文献速递创伤骨科

Wrightington 肘关节骨折脱位分型的信度与效度

Reliability and validity of the Wrightington classification of elbow fracture-dislocation.
PubMed 文献 · Bone Joint J · 2020-01-01

本研究采用2010至2018年间48例连续患者的X线和CT影像,由英国7名观察者(4名创伤骨科顾问、2名完成CCT的fellow、1名专科注册医师)进行盲法两次评估,间隔至少4周,分别计算观察者间与观察者内信度及与术中所见的符合率。结果显示Wrightington分型信度良好,CT较X线显著提高分型准确性。

要点

  • 观察者间kappa值:X线0.52,2D CT 0.71,2D+3D重建CT 0.73。
  • 观察者内信度中位数:X线0.75,2D CT 0.77,2D+3D重建CT 0.89。
  • CT较X线显著提高与术中所见的符合率(p=0.018和p=0.028)。

核心结论

  • Wrightington分型是用于肘关节骨折脱位的可靠且有效的分型方法。
  • CT在识别损伤模式方面显著优于X线,且观察者间与观察者内重复性良好。

研究设计与样本

  • 盲法研究,使用2010至2018年间按Wrightington分型管理的48例连续患者的X线和CT影像。
  • 由英国4名创伤骨科顾问、2名完成CCT的fellow和1名专科注册医师共7名观察者进行分型。
  • 7名观察者两次审阅术前X线和CT,间隔至少4周,X线与CT分别独立审阅。
  • 采用Fleiss和Cohen kappa系数计算观察者间与观察者内信度,采用Landis和Koch标准解读kappa值强度。
  • 通过计算与术中所见的符合百分比评估效度。

主要发现

  • 48例中,A型3例(6%),B型11例(23%),B+型16例(33%),C型16例(33%),D+型2例(4%),无D型损伤。
  • 48例均有正位和侧位X线,44例有2D CT,39例有3D重建。
  • 观察者间信度kappa值:X线0.52,2D CT 0.71,2D与3D重建CT联合0.73。
  • 观察者内信度中位数:X线0.75(IQR 0.62–0.79),2D CT 0.77(IQR 0.73–0.94),2D与3D重建联合0.89(IQR 0.77–0.93)。
  • 效度分析显示使用CT扫描时准确性显著提高(p=0.018和p=0.028)。

关键数值与推荐

  • Wrightington分型根据冠突和桡骨头受累情况将肘关节骨折脱位分为六个亚型。
  • 观察者间信度kappa值X线0.52、2D CT 0.71、2D+3D重建CT 0.73。
  • 观察者内信度中位数X线0.75(IQR 0.62–0.79)、2D CT 0.77(IQR 0.73–0.94)、2D+3D重建联合0.89(IQR 0.77–0.93)。
  • CT较X线显著提高分型准确性(p=0.018和p=0.028)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The Wrightington classification system of fracture-dislocations of the elbow divides these injuries into six subtypes depending on the involvement of the coronoid and the radial head. The aim of this study was to assess the reliability and reproducibility of this classification system. METHODS: This was a blinded study using radiographs and CT scans of 48 consecutive patients managed according to the Wrightington classification system between 2010 and 2018. Four trauma and orthopaedic consultants, two post CCT fellows, and one speciality registrar based in the UK classified the injuries. The seven observers reviewed preoperative radiographs and CT scans twice, with a minimum four-week interval. Radiographs and CT scans were reviewed separately. Inter- and intraobserver reliability were calculated using Fleiss and Cohen kappa coefficients. The Landis and Koch criteria were used to interpret the strength of the kappa values. Validity was assessed by calculating the percentage agreement against intraoperative findings. RESULTS: Of the 48 patients, three (6%) had type A injury, 11 (23%) type B, 16 (33%) type B+, 16 (33%) Type C, two (4%) type D+, and none had a type D injury. All 48 patients had anteroposterior (AP) and lateral radiographs, 44 had 2D CT scans, and 39 had 3D reconstructions. The interobserver reliability kappa value was 0.52 for radiographs, 0.71 for 2D CT scans, and 0.73 for a combination of 2D and 3D reconstruction CT scans. The median intraobserver reliability was 0.75 (interquartile range (IQR) 0.62 to 0.79) for radiographs, 0.77 (IQR 0.73 to 0.94) for 2D CT scans, and 0.89 (IQR 0.77 to 0.93) for the combination of 2D and 3D reconstruction. Validity analysis showed that accuracy significantly improved when using CT scans (p = 0.018 and p = 0.028 respectively). CONCLUSION: The Wrightington classification system is a reliable and valid method of classifying fracture-dislocations of the elbow. CT scans are significantly more accurate than radiographs when identifying the pattern of injury, with good intra- and interobserver reproducibility. Cite this article: Bone Joint J 2020;102-B(8):1041-1047.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Hamoodi Z, Singh J, Elvey MH, et al. Reliability and validity of the Wrightington classification of elbow fracture-dislocation. Bone Joint J. 2020. PMID: 32731824. doi:10.1302/0301-620X.102B8.BJJ-2020-0013.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。