文献速递关节外科

将内衬骨水泥固定于固定良好的髋臼假体的中远期随访

Intermediate to Long-Term Follow-up of Cementing Liners into Well-Fixed Acetabular Components.
PubMed 文献 · J Bone Joint Surg Am · 2020-01-01

本研究回顾性纳入323例翻修全髋关节置换术,将非限制性高交联聚乙烯内衬骨水泥固定于固定良好的髋臼假体,平均随访9年。内衬失败11例(3%),10年免于任何翻修生存率80%,脱位发生率为17%。作者认为该技术可提供持久固定,但术后不稳定仍是值得关注的问题。

要点

  • 骨水泥固定内衬于固定良好的髋臼假体,内衬失败率为3%,均为内衬与髋臼假体分离。
  • 10年免于任何翻修生存率为80%(95%CI 75%至84%),免于任何再手术生存率为77%(95%CI 72%至82%)。
  • 脱位发生率为17%,再手术最常见原因为脱位(占再手术的45%)。

核心结论

  • 在翻修全髋关节置换术中,将非限制性高交联聚乙烯内衬骨水泥固定于固定良好的髋臼假体,可提供持久固定,骨水泥界面失败仅3%。
  • 术后不稳定仍是值得关注的问题,但其性质为多因素所致。
  • 这些数据支持在翻修全髋关节置换术中必要时继续使用该技术。

研究设计与样本

  • 回顾性识别323例翻修全髋关节置换术,将非限制性高交联聚乙烯内衬骨水泥固定于固定良好的髋臼假体。
  • 翻修时平均年龄63岁,50%患者为女性,平均随访9年。
  • 翻修最常见指征为聚乙烯磨损和骨溶解(48%)、无菌性股骨松动(35%)和髋关节不稳定(8%)。

主要发现

  • 聚乙烯内衬失败11例(3%),所有病例均为骨水泥固定内衬与髋臼假体分离。
  • 10年免于任何翻修生存率为80%(95%CI 75%至84%),免于任何再手术生存率为77%(95%CI 72%至82%)。
  • 再手术最常见原因为脱位(占再手术的45%),脱位发生率为17%。
  • 因不稳定行翻修的髋关节相比因内衬磨损行翻修的髋关节,脱位风险显著更高(HR 2.3,95%CI 1.2至4.5;p=0.02)。
  • 带高边或面改变型内衬相比平内衬,分离风险显著更高(HR 9.0,95%CI 1.2至70.6;p=0.04)。

临床怎么用

  • 作者认为,这些数据支持在翻修全髋关节置换术中必要时继续使用将非限制性高交联聚乙烯内衬骨水泥固定于固定良好的髋臼假体的技术。
  • 证据等级为治疗性IV级。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The cementation of a new liner into a well-fixed acetabular component is common during revision total hip arthroplasty (THA) for many indications, but most commonly for lack of a modern, compatible, highly cross-linked polyethylene (HXLPE) liner. However, little is known about the intermediate-term to long-term durability of this strategy. The purpose of this study was to evaluate the implant survivorship, risk of complications, clinical outcomes, and radiographic results of cementing a new HXLPE liner into a well-fixed acetabular component. METHODS: We retrospectively identified 323 revision THAs in which a nonconstrained HXLPE liner was cemented into a well-fixed acetabular component. The mean age at the time of the revision THA was 63 years, and 50% of patients were female. The most common indications for revision THA were polyethylene wear and osteolysis (48%), aseptic femoral loosening (35%), and hip instability (8%). The mean follow-up was 9 years. RESULTS: Polyethylene liner failure occurred in 11 cases (3%). In all cases, the cemented liner dissociated from the acetabular component. At 10 years, the survivorship free from any revision was 80% (95% confidence interval [CI], 75% to 84%) and the survivorship free from any reoperation was 77% (95% CI, 72% to 82%). The most common reason for re-revision was dislocation (45% of reoperations). A dislocation occurred in 17% of cases. Hips that underwent revision for instability were significantly more likely to dislocate compared with hips that underwent revision for liner wear (hazard ratio [HR], 2.3 [95% CI, 1.2 to 4.5]; p = 0.02). Elevated rim or face-changing liners were significantly more likely to dissociate than flat liners (HR, 9.0 [95% CI, 1.2 to 70.6]; p = 0.04). CONCLUSIONS: Cementation of a nonconstrained HXLPE liner into a well-fixed acetabular component during revision THA provided durable fixation with only a small number of failures at the cement interface (3%). Instability after this procedure remains a concern, but this is multifactorial in nature. These data support the continued use of this technique, when necessary, during revision THA. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Bedard NA, Tetreault MW, Hanssen AD, et al. Intermediate to Long-Term Follow-up of Cementing Liners into Well-Fixed Acetabular Components. J Bone Joint Surg Am. 2020. PMID: 32816416. doi:10.2106/JBJS.19.01441

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。