不全者,使用带保留三头肌腱的结构性近端尺骨同种异体移植物作为APC重建近端尺骨和三头肌可有效完成重建,但该手术与复杂翻修肘关节置换术一样伴有预期的高再手术率。

研究设计与样本

  • 回顾性病例系列,2010年至2017年间由资深作者实施10例翻修肘关节置换术,采用带完整三头肌腱的同种异体近端尺骨与尺骨假体组合为APC,剩余三头肌修复至三头肌同种异体移植物,术后所有肘关节伸直位制动6周,平均随访45个月(范围24至76个月)。

主要发现

  • 翻修肘关节置换术使所有肘关节在10分视觉模拟量表上疼痛改善。
  • 平均屈伸弧为95°,平均Mayo肘关节性能评分为76分(范围45至95分),平均三头肌肌力评分为4分。
  • 共6例再手术:3例因肱骨松动,1例因深部感染,1例因尺骨同种异体移植物骨折,1例因伤口清创和缝合。
  • 8例尺骨重建完整的肘关节中,无尺骨假体放射学松动,8例尺骨移植物被认为放射学完整且愈合。

关键数值与推荐

  • 翻修手术指征包括:无菌性松动4肘,假体周围尺骨骨折伴假体松动2肘,二期再植入的第二阶段4肘。
  • 2例肘关节因相关结构性肱骨骨缺损还需行肱骨APC。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: When revision elbow arthroplasty is required in the presence of structural proximal ulnar bone loss and triceps insufficiency, structural ulnar bone-grafting and triceps reconstruction are both required to reconstruct the skeleton and to restore active extension. We have developed a technique utilizing a structural proximal ulnar allograft with its attached triceps as an allograft-prosthetic composite (APC) to provide reconstruction of the proximal ulnar bone and deficient extensor mechanism with the same allograft. METHODS: Between 2010 and 2017, the senior author performed 10 revision elbow arthroplasties using a proximal ulnar allograft with its intact triceps tendon allograft. The allograft ulna was combined with an ulnar component in an APC fashion, whereas the remaining triceps was repaired to the triceps allograft. Indications for a revision surgical procedure included aseptic loosening in 4 elbows, periprosthetic ulnar fracture with component loosening in 2 elbows, and the second stage of a 2-stage reimplantation in 4 elbows. Two elbows also required humeral APCs due to associated structural humeral bone loss. Postoperatively, all elbows were immobilized in extension for 6 weeks. The mean follow-up time was 45 months (range, 24 to 76 months). RESULTS: Revision elbow arthroplasty resulted in pain improvement in all elbows in a 10-point visual analog scale. The mean flexion-extension arc was 95°, the mean Mayo Elbow Performance Score was 76 points (range, 45 to 95 points), and the mean triceps strength score was 4. There were 6 reoperations: 3 for humeral loosening, 1 for deep infection, 1 for fracture of the ulnar allograft, and 1 for wound debridement and closure. For the 8 elbows with an intact ulnar reconstruction, no ulnar components were radiographically loose, and the ulnar graft was considered radiographically intact and healed in 8 elbows. CONCLUSIONS: Reconstruction of the proximal part of the ulna and triceps in failed elbow arthroplasties with structural ulnar bone loss can be effectively accomplished using a structural proximal ulnar allograft as an APC with the preserved triceps tendon for the extensor mechanism reconstruction, but the procedure is associated with an expected high reoperation rate, as is the case in complex revision elbow arthroplasty. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Burnier M, Nguyen NTV, Morrey ME, et al. Revision Elbow Arthroplasty Using a Proximal Ulnar Allograft with Allograft Triceps for Combined Ulnar Bone Loss and Triceps Insufficiency. J Bone Joint Surg Am. 2020. PMID: 32852355. doi:10.2106/JBJS.20.00414

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。