长柄非骨水泥型单体柄用于全髋关节翻修术的中期临床与影像学结果
这项多中心回顾性队列研究纳入335例接受Corail翻修柄全髋关节翻修术的成人,最终201例完成至少5年随访。Kaplan-Meier生存率:任何组件因任何原因再翻修93.9%,柄因任何原因再翻修96.7%,柄因无菌原因再翻修99.3%;末次随访Harris髋关节评分84.8±13.1,Oxford髋关节评分21.0±7.8,Engh评分16.4±6.7。作者结论认为该长锥形非骨水泥翻修柄在至少5年随访时取得了优异的临床与影像学结果。
要点
- 最终201例随访至少5年,Harris髋关节评分84.8±13.1,Oxford髋关节评分21.0±7.8。
- 柄因任何原因再翻修Kaplan-Meier生存率96.7%,柄因无菌原因再翻修99.3%。
- 任何组件因任何原因再翻修Kaplan-Meier生存率93.9%。
核心结论
- 作者结论认为该长锥形非骨水泥翻修柄在至少5年随访时取得了优异的临床与影像学结果,羟基磷灰石涂层促进骨整合,即使在广泛骨缺损的股骨中也是如此。
研究设计与样本
- 多中心回顾性队列研究,回顾性分析2000年至2012年间335例接受Corail翻修柄(DePuy, Leeds, UK)全髋关节翻修术的成人连续病例。
- 最终队列为201例患者,翻修手术时年龄70±12岁,体重指数26±4。
- 证据等级为IV级,回顾性队列研究。
主要发现
- 77例患者带翻修柄死亡,47例无法联系,22例发生柄再翻修,最终纳入201例。
- Kaplan-Meier生存率:任何组件因任何原因再翻修93.9%,柄因任何原因再翻修96.7%,柄因无菌原因再翻修99.3%。
- 末次随访Harris髋关节评分为84.8±13.1,Oxford髋关节评分为21.0±7.8,Engh评分为16.4±6.7。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: For the past 2 decades, the authors have been using a long tapered cementless stem made of titanium and fully coated with hydroxyapatite for revision total hip arthroplasty. The purpose of this multicentric study is to assess clinical outcomes, radiographic outcomes, re-revision rates, and survival rates of this revision stem at a minimum 5-year follow-up. METHODS: The records of a multicentric continuous series of 335 adults undergoing revision total hip arthroplasty using the Corail revision stem (DePuy, Leeds, UK) between 2000 and 2012 were retrospectively reviewed. The Harris Hip Score, Oxford Hip Score, and Engh score were recorded. Survival was assessed using the Kaplan-Meier method and cumulative incidence function. RESULTS: Seventy-seven patients died with their revision stem in place, 47 could not be contacted, and 22 had stem re-revisions. This left a final cohort of 201 patients, aged 70 ± 12 years at revision surgery, with a body mass index of 26 ± 4. The Kaplan-Meier survival was 93.9% for re-revision of any component for any reason, 96.7% for re-revision of the stem for any reason, and 99.3% for re-revision of the stem for aseptic reasons. At last follow-up, the Harris Hip Score was 84.8 ± 13.1, the Oxford Hip Score was 21.0 ± 7.8, and the Engh score was 16.4 ± 6.7. CONCLUSION: The long tapered cementless revision stem had excellent clinical and radiographic outcomes at a minimum follow-up of 5 years. The revision stem enabled restoration of bone stock in femurs with pre-revision bone defects, confirming that the hydroxyapatite coating promotes osseointegration, even in femurs with extensive bone loss. LEVEL OF EVIDENCE: Level IV, retrospective cohort study.
引用
- Chatelet JC, Ait-Si-Selmi T, Machenaud A, et al. Mid-Term Clinical and Radiographic Outcomes of a Long Cementless Monobloc Stem for Revision Total Hip Arthroplasty. J Arthroplasty. 2020. PMID: 32819781. doi:10.1016/j.arth.2020.07.057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。