类风湿关节炎患者全肘关节置换术的疗效与影响因素
该研究通过检索2003年1月至2019年3月的PubMed、MEDLINE、Cochrane Reviews和Embase,纳入38项研究共2118例全肘关节置换术(TEA),评估类风湿关节炎(RA)患者的假体失败率、失败模式、危险因素及临床性能。结果显示假体失败率为16.1%(95%CI 0.128-0.200),并发症率为24.5%(95%CI 0.203-0.293),无菌性松动是最常见失败模式(9.5%;95%CI 0.071-0.124);年轻患者和无链接设计假体与更高失败率相关。
要点
- RA患者TEA假体失败率16.1%,并发症率24.5%,均高于髋、膝关节置换术。
- 无菌性松动为最常见失败模式,发生率9.5%。
- 年轻患者和无链接假体与更高失败率相关,女性患者和无链接假体与无菌性松动相关。
核心结论
- TEA对RA患者仍可提供满意结果,但假体失败率和并发症率显著高于髋、膝关节置换术。
- 患者年龄、性别以及是否使用骨水泥固定和无链接假体可影响结局。
研究设计与样本
- 系统检索PubMed、MEDLINE、Cochrane Reviews和Embase从2003年1月至2019年3月的研究。
- 纳入38项研究共2118例TEA,平均随访80.9个月(范围8.2至156)。
- 采用Meta回归分析评估各参数与结局的关联。
- 证据等级:治疗性Level IV。
主要发现
- 假体失败率为16.1%(95%CI 0.128-0.200),并发症率为24.5%(95%CI 0.203-0.293)。
- 无菌性松动为最常见失败模式,发生率为9.5%(95%CI 0.071-0.124)。
- 术后平均活动度:屈曲131.5°(95%CI 124.2°-138.8°),伸展29.3°(95%CI 26.8°-31.9°),旋前74.0°(95%CI 67.8°-80.2°),旋后72.5°(95%CI 69.5°-75.5°)。
- 术后平均Mayo肘关节性能评分(MEPS)为89.3(95%CI 86.9-91.6)。
- Meta回归分析显示年轻患者和无链接设计假体与更高失败率相关;年轻患者与并发症增加相关,女性患者和无链接假体与无菌性松动相关。
关键数值与推荐
- 假体失败率16.1%(95%CI 0.128-0.200),并发症率24.5%(95%CI 0.203-0.293)。
- 无菌性松动发生率9.5%(95%CI 0.071-0.124)。
- 术后MEPS平均89.3(95%CI 86.9-91.6)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome. METHODS: We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome. RESULTS: A total of 38 studies including 2,118 TEAs were included in the study. The mean follow-up was 80.9 months (8.2 to 156). The implant failure and complication rates were 16.1% (95% confidence interval (CI) 0.128 to 0.200) and 24.5% (95% CI 0.203 to 0.293), respectively. Aseptic loosening was the most common mode of failure (9.5%; 95% CI 0.071 to 0.124). The mean postoperative ranges of motion (ROMs) were: flexion 131.5° (124.2° to 138.8°), extension 29.3° (26.8° to 31.9°), pronation 74.0° (67.8° to 80.2°), and supination 72.5° (69.5° to 75.5°), and the mean postoperative Mayo Elbow Performance Score (MEPS) was 89.3 (95% CI 86.9 to 91.6). The meta-regression analysis identified that younger patients and implants with an unlinked design correlated with higher failure rates. Younger patients were associated with increased complications, while female patients and an unlinked prosthesis were associated with aseptic loosening. CONCLUSION: TEA continues to provide satisfactory results for patients with RA. However, it is associated with a substantially higher implant failure and complication rates compared with hip and knee arthroplasties. The patient's age, sex, and whether cemented fixation and unlinked prosthesis were used can influence the outcome. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Joint J 2020;102-B(8):967-980.