全髋关节置换术后:股骨头假体直径32毫米或更大与既往腰椎融合患者脱位风险降低相关

Following total hip arthroplasty: femoral head component diameter of 32 mm or larger is associated with lower risk of dislocation in patients with a prior lumbar fusion.
PubMed 文献 · Bone Joint J · 2020-01-01

基于芬兰多个国家健康登记库的前瞻性回顾性队列研究,分析既往腰椎融合或椎间盘切除与全髋关节置换术后脱位或翻修风险的关系,以及股骨头假体直径对脱位或翻修风险的影响。结果显示既往腰椎融合与假体脱位风险(HR=2.393,p<0.001)和翻修风险(HR=1.528,p<0.001)增加相关;与28毫米股骨头相比,32毫米(HR=0.712,p<0.001)、36毫米(HR=0.700,p<0.001)、40毫米(HR=0.421,p<0.001)股骨头脱位风险更低,38毫米(HR=0.808,p<0.140)无统计学显著差异;38毫米(HR=1.288,p<0.001)和40毫米(HR=1.367,p<0.001)股骨头翻修风险增加。结论认为腰椎融合手术与假体脱位率和翻修风险增高相关,32毫米或更大股骨头假体在既往腰椎融合患者中与脱位风险降低相关。

要点

  • 既往腰椎融合与全髋关节置换术后假体脱位风险(HR=2.393,p<0.001)和翻修风险(HR=1.528,p<0.001)增加相关。
  • 与28毫米股骨头相比,32毫米(HR=0.712,p<0.001)、36毫米(HR=0.700,p<0.001)、40毫米(HR=0.421,p<0.001)股骨头脱位风险更低,38毫米(HR=0.808,p<0.140)无统计学显著差异。
  • 与28毫米股骨头相比,38毫米(HR=1.288,p<0.001)和40毫米(HR=1.367,p<0.001)股骨头翻修风险增加。

核心结论

  • 腰椎融合手术与髋假体脱位率增高和翻修手术风险增高相关。
  • 在既往腰椎融合患者中,32毫米或更大股骨头假体与脱位风险降低相关。

研究设计与样本

  • 数据来自芬兰多个国家健康登记库,包括芬兰关节置换登记库(FAR)作为假体相关数据的主要来源,以及其他登记库如芬兰医疗保健登记库(HILMO)、社会保险机构(SII)登记库和芬兰统计局。
  • 研究设计为前瞻性回顾性队列研究,采用Cox比例风险回归和Kaplan-Meier生存分析。

主要发现

  • 既往腰椎融合手术与假体脱位风险增加相关(HR=2.393,p<0.001)和翻修风险增加相关(HR=1.528,p<0.001)。
  • 与28毫米股骨头相比,32毫米股骨头脱位风险更低(HR=0.712,p<0.001)。
  • 与28毫米股骨头相比,36毫米股骨头脱位风险更低(HR=0.700,p<0.001)。
  • 与28毫米股骨头相比,38毫米股骨头脱位风险无统计学显著差异(HR=0.808,p<0.140)。
  • 与28毫米股骨头相比,40毫米股骨头脱位风险更低(HR=0.421,p<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: There is evidence that prior lumbar fusion increases the risk of dislocation and revision after total hip arthroplasty (THA). The relationship between prior lumbar fusion and the effect of femoral head diameter on THA dislocation has not been investigated. We examined the relationship between prior lumbar fusion or discectomy and the risk of dislocation or revision after THA. We also examined the effect of femoral head component diameter on the risk of dislocation or revision. METHODS: Data used in this study were compiled from several Finnish national health registers, including the Finnish Arthroplasty Register (FAR) which was the primary source for prosthesis-related data. Other registers used in this study included the Finnish Health Care Register (HILMO), the Social Insurance Institutions (SII) registers, and Statistics Finland. The study was conducted as a prospective retrospective cohort study. Cox proportional hazards regression and Kaplan-Meier survival analysis were used for analysis. RESULTS: Prior lumbar fusion surgery was associated with increased risk of prosthetic dislocation (hazard ratio (HR) = 2.393, p < 0.001) and revision (HR = 1.528, p < 0.001). Head components larger than 28 mm were associated with lower dislocation rates compared to the 28 mm head (32 mm: HR = 0.712, p < 0.001; 36 mm: HR = 0.700, p < 0.001; 38 mm: HR = 0.808, p < 0.140; and 40 mm: HR = 0.421, p < 0.001). Heads of 38 mm (HR = 1.288, p < 0.001) and 40 mm (HR = 1.367, p < 0.001) had increased risk of revision compared to the 28 mm head. CONCLUSION: Lumbar fusion surgery was associated with higher rate of hip prosthesis dislocation and higher risk of revision surgery. Femoral head component of 32 mm (or larger) associates with lower risk of dislocation in patients with previous lumbar fusion. Cite this article: Bone Joint J 2020;102-B(8):1003-1009.

来源:Bone Joint J,查看原文。版权归原作者所有。